Clinical Chemistry 48: 161-166, 2002;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Siek, G.
Right arrow Articles by Musto, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Siek, G.
Right arrow Articles by Musto, J.
Related Collections
Right arrow Molecular Diagnostics and Genetics
Right arrow General Clinical Chemistry
Right arrow Hematology
Right arrow Endocrinology and Metabolism
(Clinical Chemistry. 2002;48:161-166.)
© 2002 American Association for Clinical Chemistry, Inc.

Direct Serum Total Iron-binding Capacity Assay Suitable for Automated Analyzers

Gordon Siek1a, Joseph Lawlor1, Donna Pelczar1, Meena Sane1 and Joseph Musto1,2

1 Reference Diagnostics, Inc., 19 Crosby Dr., Suite 30, Bedford, MA 01730.

2 Diagnostic Laboratory Medicine, Inc., 14 Crosby Dr., Bedford, MA 01730.

aAuthor for correspondence. Fax 781-276-9002; e-mail gsiek{at}ref-dx.com.

Background: Present methods for measuring serum total iron-binding capacity (TIBC) involve manipulation of samples or performance of two assays on each sample. We developed a direct automated assay (DTIBC) for TIBC.

Methods: We added to serum a saturating amount of iron bound to an excess of chelating dye at a low pH, recorded a blank reading that represented the sum of the saturating amount of iron plus the serum iron, and then added a strong neutral pH buffer. The decrease in absorbance (as transferrin extracts iron from the iron-dye complex) is directly proportional to the TIBC. TIBC values for 125 patients were determined by DTIBC, alumina column TIBC (AC), magnetic particle TIBC (MTIBC), and the UIBC method (UIBC) on Roche COBAS FARA and Mira chemistry analyzers. In a separate study, TIBC values for 128 patients were determined on an Olympus AU400 by the DTIBC and the MTIBC methods.

Results: Methods comparisons on the COBAS analyzers yielded the following results: DTIBC = 1.05(MTIBC) - 1.0 µmol/L (r = 0.987; Sy|x = 2.6 µmol/L); DTIBC = 1.07(AC) - 1.0 µmol/L (r = 0.982; Sy|x = 3.0 µmol/L); and DTIBC = 1.14(UIBC) + 3.4 µmol/L (r = 0.982; Sy|x = 3.0 µmol/L). A similar correlation study using the Olympus AU400 yielded DTIBC = 1.00(MTIBC) - 0.1 µmol/L (r = 0.983; Sy|x = 2.7 µmol/L). The assay was linear from 12.5 to 125 µmol/L (70–700 µg/dL) TIBC on the COBAS FARA. Within- and between-run imprecision (CV) was <=4.8% at two concentrations. Plasma samples were unsuitable for the method. No interference was seen with common interferants other than ascorbate, deferoxamine, and ferrous sulfate, and only at concentrations well above normal.

Conclusion: The new DTIBC assay is suitable for routine use in clinical laboratories and may improve the quality of iron metabolism studies.




The following articles in journals at HighWire Press have cited this article:


Home page
Cancer Res.Home page
C. Hartford, E. Vasquez, M. Schwab, M. J. Edick, J. E. Rehg, G. Grosveld, C.-H. Pui, W. E. Evans, and M. V. Relling
Differential Effects of Targeted Disruption of Thiopurine Methyltransferase on Mercaptopurine and Thioguanine Pharmacodynamics
Cancer Res., May 15, 2007; 67(10): 4965 - 4972.
[Abstract] [Full Text] [PDF]


Home page
J. Nutr.Home page
C. Chaudhury, J. Kim, S. Mehnaz, M. A. Wani, T. M. Oberyszyn, C. L. Bronson, S. Mohanty, W. L. Hayton, J. M. Robinson, and C. L. Anderson
Accelerated Transferrin Degradation in HFE-Deficient Mice Is Associated with Increased Transferrin Saturation
J. Nutr., December 1, 2006; 136(12): 2993 - 2998.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
H. Yamanishi, S. Iyama, Y. Yamaguchi, Y. Kanakura, and Y. Iwatani
Total Iron-binding Capacity Calculated from Serum Transferrin Concentration or Serum Iron Concentration and Unsaturated Iron-binding Capacity
Clin. Chem., January 1, 2003; 49(1): 175 - 178.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
H. Yamanishi, S. Iyama, Y. Yamaguchi, Y. Kanakura, and Y. Iwatani
Modification of Fully Automated Total Iron-binding Capacity (TIBC) Assay in Serum and Comparison with Dimension TIBC Method
Clin. Chem., September 1, 2002; 48(9): 1565 - 1570.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the American Association for Clinical Chemistry.