Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 46: 242-247, 2000;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (12)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ziebig, R.
Right arrow Articles by Sinha, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ziebig, R.
Right arrow Articles by Sinha, P.
Related Collections
Right arrow Hematology
(Clinical Chemistry. 2000;46:242-247.)
© 2000 American Association for Clinical Chemistry, Inc.


Articles

Leukocyte Counts in Cerebrospinal Fluid with the Automated Hematology Analyzer CellDyn 3500 and the Urine Flow Cytometer UF-100

Reinhard Ziebiga,1, Andreas Lun1 and Pranav Sinha1

1 Institut für Laboratoriumsmedizin und Pathobiochemie, Universitätsklinikum Charité, Campus Charité Mitte, Medizinische Fakultät der Humboldt Universität zu Berlin, Schumannstrasse 20-21, 10117 Berlin, Germany.
a Author for correspondence. Fax 49-030-2802-8422; e-mail reinhard.ziebig{at}charite.de

Background: The counting of leukocytes and erythrocytes in cerebrospinal fluid (CSF) is still performed microscopically, e.g., using a chamber in most laboratories. This requires sufficient practical experience, is time-consuming, and may constitute a problem in emergency diagnostics. Specific automated systems for CSF cell counting are not available at present.

Methods: We tested the hematology analyzer CellDyn 3500 (CD) and the urine flow cytometer UF-100 (UF), which are not designed for CSF analysis. We studied >104 samples with both analyzers, and the counts obtained were compared with the reference method (Fuchs-Rosenthal chamber).

Results: Good linearity in the medically relevant range of 15 x 106 to 1000 x 106 leukocytes/L and a high degree of within-run accuracy were seen for both analyzers. Cell counting on the UF was excellent, especially when low cell counts were encountered (CV, 4.9% compared with 28% observed for the CD). Method comparison showed that identical results could be detected for a majority of the count pairs. For a few samples, there was a discrepancy between the results from the analyzers and the counting chamber. In most cases, these were CSF samples containing a high proportion of lymphocytes. For these samples, the CD result led to a false-positive high leukocyte count, and on the UF these cells were not allocated to the leukocyte population, thus leading to false-negative counts.

Conclusions: Both analyzers should not be used for CSF cell counting in all cases at present. However, once the technical and software problems have been solved, routine use of the two analyzers for CSF analysis should be seriously contemplated.




The following articles in journals at HighWire Press have cited this article:


Home page
ChestHome page
B. D. Conner, Y. C. G. Lee, P. Branca, J. T. Rogers, R. M. Rodriguez, and R. W. Light
Variations in Pleural Fluid WBC Count and Differential Counts With Different Sample Containers and Different Methods
Chest, April 1, 2003; 123(4): 1181 - 1187.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. T. Van Acker, J. R. Delanghe, M. R. Langlois, Y. E. Taes, M. L. De Buyzere, and A. G. Verstraete
Automated Flow Cytometric Analysis of Cerebrospinal Fluid
Clin. Chem., March 1, 2001; 47(3): 556 - 560.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American Association for Clinical Chemistry.