Clinical Chemistry Siemens Point of Care - Urinalysis
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 55: 139-149, 2009. First published November 6, 2008; 10.1373/clinchem.2008.115378
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow HTML Page - index.htslp
Right arrow All Versions of this Article:
clinchem.2008.115378v1
55/1/139    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Meyer, K.
Right arrow Articles by Ueland, P. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Meyer, K.
Right arrow Articles by Ueland, P. M.
(Clinical Chemistry. 2009;55:139-149.)
© 2009 American Association for Clinical Chemistry, Inc.


Molecular Diagnostics and Genetics

MALDI-TOF MS Genotyping of Polymorphisms Related to 1-Carbon Metabolism Using Common and Mass-Modified Terminators

Klaus Meyer1,2,a, Åse Fredriksen2 and Per Magne Ueland2,3

1 Bevital A/S, Armauer Hansens Hus, Bergen, Norway; 2 Section for Pharmacology, Institute of Medicine, Armauer Hansens Hus, University of Bergen, Bergen, Norway; 3 Laboratory of Clinical Biochemistry, Haukeland University Hospital, Bergen, Norway.

aAddress correspondence to this author at: LOCUS for Homocysteine and Related Vitamins, University of Bergen, N-5021 Bergen, Norway. Fax +47 55974605; e-mail klaus.meyer{at}farm.uib.no.

Background: Large cohort studies may provide sufficient power to disentangle the role of polymorphisms related to 1-carbon metabolism and chronic diseases, but they require fast, accurate, high-throughput genotyping techniques. MALDI-TOF mass spectrometry has been adapted to rapid fine mapping using various approaches for allele discrimination. We developed a genotyping method based on MALDI-TOF MS and compared assay performance for formats based on standard and mass-modified terminators.

Methods: The assay includes 20 polymorphisms of 14 genes involved in 1-carbon metabolism (BHMT 742G>A, CBS 844ins68 and 699C>T, CTH 1364G>T, DHFR del19, NOS3 –786T>C and 894G>T, FOLR1 1314G>A, MTHFD1 –105T>C and 1958G>A, MTHFR 677C>T and 1298A>C, MTR 2756A>G, MTRR 66A>G and 524C>T, SLC19A1 80G>A, SHMT1 1420C>T, TCN2 67A>G and 776C>G, and TYMS 1494del6).

Results: Missing calls were observed for 4.7% of the DNA samples, attributed to failed liquid sample handling. Highly accurate genotyping was obtained by mass-modified as well as standard ddNTPs, with an average error rate of ≤0.1% by analysis of sample duplicates. A semiquantitative approach enabled unambiguous identification of the CBS 844ins68. Cluster plots of the relative allele intensities showed allele-specific bias according to type of minisequencing terminator and revealed a potential structural variation in the BHMT gene.

Conclusions: MALDI-TOF MS–based genotyping using either standard or mass-modified terminators allows the accurate determination of single nucleotides as well as structural genetic variants. This was demonstrated with 20 polymorphisms involved in 1-carbon metabolism.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by the American Association for Clinical Chemistry.