Articles |
1
The Finsen Laboratory af.sn. 8621, Strandboulevarden 49, 2100 Copenhagen, Denmark.
2
Department of Biotechnology and
3
Paavo
Nurmi Center, University of Turku, 20520 Turku, Finland.
4
Department of Surgery, Turku University Central
Hospital, 20520 Turku, Finland.
5
Department of Clinical Chemistry, Turku University
Central Hospital, 20520 Turku, Finland.
6
Department of Laboratory Medicine, Division of Clinical
Chemistry, Lund University, University Hospital, 20502 Malmö,
Sweden.
a Author for correspondence. Fax 358-2-3338050; e-mail
kim.pettersson{at}utu.fi.
Background: The purpose of this study was to validate the use of whole-blood samples in the determination of circulating forms of prostate-specific antigen (PSA).
Methods: Blood samples of hospitalized prostate cancer and benign
prostatic hyperplasia patients were collected and processed to
generate whole-blood and serum samples. Three different rapid two-site
immunoassays were developed to measure the concentrations of total PSA
(PSA-T), free PSA (PSA-F), and PSA-
1-antichymotrypsin
complex (PSA-ACT) to detect in vitro changes in whole-blood samples
immediately after venipuncture. The possible influence of muscle
movement on the release of PSA from prostate gland was studied in
healthy men by measuring the rapid in vitro whole-blood kinetics of PSA
forms before and after 15 min of physical exercise on a stationary
bicycle.
Results: Rapid PSA-T, PSA-F, and PSA-ACT assays were designed using a 10-min sample incubation. No significant changes were detected in the concentrations of PSA-T, PSA-F, and PSA-ACT from the earliest time point of 1216 min compared with measurements performed up to 4 h after venipuncture. Physical exercise did not influence the concentrations of the circulating forms of PSA. Hematocrit-corrected whole-blood values of PSA-T and PSA-F forms were comparable to the respective serum values. Calculation of the percentage of PSA-F (PSA F/T ratio x 100) was similar irrespective of the sample format used, i.e., whole blood or serum.
Conclusions: We found that immunodetectable PSA forms are likely at steady state immediately after venipuncture, thus enabling the use of anticoagulated whole-blood samples in near-patient settings for point-of-care testing, whereas determinations of PSA (e.g., PSA-T, PSA-F, or PSA-ACT) performed within the time frame of the office visit would provide results equivalent to conventional analyses performed in serum.
The following articles in journals at HighWire Press have cited this article:
![]() |
Q.-P. Qin, M. Christiansen, and K. Pettersson Point-of-Care Time-resolved Immunofluorometric Assay for Human Pregnancy-associated Plasma Protein A: Use in First-Trimester Screening for Down Syndrome Clin. Chem., March 1, 2002; 48(3): 473 - 483. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. A. Stamey Preoperative Serum Prostate-specific Antigen (PSA) Below 10 {micro}g/L Predicts Neither the Presence of Prostate Cancer Nor the Rate of Postoperative PSA Failure Clin. Chem., April 1, 2001; 47(4): 631 - 634. [Abstract] [Full Text] [PDF] |
||||