Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 53: 1962-1965, 2007. First published August 30, 2007; 10.1373/clinchem.2007.089854
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow 089854.Supplemental Data
Right arrow All Versions of this Article:
clinchem.2007.089854v1
53/11/1962    most recent
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chen, G.
Right arrow Articles by Nazarenko, I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chen, G.
Right arrow Articles by Nazarenko, I.
Related Collections
Right arrow Molecular Diagnostics and Genetics
(Clinical Chemistry. 2007;53:1962-1965.)
© 2007 American Association for Clinical Chemistry, Inc.


Technical Briefs

Effect of Sample Aliquot Size on the Limit of Detection and Reproducibility of Clinical Assays

Guorong Chen, Lori Kobayashi and Irina Nazarenkoa

Digene Corporation, Gaithersburg, MD;

aaddress correspondence to this author at: Digene Corporation, Research and Development, 1201 Clopper Rd., Gaithersburg, MD 20878; fax 301-944-7301, e-mail irina.nazarenko{at}digene.com


Abstract

Background: Nucleic acid amplification technologies significantly improved the limit of detection (LOD) for diagnostic assays. The ability of these assays to amplify fewer than 10 target copies of DNA or RNA imposes new requirements on the preparation of clinical samples. We report a statistical method to determine how large of an aliquot is necessary to reproducibly provide a detectable number of cells.

Methods: We determined the success probability (p) based on aliquot size and sample volume. The binomial distribution, based on p and the concentration of cells in sample, was used to calculate the probability of getting no target objects in an aliquot and to determine the minimum number of objects per aliquot necessary to generate a reproducible clinical assay.

Results: The described method was applied to find a minimum aliquot volume required for a set LOD, false-negative rate (FNR), and %CV. For example, to keep FNR <0.01% for 0.5%, 1% and 2% aliquots (minimum 2000, 1000, and 500 cells per sample) are required. Comparison between experimental and predicted FNR demonstrated good correlation for the small volume aliquots and/or low concentration of target. When 4 µL of 200 copies/mL of plasmid is amplified, predicted and experimental FNRs are 47.2% and 44.9%.

Conclusion: This probability model is a useful tool to predict the impact of aliquot volume on the LOD and reproducibility of clinical assays. Even for samples for which pathogens are homogeneously distributed, it is theoretically impossible to collect a single pathogen consistently if the concentration of pathogen is below a certain limit.