Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 47: 1821-1828, 2001;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (34)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Krijt, J.
Right arrow Articles by Kozich, V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Krijt, J.
Right arrow Articles by Kozich, V.
Related Collections
Right arrow Endocrinology and Metabolism
(Clinical Chemistry. 2001;47:1821-1828.)
© 2001 American Association for Clinical Chemistry, Inc.


Articles

Measurement of Homocysteine and Other Aminothiols in Plasma: Advantages of Using Tris(2-carboxyethyl)phosphine as Reductant Compared with Tri-n-butylphosphine

Jakub Krijt1a, Martina Vacková1 and Viktor Kozich1

1 Institute of Inherited Metabolic Disorders, Charles University, 1st Faculty of Medicine, Ke Karlovu 2, Prague 2, Czech Republic.

aAuthor for correspondence. Fax 420-2-2491-9392 or 420-2-2492-1127; e-mail jkrijt{at}LF1.cuni.cz.

Background: Aminothiols have been implicated in the pathogenesis of arteriosclerosis, and reliable methods are needed to determine their concentrations in body fluids. We present a comparison of two analytical methods and focus on the reduction of low-molecular weight and protein-mixed disulfides of homocysteine, cysteine, cysteinyl-glycine, and glutathione.

Methods: The plasma total aminothiol profile was determined by HPLC with fluorescence detection after derivatization with ammonium 7-fluorobenzo-2-oxa-1,3-diazole-4-sulfonate. Disulfides and protein-bound aminothiols were reduced by either tri-n-butylphosphine (the TBP method) or tris(2-carboxyethyl)phosphine (the TCEP method); the effects of temperature, time of reduction, and concentration of reductants were evaluated.

Results: The intraassay imprecision (CV) was <3% for all aminothiols using both methods. The interassay CVs for total cysteine (tCys), total cysteinyl-glycine (tCys-Gly), and total homocysteine (tHcy) were <4% and <8% for the TCEP and TBP methods, respectively, whereas for total glutathione (tGSH) the interassay CV was >12% for both methods. Deming regression and Bland–Altman difference plots showed positive biases for total aminothiol concentrations determined by the TCEP method relative to the TBP method. The mean proportional biases were 65%, 27%, 6%, and 60% for tCys, tCys-Gly, tHcy, and tGSH, respectively. The calculated concentrations of total aminothiols by the TCEP method were less influenced by changes in temperature and concentration of reducing agent or by calibrator matrix.

Conclusions: The agreement between the TCEP and TBP methods was considerably lower for the determination of tCys, tCys-Gly, and tGSH than for tHcy. For total-aminothiol determination, the TCEP method yields better reproducibility and is more robust than the TBP method.




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
G. Cevasco, A. M. Mumot, C. Scapolla, and S. Thea
Ammonium 5-Bromo-7-fluorobenzo-2-oxa-1,3-diazole-4-sulphonate: A New Fluorogenic Reagent for the Determination of Aminothiols by HPLC
Clin. Chem., December 1, 2007; 53(12): 2221 - 2222.
[Full Text] [PDF]


Home page
J. Nutr.Home page
S. Toue, R. Kodama, M. Amao, Y. Kawamata, T. Kimura, and R. Sakai
Screening of Toxicity Biomarkers for Methionine Excess in Rats
J. Nutr., June 1, 2006; 136(6): 1716S - 1721S.
[Abstract] [Full Text] [PDF]


Home page
Drug Metab. Dispos.Home page
L. A. Peterson, M. E. Cummings, C. C. Vu, and B. A. Matter
GLUTATHIONE TRAPPING TO MEASURE MICROSOMAL OXIDATION OF FURAN TO CIS-2-BUTENE-1,4-DIAL
Drug Metab. Dispos., October 1, 2005; 33(10): 1453 - 1458.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the American Association for Clinical Chemistry.