Clinical Chemistry Siemens Point of Care - Urinalysis
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 51: 65-74, 2005. First published November 18, 2004; 10.1373/clinchem.2004.037283
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow All Versions of this Article:
clinchem.2004.037283v1
51/1/65    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (29)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Malyarenko, D. I.
Right arrow Articles by Manos, D. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Malyarenko, D. I.
Right arrow Articles by Manos, D. M.
Related Collections
Right arrow Laboratory Management
Right arrow General Clinical Chemistry
Right arrow Proteomics and Protein Markers
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 2005;51:65-74.)
© 2005 American Association for Clinical Chemistry, Inc.


Proteomics and Protein Markers

Enhancement of Sensitivity and Resolution of Surface-Enhanced Laser Desorption/Ionization Time-of-Flight Mass Spectrometric Records for Serum Peptides Using Time-Series Analysis Techniques

Dariya I. Malyarenko1,5,a, William E. Cooke2, Bao-Ling Adam3,1, Gunjan Malik3, Haijian Chen2,5, Eugene R. Tracy2, Michael W. Trosset4, Maciek Sasinowski5, O. John Semmes3 and Dennis M. Manos1,2

Departments of1 Applied Science, 2 Physics, and 4 Mathematics, the College of William and Mary, Williamsburg, VA.
3 Department of Microbiology and Molecular Cell Biology, Eastern Virginia Medical School, Norfolk, VA.
5 INCOGEN, Inc., Williamsburg, VA.

aAddress correspondence to this author at: Department of Physics, the College of William and Mary, Williamsburg, VA 23187-8795. Fax 757-221-3540; e-mail dasha{at}compsci.wm.edu.

Background: Measurement of peptide/protein concentrations in biological samples for biomarker discovery commonly uses high-sensitivity mass spectrometers with a surface-processing procedure to concentrate the important peptides. These time-of-flight (TOF) instruments typically have low mass resolution and considerable electronic noise associated with their detectors. The net result is unnecessary overlapping of peaks, apparent mass jitter, and difficulty in distinguishing mass peaks from background noise. Many of these effects can be reduced by processing the signal using standard time-series background subtraction, calibration, and filtering techniques.

Methods: Surface-enhanced laser desorption/ionization (SELDI) spectra were acquired on a PBS II instrument from blank, hydrophobic, and IMAC-Cu ProteinChip® arrays (Ciphergen Biosystems, Inc.) incubated with calibration peptide mixtures or pooled serum. TOF data were recorded after single and multiple laser shots at different positions. Correlative analysis was used for time-series calibration. Target filters were used to suppress noise and enhance resolution after baseline removal and noise rescaling.

Results: The developed algorithms compensated for the electronic noise attributable to detector overload, removed the baseline caused by charge accumulation, detected and corrected mass peak jitter, enhanced signal amplitude at higher masses, and improved the resolution by using a deconvolution filter.

Conclusions: These time-series techniques, when applied to SELDI-TOF data before any peak identification procedure, can improve the data to make the peak identification process simpler and more robust. These improvements may be applicable to most TOF instrumentation that uses analog (rather than counting) detectors.




The following articles in journals at HighWire Press have cited this article:


Home page
BioinformaticsHome page
Y. Wang, X. Zhou, H. Wang, K. Li, L. Yao, and S. T.C. Wong
Reversible jump MCMC approach for peak identification for stroke SELDI mass spectrometry using mixture model
Bioinformatics, July 1, 2008; 24(13): i407 - i413.
[Abstract] [Full Text] [PDF]


Home page
BioinformaticsHome page
M. Skold, T. Ryden, V. Samuelsson, C. Bratt, L. Ekblad, H. Olsson, and B. Baldetorp
Regression analysis and modelling of data acquisition for SELDI-TOF mass spectrometry
Bioinformatics, June 1, 2007; 23(11): 1401 - 1409.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. Albrethsen
Reproducibility in Protein Profiling by MALDI-TOF Mass Spectrometry
Clin. Chem., May 1, 2007; 53(5): 852 - 858.
[Abstract] [Full Text] [PDF]


Home page
BioinformaticsHome page
H. W. Ressom, R. S. Varghese, S. K. Drake, G. L. Hortin, M. Abdel-Hamid, C. A. Loffredo, and R. Goldman
Peak selection from MALDI-TOF mass spectra using ant colony optimization
Bioinformatics, March 1, 2007; 23(5): 619 - 626.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
K. R. Coombes
Analysis of Mass Spectrometry Profiles of the Serum Proteome - Reply
Clin. Chem., July 1, 2005; 51(7): 1309 - 1309.
[Full Text] [PDF]


Home page
BioinformaticsHome page
J. S. Morris, K. R. Coombes, J. Koomen, K. A. Baggerly, and R. Kobayashi
Feature extraction and quantification for mass spectrometry in biomedical applications using the mean spectrum
Bioinformatics, May 1, 2005; 21(9): 1764 - 1775.
[Abstract] [Full Text] [PDF]


Home page
JNCI J Natl Cancer InstHome page
L. A. Liotta, M. Lowenthal, A. Mehta, T. P. Conrads, T. D. Veenstra, D. A. Fishman, and E. F. Petricoin III
Importance of Communication Between Producers and Consumers of Publicly Available Experimental Data
J Natl Cancer Inst, February 16, 2005; 97(4): 310 - 314.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
K. R. Coombes
Analysis of Mass Spectrometry Profiles of the Serum Proteome
Clin. Chem., January 1, 2005; 51(1): 1 - 2.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the American Association for Clinical Chemistry.