Oak Ridge Conference |
1 Protein Science Department, Genomics Institute of the Novartis Research Foundation, San Diego, CA.
2 Department of Chemistry and the Skaggs Institute for Chemical Biology, The Scripps Research Institute, La Jolla, CA.
aAddress correspondence to this author at: Protein Science Department, Genomics Institute of the Novartis Research Foundation, 10675 John Jay Hopkins Dr., San Diego, CA 92121-1125. Fax 858-812-1746; e-mail geierstanger{at}gnf.org.
Abstract
Background: Conceptionally, antibody microarrays are simply multiplexed sandwich immunoassays in a miniaturized format. However, from the amounts of capture antibodies used, it is not apparent whether such assays are ambient analyte (Ekins. Clin Chem 1998;44:201530) or mass-sensing devices (Silzel et al. Clin Chem 1998;44:203643). We evaluated multiplexed microarray sandwich assays for 24 mouse serum proteins in these terms within the boundaries of our experimental setup and based on theoretical considerations of the law of mass action.
Methods: Capture antibodies for 24 mouse serum proteins were printed on planar microarray substrates. After incubation with mixtures of purified antigens for 1 or 18 h, mixtures of biotinylated detection antibodies were used. High assay sensitivity was achieved by use of resonance-light-scattering particles for signal generation. Titration curves were generated for assay volumes of 20, 40, and 80 µL, and detection limits were calculated and compared. The assays were modeled theoretically based on the amounts of capture antibodies and the assay volumes used.
Results: As predicted, experimental variations of the assay volume by up to fourfold did not appreciably affect detection. Even for the most sensitive assay, <2% of the analyte molecules present in the sample were captured and generated signal at the detection limit. However, increasing the sample incubation time from 1 to 18 h on average lowered the detection limit threefold.
Conclusions: In our experimental setup, all 24 sandwich microarray assays fulfill the criteria of the "ambient analyte" regime because depletion of analyte molecules from the assay volume is insignificant.
The following articles in journals at HighWire Press have cited this article:
![]() |
A. Claudon, P. Vergnaud, C. Valverde, A. Mayr, U. Klause, and P. Garnero New Automated Multiplex Assay for Bone Turnover Markers in Osteoporosis Clin. Chem., September 1, 2008; 54(9): 1554 - 1563. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Kverka, J. Burianova, R. Lodinova-Zadnikova, I. Kocourkova, J. Cinova, L. Tuckova, and H. Tlaskalova-Hogenova Cytokine Profiling in Human Colostrum and Milk by Protein Array Clin. Chem., May 1, 2007; 53(5): 955 - 962. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Kusnezow, Y. V. Syagailo, S. Ruffer, N. Baudenstiel, C. Gauer, J. D. Hoheisel, D. Wild, and I. Goychuk Optimal Design of Microarray Immunoassays to Compensate for Kinetic Limitations: Theory and Experiment Mol. Cell. Proteomics, September 1, 2006; 5(9): 1681 - 1696. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Sanchez-Carbayo Antibody Arrays: Technical Considerations and Clinical Applications in Cancer Clin. Chem., September 1, 2006; 52(9): 1651 - 1659. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. B. Haab Antibody Arrays in Cancer Research Mol. Cell. Proteomics, April 1, 2005; 4(4): 377 - 383. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Y. H. Lin, M. Sabri, J. Alirezaie, D. Li, and P. M. Sherman Development of a Nanoparticle-Labeled Microfluidic Immunoassay for Detection of Pathogenic Microorganisms Clin. Vaccine Immunol., March 1, 2005; 12(3): 418 - 425. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |