Clinical Chemistry Siemens Point of Care - Urinalysis
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 55: 24-38, 2009. First published November 21, 2008; 10.1373/clinchem.2008.106567
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Supplemental Data
Right arrow All Versions of this Article:
clinchem.2008.106567v1
55/1/24    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Miller, W. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Miller, W. G.
(Clinical Chemistry. 2009;55:24-38.)
© 2009 American Association for Clinical Chemistry, Inc.


Reviews

Current Issues in Measurement and Reporting of Urinary Albumin Excretion

W. Greg Miller1,a, David E. Bruns2, Glen L. Hortin3, Sverre Sandberg4, Kristin M. Aakre4, Matthew J. McQueen5, Yoshihisa Itoh6, John C. Lieske7, David W. Seccombe8, Graham Jones9, David M. Bunk10, Gary C. Curhan11, Andrew S. Narva12 on behalf of the National Kidney Disease Education Program-IFCC Working Group on Standardization of Albumin in Urine

1 Department of Pathology, Virginia Commonwealth University, Richmond, VA; 2 Department of Pathology, University of Virginia Medical School, Charlottesville, VA; 3 Department of Laboratory Medicine, Warren Magnuson Clinical Center, National Institutes of Health, Bethesda, MD; 4 Laboratory of Clinical Biochemistry, Haukeland University Hospital and The Norwegian Quality Improvement of Laboratory Services in Primary Care (NOKLUS), Bergen Norway; 5 Hamilton Regional Laboratory Medicine Program, Department of Pathology and Molecular Medicine, McMaster University, Hamilton, Ontario, Canada; 6 Department of Laboratory Medicine, Asahikawa Medical College, Asahikawa, Japan; 7 Mayo Clinic Renal Function Laboratory, Department of Laboratory Medicine and Pathology, Mayo Clinic Division of Nephrology and Hypertension, Department of Internal Medicine, Rochester, MN; 8 Canadian External Quality Assessment Laboratory and Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, BC, Canada; 9 Department of Chemical Pathology, St Vincent’s Hospital Sydney, Sydney, Australia; 10 Analytical Chemistry Division, National Institute of Standards and Technology, Gaithersburg, MD; 11 Renal Division, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA; 12 National Kidney Disease Education Program, National Institute for Diabetes and Digestive Diseases, National Institutes of Health, Bethesda, MD

aAddress correspondence to this author at: PO Box 980286; Richmond, VA, 23298-0286; e-mail gmiller{at}vcu.edu.

Background: Urinary excretion of albumin indicates kidney damage and is recognized as a risk factor for progression of kidney disease and cardiovascular disease. The role of urinary albumin measurements has focused attention on the clinical need for accurate and clearly reported results. The National Kidney Disease Education Program and the IFCC convened a conference to assess the current state of preanalytical, analytical, and postanalytical issues affecting urine albumin measurements and to identify areas needing improvement.

Content: The chemistry of albumin in urine is incompletely understood. Current guidelines recommend the use of the albumin/creatinine ratio (ACR) as a surrogate for the error-prone collection of timed urine samples. Although ACR results are affected by patient preparation and time of day of sample collection, neither is standardized. Considerable intermethod differences have been reported for both albumin and creatinine measurement, but trueness is unknown because there are no reference measurement procedures for albumin and no reference materials for either analyte in urine. The recommended reference intervals for the ACR do not take into account the large intergroup differences in creatinine excretion (e.g., related to differences in age, sex, and ethnicity) nor the continuous increase in risk related to albumin excretion.

Discussion: Clinical needs have been identified for standardization of (a) urine collection methods, (b) urine albumin and creatinine measurements based on a complete reference system, (c) reporting of test results, and (d) reference intervals for the ACR.




The following articles in journals at HighWire Press have cited this article:


Home page
Ann Clin BiochemHome page
E. J Lamb, F. MacKenzie, and P. E Stevens
How should proteinuria be detected and measured?
Ann Clin Biochem, May 1, 2009; 46(3): 205 - 217.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
W. G. Miller and D. E. Bruns
Laboratory issues in measuring and reporting urine albumin
Nephrol. Dial. Transplant., March 1, 2009; 24(3): 717 - 718.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by the American Association for Clinical Chemistry.