Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 54: 366-370, 2008. First published December 21, 2007; 10.1373/clinchem.2007.094417
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2007.094417v1
54/2/366    most recent
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Negi, A. S.
Right arrow Articles by Sood, A. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Negi, A. S.
Right arrow Articles by Sood, A. K.
Related Collections
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 2008;54:366-370.)
© 2008 American Association for Clinical Chemistry, Inc.


Automation and Analytical Techniques

Electric Field–Enhanced Sensitivity of Grafted Ligands and Receptors

Ajay Singh Negi and Ajay Kumar Sooda

Department of Physics, Indian Institute of Science, Bangalore, India.

aAddress correspondence to this author at: Department of Physics, Indian Institute of Science, Bangalore, 560012, India. Fax 91-80-23602602; e-mail asood{at}physics.iisc.ernet.in.

Background: Particle-based agglutination tests consisting of receptors grafted to colloidal microparticles are useful for detecting small quantities of corresponding ligands of interest in fluid test samples, but detection limits of such tests are limited to a certain concentration and it is most desirable to lower the detection limits and to enhance the rate of recognition of ligands.

Methods: A mixture of receptor-coated colloidal microparticles and corresponding ligand was sandwiched between 2 indium tin oxide–coated glass plates. Electrohydrodynamic drag from an alternating-current electric field applied perpendicular to the plates increased the local concentration of the colloidal particles, improving the chances of ligand-receptor interaction and leading to the aggregation of the colloidal particles.

Results: With this technique the sensitivity of the ligand-receptor recognition was increased by a factor as large as 50.

Conclusions: This method can improve the sensitivity of particle-based agglutination tests used in immunoassays and many other applications such as immunoprecipitation and chemical sniffing.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS