Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 51: 1132-1136, 2005; 10.1373/clinchem.2004.039909
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Data Supplements
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (3)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lai, K. K.-Y.
Right arrow Articles by Jerome, K. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lai, K. K.-Y.
Right arrow Articles by Jerome, K. R.
Related Collections
Right arrow Molecular Diagnostics and Genetics
Right arrow Laboratory Management
(Clinical Chemistry. 2005;51:1132-1136.)
© 2005 American Association for Clinical Chemistry, Inc.


Molecular Diagnostics and Genetics

Calibration Curves for Real-Time PCR

K. Kay-Yin Lai1, Linda Cook1, Elizabeth M. Krantz1, Lawrence Corey1,2,3 and Keith R. Jerome1,3,a

Departments of1 Laboratory Medicine and2 Medicine, University of Washington Medical Center, Seattle, WA.
3 Program in Infectious Diseases, Fred Hutchinson Cancer Research Center, Seattle, WA.

aAddress correspondence to this author at: Fred Hutchinson Cancer Research Center, 1100 Fairview Ave. N, D3-100, Seattle, WA 98109. Fax 206-667-4411; e-mail kjerome{at}fhcrc.org.

Background: Despite the increasing use of real-time PCR in the diagnosis and management of viral infections, there are no published studies adequately addressing the optimum number of calibrators, the number of replicates of each calibrator, and the frequency with which calibration needs to be repeated. This study was designed to address these issues.

Methods: Cycle threshold data (ABI 7700) was collected from >50 consecutive real-time PCR runs for hepatitis B and Epstein–Barr viruses. Our routine calibration curve made from serial 10-fold dilutions run in duplicate was compared with alternative options, including duplicate 100-fold dilutions, inclusion of a low-copy calibrator, and omission of the duplicate determination. Control data were used to examine the use of an average calibration curve made from multiple runs.

Results: Use of duplicate serial 10-fold dilutions led to the least imprecision, duplicate 100-fold dilutions had slightly higher imprecision, and calibration curves obtained with singlet measurements showed the greatest imprecision. For patient data, the duplicate 100-fold dilution calibration curve produced results that best matched those from the routine calibration curve. Use of singlet dilutions or inclusion of a low-copy calibrator produced poorer agreement. Variability in controls was lower with a daily calibration curve than with an average calibration curve.

Conclusions: Duplicate 100-fold dilution calibration curves produced equivalent results and the same imprecision as curves with more calibrators, and thus are a valid alternative. Laboratories should carefully evaluate the variability resulting from the use of average calibration curves before adopting this approach.




The following articles in journals at HighWire Press have cited this article:


Home page
Appl. Environ. Microbiol.Home page
R. D. Stedtfeld, S. W. Baushke, D. M. Tourlousse, S. M. Miller, T. M. Stedtfeld, E. Gulari, J. M. Tiedje, and S. A. Hashsham
Development and Experimental Validation of a Predictive Threshold Cycle Equation for Quantification of Virulence and Marker Genes by High-Throughput Nanoliter-Volume PCR on the OpenArray Platform
Appl. Envir. Microbiol., June 15, 2008; 74(12): 3831 - 3838.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
L. A. Baxter-Lowe and M. P. Busch
Tracking microchimeric DNA in plasma to diagnose and manage organ transplant rejection.
Clin. Chem., April 1, 2006; 52(4): 559 - 561.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the American Association for Clinical Chemistry.