Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 48: 2202-2207, 2002;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Salomo, M.
Right arrow Articles by Nielsen, L. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Salomo, M.
Right arrow Articles by Nielsen, L. B.
Related Collections
Right arrow Clinical Immunology
Right arrow Proteomics and Protein Markers
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 2002;48:2202-2207.)
© 2002 American Association for Clinical Chemistry, Inc.

Simple Method for Quantification of Bence Jones Proteins

Morten Salomo1, Peter Gimsing1 and Lars B. Nielsen2a

Departments of
1 Hematology and
2 Clinical Biochemistry, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, DK-2100 Copenhagen, Denmark.

aAddress correspondence to this author at: Department of Clinical Biochemistry, KB 3011 Rigshospitalet, University of Copenhagen, Blegdamsvej 9, DK-2100 Copenhagen, Denmark. Fax 45-45352524; e-mail larsbo{at}rh.dk.

Background: Quantification of free monoclonal light chains in urine [Bence Jones proteins (BJPs)] is used to diagnose multiple myeloma and to evaluate response to treatment. We have developed and evaluated an optimized approach for quantification of BJPs.

Methods: High-resolution gel electrophoresis of unconcentrated urine and albumin calibrators was carried out on Sebia’s Hydrasys instrument with Hydragel HR agarose gels. After staining with acid violet, the gels were scanned densitometrically. The staining intensities of BJP bands relative to the staining intensities of albumin solutions were used to determine the BJP concentrations. Results for patient samples were compared with conventional agarose gel electrophoresis on concentrated samples.

Results: The relationships between staining intensity and the protein concentrations of albumin and BJPs were linear up to protein concentrations of ~2000 mg/L. The detection limit was ~20 mg/L. The interassay imprecision (CV) was ~8% (n = 23, duplicate analysis), and the results (y) showed a close positive relationship to the comparison method: slope = 0.82 (confidence interval, 0.75-0.88); y-intercept = 34 (-14 to 81) mg/L; n = 29; r2 = 0.96.

Conclusions: Agarose gel electrophoresis of unconcentrated urine samples together with a series of albumin calibrators followed by acid violet staining and densitometric scanning is sufficiently reproducible and sensitive to quantify clinically relevant BJPs.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the American Association for Clinical Chemistry.