Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 47: 1614-1621, 2001;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Web of Science (29)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Medintz, I. L.
Right arrow Articles by Mathies, R. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Medintz, I. L.
Right arrow Articles by Mathies, R. A.
Related Collections
Right arrow Molecular Diagnostics and Genetics
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 2001;47:1614-1621.)
© 2001 American Association for Clinical Chemistry, Inc.


Articles

Genotyping Energy-Transfer-Cassette-labeled Short-Tandem-Repeat Amplicons with Capillary Array Electrophoresis Microchannel Plates

Igor L. Medintz1, Lorenzo Berti1, Charles A. Emrich1, Jennifer Tom1, James R. Scherer1 and Richard A. Mathies1a

1 Department of Chemistry, University of California, Berkeley, CA 94720.

aAddress correspondence to this author at: 307 Lewis Hall, Department of Chemistry, University of California, Berkeley, CA 94720. Fax 510-642-3599; e-mail rich{at}zinc.cchem.berkeley.edu

Background: Genetic analysis of microsatellite DNA is a powerful tool used in linkage analysis, gene mapping, and clinical diagnosis. To address the expanding needs of studies of short tandem repeats (STRs), we demonstrated high-performance STR analysis on a high-throughput microchannel plate-based platform.

Methods: Energy-transfer-cassette-labeled STR amplicons were separated and typed on a microfabricated 96-channel radial capillary array electrophoresis (CAE) microchannel plate system. Four-color detection was accomplished with a laser-excited confocal fluorescence rotary scanner.

Results: Multiplex STR analysis with single base-pair resolution was demonstrated on denaturing polyacrylamide gel media. The high-throughput multiplex capabilities of this genetic analysis platform were demonstrated by the simultaneous separation of STR amplicons representing 122 samples in ninety-six 5.5-cm-long channels in <8 min. Sizing values obtained for these amplicons on the CAE microchannel plate were comparable to those measured on a conventional commercial CAE instrument and exhibit <1% sizing variance.

Conclusions: Energy-transfer-cassette labeling and microfabricated CAE microchannel plates allow high-performance multiplex STR analyses.