Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 50: 2338-2344, 2004. First published October 7, 2004; 10.1373/clinchem.2004.039156
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2004.039156v1
50/12/2338    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (15)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rawlins, M. L.
Right arrow Articles by Roberts, W. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rawlins, M. L.
Right arrow Articles by Roberts, W. L.
Related Collections
Right arrow Endocrinology and Metabolism
(Clinical Chemistry. 2004;50:2338-2344.)
© 2004 American Association for Clinical Chemistry, Inc.


Endocrinology and Metabolism

Performance Characteristics of Six Third-Generation Assays for Thyroid-Stimulating Hormone

Mindy L. Rawlins1 and William L. Roberts2,a

1 ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT.
2 Department of Pathology, University of Utah Health Sciences Center, Salt Lake City, UT.

aAddress correspondence to this author at: ARUP Laboratories, 500 Chipeta Way, Salt Lake City, UT 84108. Fax 801-584-5207; e-mail william.roberts{at}aruplab.com.

Background: Thyroid-stimulating hormone (TSH) is used to detect primary hypo- and hyperthyroidism. Current guidelines for TSH assays recommend a functional sensitivity of ≤0.02 mIU/L. The protocol for determining the functional sensitivity of TSH assays specifies analyses of serum samples with two reagent lots over a 6- to 8-week period.

Methods: We determined the functional sensitivities of the Access 2, ADVIA Centaur, ARCHITECT i2000, E170, IMMULITE 2000, and Vitros ECi automated methods, using seven serum pools and two reagent lots for each method.

Results: The observed functional sensitivities were as follows: Access 2, <0.020 mIU/L; ADVIA Centaur, 0.039 mIU/L; ARCHITECT i2000, <0.005 mIU/L; Elecsys E170, 0.011 mIU/L; IMMULITE 2000, 0.014 mIU/L; Vitros ECi, 0.004 mIU/L. However, there were large differences between some method means for the seven serum pools. For the pool with the lowest TSH concentration, mean results were as follows: Access 2, 0.0203 mIU/L; ADVIA Centaur, 0.0085 mIU/L; ARCHITECT i2000, 0.0049 mIU/L; E170, 0.0098 mIU/L; IMMULITE 2000, 0.0077 mIU/L; Vitros ECi, 0.0014 mIU/L. Method-comparison studies using samples with TSH concentrations >0.2 mIU/L also showed method differences. The ARCHITECT i2000 method was the most precise at low TSH concentrations.

Conclusions: TSH methods do not provide comparable results for serum pools with TSH concentrations <0.2 mIU/L or for patient results across the analytic measurement range. Further investigation into the cause of these differences and additional harmonization efforts are required.




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
B. Goichot, R. Sapin, and J. L. Schlienger
Subclinical Hyperthyroidism: Considerations in Defining the Lower Limit of the Thyrotropin Reference Interval
Clin. Chem., March 1, 2009; 55(3): 420 - 424.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
C. A. Spencer, J. G. Hollowell, M. Kazarosyan, and L. E. Braverman
National Health and Nutrition Examination Survey III Thyroid-Stimulating Hormone (TSH)-Thyroperoxidase Antibody Relationships Demonstrate That TSH Upper Reference Limits May Be Skewed by Occult Thyroid Dysfunction
J. Clin. Endocrinol. Metab., November 1, 2007; 92(11): 4236 - 4240.
[Abstract] [Full Text] [PDF]


Home page
Eur J EndocrinolHome page
G Brabant, P Beck-Peccoz, B Jarzab, P Laurberg, J Orgiazzi, I Szabolcs, A P Weetman, and W M Wiersinga
Is there a need to redefine the upper normal limit of TSH?
Eur. J. Endocrinol., May 1, 2006; 154(5): 633 - 637.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
K. Zophel, G. Wunderlich, and J. Kotzerke
Should We Really Determine a Reference Population for the Definition of Thyroid-Stimulating Hormone Reference Interval?
Clin. Chem., February 1, 2006; 52(2): 329 - 330.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
S. Donadio, A. Pascual, J. H.H. Thijssen, and C. Ronin
Feasibility Study of New Calibrators for Thyroid-Stimulating Hormone (TSH) Immunoprocedures Based on Remodeling of Recombinant TSH to Mimic Glycoforms Circulating in Patients with Thyroid Disorders
Clin. Chem., February 1, 2006; 52(2): 286 - 297.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
D. Waskiewicz, A. Burkhardt, and K. Emancipator
Performance Characteristics of 6 Third-Generation Assays for Thyroid-Stimulating Hormone
Clin. Chem., October 1, 2005; 51(10): 1904 - 1905.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
W. L. Roberts
Performance Characteristics of 6 Third-Generation Assays for Thyroid-Stimulating Hormone: Dr. Roberts responds
Clin. Chem., October 1, 2005; 51(10): 1905 - 1905.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Association for Clinical Chemistry.