Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 46: 273-278, 2000;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (24)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Revelen, R.
Right arrow Articles by Arvieux, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Revelen, R.
Right arrow Articles by Arvieux, J.
Related Collections
Right arrow Clinical Immunology
(Clinical Chemistry. 2000;46:273-278.)
© 2000 American Association for Clinical Chemistry, Inc.


Articles

False Positivity in a Cyto-ELISA for Anti-Endothelial Cell Antibodies Caused by Heterophile Antibodies to Bovine Serum Proteins

Ronan Revelen1, Anne Bordron1, Maryvonne Dueymes1, Pierre Youinou1 and Josiane Arvieuxa,1

1 Laboratory of Immunology, Institut de Synergie des Sciences et de la Santé, Brest University Medical School, F29609 Brest Cedex, France.
a Address correspondence to this author at: Laboratory of Immunology, Brest University Medical School Hospital, BP 824, F 29609, Brest Cedex, France. Fax 33-298-80-10-76; e-mail youinou{at}univ-brest.fr

Background: ELISAs with fixed endothelial cells or cell lines are widely used screening tests for anti-endothelial cell antibodies (AECAs), but spurious increases occur. We examined interferences by heteroantibodies and means to eliminate them.

Methods: AECAs were measured by ELISA on fixed layers of the human endothelial cell line, EA.hy 926, in a panel of 60 patient serum samples diluted in bovine serum albumin. Heteroantibodies against fetal calf serum (FCS) proteins were demonstrated and characterized in an ELISA—the interference assay—that used FCS-coated plates and Tween 20-containing buffer as blocking agent and sample diluent, as well as by immunoblotting.

Results: In 12 of 60 patient serum samples, spurious increases of AECA titers were produced by endogenous antibodies reacting with FCS proteins from culture medium that were coated onto the solid-phase at the time of cell plating. This mechanism of interference was supported experimentally by exposing extracellular matrix, varying cell density, and incubating wells with FCS alone. The heterophile antibodies were mainly IgG and IgA, and in inhibition experiments, they recognized serum proteins from goat, sheep, and horse. Washing cells free of FCS before plating, or adding FCS (100 mL/L) to the patient sample diluent eliminated spurious signals from all 30 tested sera, but the latter method had practical advantages.

Conclusions: Antibodies against animal serum proteins are a frequent cause of erroneous results in cyto-ELISAs. The interference can be eliminated by simple antibody absorption in FCS-containing dilution buffer.




The following articles in journals at HighWire Press have cited this article:


Home page
Ann Rheum DisHome page
C Belizna, A Duijvestijn, M Hamidou, and J W Cohen Tervaert
Antiendothelial cell antibodies in vasculitis and connective tissue disease
Ann Rheum Dis, December 1, 2006; 65(12): 1545 - 1550.
[Abstract] [Full Text] [PDF]


Home page
Infect. Immun.Home page
C. Dugue, R. Perraut, P. Youinou, and Y. Renaudineau
Effects of Anti-Endothelial Cell Antibodies in Leprosy and Malaria
Infect. Immun., January 1, 2004; 72(1): 301 - 309.
[Abstract] [Full Text] [PDF]


Home page
CVIHome page
C. Drouet, M.-F. Nissou, D. Ponard, J. Arvieux, C. Dumestre-Perard, P. Gaudin, B. Imbert, C. Massot, and F. Sarrot-Reynauld
Detection of Antiendothelial Cell Antibodies by an Enzyme-Linked Immunosorbent Assay Using Antigens from Cell Lysate: Minimal Interference with Antinuclear Antibodies and Rheumatoid Factors
Clin. Vaccine Immunol., September 1, 2003; 10(5): 934 - 939.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
L. J. Kricka
Interferences in Immunoassay--Still a Threat
Clin. Chem., August 1, 2000; 46(8): 1037 - 1038.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American Association for Clinical Chemistry.