Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 46: 100-104, 2000;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (45)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Martin, R. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Martin, R. F.
Related Collections
Right arrow Laboratory Management
(Clinical Chemistry. 2000;46:100-104.)
© 2000 American Association for Clinical Chemistry, Inc.


Articles

General Deming Regression for Estimating Systematic Bias and Its Confidence Interval in Method-Comparison Studies

Robert F. Martin
Background: Various forms of least-squares regression analyses are used to estimate average systematic error (bias) and its confidence interval in method-comparison studies. When assumptions that underlie a particular regression method are inappropriate for the data, errors in estimated statistics result. In this report, I present an improved method for regression analysis that is free from the usual simplifying assumptions and is generally applicable to linearly related method-comparison data.

Methods: Theoretical equations based on the Deming approach, further developed by physicists and extended herein, were applied to method-comparison data analysis. Monte Carlo simulations were used to demonstrate the validity of the new procedure and to compare its performance to ordinary linear regression (OLR) and simple Deming regression (SDR) procedures.

Results: Simulation studies included three types of data commonly encountered in method-comparison studies: (a) constant within-method SDs for both methods, (b) constant within-method CVs for both methods, and (c) neither SDs nor CVs constant for both methods. For all cases examined, OLR produced unreliable confidence intervals of the estimated bias. However, OLR point estimates of systematic bias were reliable when the correlation coefficient was >0.975. SDR produced reliable estimates of systematic bias for all cases studied, but the confidence intervals of systematic bias were unreliable when SDs of methods varied as a function of analyte concentration.

Conclusion: Only iteratively reweighted general Deming regression produced statistically unbiased estimates of systematic bias and reliable confidence intervals of bias for all cases.




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
S.-T. Lee, C. W. Weykamp, Y.-W. Lee, J.-W. Kim, and C.-S. Ki
Effects of 7 Hemoglobin Variants on the Measurement of Glycohemoglobin by 14 Analytical Methods
Clin. Chem., December 1, 2007; 53(12): 2202 - 2205.
[Abstract] [Full Text] [PDF]


Home page
Ann. N. Y. Acad. Sci.Home page
N. UMETANI, S. HIRAMATSU, and D. S.B HOON
Higher Amount of Free Circulating DNA in Serum than in Plasma Is Not Mainly Caused by Contaminated Extraneous DNA during Separation.
Ann. N.Y. Acad. Sci., September 1, 2006; 1075: 299 - 307.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
N. Ferre, J. Camps, J. Marsillach, B. Mackness, M. Mackness, B. Coll, M. Tous, and J. Joven
Comparison of Paraoxonase 1 Measurements in Serum and in Lithium-Heparin-Anticoagulated Plasma Samples
Clin. Chem., May 1, 2005; 51(5): 922 - 923.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
S. A. Santini, C. Carrozza, C. Vulpio, E. Capoluongo, G. Luciani, P. Lulli, B. Giardina, and C. Zuppi
Assessment of Parathyroid Function in Clinical Practice: Which Parathyroid Hormone Assay Is Better?
Clin. Chem., July 1, 2004; 50(7): 1247 - 1250.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
P. Suominen
Evaluation of an Enzyme Immunometric Assay to Measure Serum Adiponectin Concentrations
Clin. Chem., January 1, 2004; 50(1): 219 - 221.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
C. Gay-Bellile, D. Bengoufa, P. Houze, D. Le Carrer, M. Benlakehal, B. Bousquet, B. Gourmel, and T. Le Bricon
Automated Multicapillary Electrophoresis for Analysis of Human Serum Proteins
Clin. Chem., November 1, 2003; 49(11): 1909 - 1915.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
N. Khuseyinova, A. Imhof, G. Trischler, D. Rothenbacher, W. L. Hutchinson, M. B. Pepys, and W. Koenig
Determination of C-Reactive Protein: Comparison of Three High-Sensitivity Immunoassays
Clin. Chem., October 1, 2003; 49(10): 1691 - 1695.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
C. Bieglmayer, G. Prager, and B. Niederle
Kinetic Analyses of Parathyroid Hormone Clearance as Measured by Three Rapid Immunoassays during Parathyroidectomy
Clin. Chem., October 1, 2002; 48(10): 1731 - 1738.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
M. M. Flanders, R. Crist, S. Safapour, and G. M. Rodgers
Evaluation and Performance Characteristics of the STA-R Coagulation Analyzer
Clin. Chem., September 1, 2002; 48(9): 1622 - 1624.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
S. Rothkrantz-Kos, M. P.J. Schmitz, O. Bekers, P. P.C.A. Menheere, and M. P. van Dieijen-Visser
High-Sensitivity C-Reactive Protein Methods Examined
Clin. Chem., February 1, 2002; 48(2): 359 - 362.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American Association for Clinical Chemistry.