Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 53: 1122-1128, 2007. First published May 3, 2007; 10.1373/clinchem.2006.083493
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2006.083493v1
53/6/1122    most recent
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mahoney, J.
Right arrow Articles by Ellison, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mahoney, J.
Right arrow Articles by Ellison, J.
Related Collections
Right arrow General Clinical Chemistry
(Clinical Chemistry. 2007;53:1122-1128.)
© 2007 American Association for Clinical Chemistry, Inc.


General Clinical Chemistry

Assessing the Quality of Glucose Monitor Studies: A Critical Evaluation of Published Reports

John Mahoney1,a and John Ellison2

Departments of1 Global Product Support and 2 Clinical Research, LifeScan, Inc.

aAddress correspondence to this author at: LifeScan, Inc., 1000 Gibraltar Dr., M/S 3I, Milpitas, CA 95035-6312. Fax 1-408-941-9892; e-mail address jmahoney{at}lfsus.jnj.com.

Background: In recent years, a large number of studies have been published on the performance of glucose monitors. The quality of these reports is not known.

Methods: We searched the PubMed database for performance evaluations of handheld glucose monitors published from August 2002 to November 2006. Relevant articles were compared to 20 recommendations from the Standards for Reporting Diagnostic Accuracy (STARD) and 18 recommendations from the Clinical and Laboratory Standards Institute (CLSI).

Results: A total of 52 reports met our inclusion criteria and were reviewed. None (0%) of the reports conformed to all 38 STARD and CLSI recommendations. The range of compliance to these recommendations varied widely (median 53%; range 21%–84%). Only 1 study of the 52 reported following a CLSI recommendation for checking reference test results. Fewer than half (42%) of the reports contained STARD-recommended statements regarding how and when comparative measurements were performed.

Conclusions: None of the glucose monitor reports from our review conformed to all STARD and CLSI recommendations. Our finding that the average rate of compliance to recommendations was low suggests that many of the researchers did not follow published recommendations for study design, methodology, and reporting and that study quality and conclusions may have been affected. Future studies evaluating the performance of glucose monitoring systems should be carefully designed and follow published recommendations for methodological and reporting quality.




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
N. Rifai, D. G. Altman, and P. M. Bossuyt
Reporting Bias in Diagnostic and Prognostic Studies: Time for Action
Clin. Chem., July 1, 2008; 54(7): 1101 - 1103.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2007 by the American Association for Clinical Chemistry.