Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 50: 819-825, 2004. First published March 9, 2004; 10.1373/clinchem.2003.027961
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2003.027961v1
50/5/819    most recent
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (21)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Burggraf, S.
Right arrow Articles by Olgemöller, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Burggraf, S.
Right arrow Articles by Olgemöller, B.
Related Collections
Right arrow Molecular Diagnostics and Genetics
(Clinical Chemistry. 2004;50:819-825.)
© 2004 American Association for Clinical Chemistry, Inc.


Molecular Diagnostics and Genetics

Simple Technique for Internal Control of Real-Time Amplification Assays

Siegfried Burggraf1,a and Bernhard Olgemöller1

1 Labor Becker, Olgemöller und Kollegen, Führichstrasse 70, 81671 München, Germany.

aAuthor for correspondence. Fax 49-89-450917-300; e-mail sburggraf{at}labor-bo.de.

Background: In real-time PCR assays, the most accurate way to identify false-negative results, e.g., those caused by PCR inhibitors, is to add to samples an internal control that will be coamplified with the target (e.g., pathogen) DNA. Current internal control procedures, however, which usually involve the introduction of a DNA fragment, are complex, time-consuming, and expensive.

Methods: Single-stranded oligonucleotides, which contain little more than primer and probe binding sites, were used as internal controls in real-time PCR assays. Mismatches were included in the probe-binding region of the internal control oligonucleotide (ICO) to prevent probe–control hybridization during the fluorescence acquisition step of the PCR. Amplified ICOs were detected by melting point analysis. ICOs could be added directly to the sample material before DNA extraction.

Results: To demonstrate the feasibility of the new approach, we designed ICOs for the LightCycler hybridization probe assays for Mycobacterium tuberculosis complex, hepatitis B virus, herpes simplex virus, and varicella zoster virus. In each case, the controls did not interfere with detection of the pathogen, but were clearly detectable during a subsequent melting point analysis.

Conclusions: A single-stranded oligonucleotide that mimics the target region of the pathogen but is clearly distinguishable from the target during melting point analysis can serve as a simple, cost-effective internal control for real-time amplification assays. Such control oligonucleotides are easy to design and inexpensive. A costly second probe system is not necessary. Moreover, the internally controlled assay uses only one fluorescence detection channel of the instrument, leaving the second channel free for multiplex applications.




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
M. Stormer, K. Kleesiek, and J. Dreier
High-Volume Extraction of Nucleic Acids by Magnetic Bead Technology for Ultrasensitive Detection of Bacteria in Blood Components
Clin. Chem., January 1, 2007; 53(1): 104 - 110.
[Abstract] [Full Text] [PDF]


Home page
Clin. Microbiol. Rev.Home page
M. J. Espy, J. R. Uhl, L. M. Sloan, S. P. Buckwalter, M. F. Jones, E. A. Vetter, J. D. C. Yao, N. L. Wengenack, J. E. Rosenblatt, F. R. Cockerill III, et al.
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Clin. Microbiol. Rev., January 1, 2006; 19(1): 165 - 256.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
S. Burggraf and B. Olgemoller
Straightforward Procedure for Internal Control of Real-Time Reverse Transcription Amplification Assays
Clin. Chem., August 1, 2005; 51(8): 1508 - 1510.
[Full Text] [PDF]


Home page
J. Clin. Microbiol.Home page
S. Burggraf, U. Reischl, N. Malik, M. Bollwein, L. Naumann, and B. Olgemoller
Comparison of an Internally Controlled, Large-Volume LightCycler Assay for Detection of Mycobacterium tuberculosis in Clinical Samples with the COBAS AMPLICOR Assay
J. Clin. Microbiol., April 1, 2005; 43(4): 1564 - 1569.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
F. S. Nolte
Novel Internal Controls For Real-Time PCR Assays
Clin. Chem., May 1, 2004; 50(5): 801 - 802.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Association for Clinical Chemistry.