Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 48: 380-383, 2002;
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (11)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ferrance, J.
Right arrow Articles by Landers, J. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ferrance, J.
Right arrow Articles by Landers, J. P.
Related Collections
Right arrow Molecular Diagnostics and Genetics
Right arrow Pediatric Clinical Chemistry
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 2002;48:380-383.)
© 2002 American Association for Clinical Chemistry, Inc.


Technical Briefs

Evaluation of Microchip Electrophoresis as a Molecular Diagnostic Method for Duchenne Muscular Dystrophy

Jerome Ferrance1a, Karen Snow2 and James P. Landers1,3

1 Department of Chemistry, McCormick Road, University of Virginia, Charlottesville, VA 22901

2 Molecular Genetics Laboratory, Mayo Clinic, Rochester, MN 55905

3 Department of Pathology, University of Virginia Health Science Center, Charlottesville, VA 22901

aauthor for correspondence: fax 804-982-3048, e-mail jpf3p@virginia.edu

Duchenne muscular dystrophy (DMD), a genetic disease caused by mutations in the X chromosome, is currently diagnosed by Southern blot analysis. Affected males and female carriers are identified by the detection of duplicated or deleted exons in the dystropin gene. Disadvantages of this method include the large number of fragments required for hybridization to determine genomic alterations and the time-consuming, expensive, and tedious nature of the analysis. The deletions/duplications seen in DMD tend to be located at certain "hot spot" regions of the gene, however, allowing easy detection of a great number of cases by interrogating a limited number of PCR-amplified DNA fragments.

Chamberlain and coworkers (1)(2) developed primers to amplify nine fragments from known deletion sites in a single multiplex PCR amplification. Beggs et al. (3) defined additional primers that amplify nine fragments in a second multiplex PCR. This total set of 18 fragments allows >97% of the deletions detectable by Southern blot analysis to be detected rapidly and accurately by PCR.

Analysis of the PCR fragments is most frequently carried out on slab gels, but both the presence and amount of the correctly sized fragments are important because carriers have both the mutated and wild-type gene. Many clinical laboratories that offer DMD testing do not provide carrier testing because of the technical difficulties associated with quantitative analysis. To speed analysis and automate quantification, several groups have exploited capillary electrophoresis (CE) for the separation of DMD-relevant fragments (4)(5)(6). One of the groups that reported DMD detection by CE transferred their method to an electrophoretic microdevice (6), a very rapid separation technique demonstrated to be an effective tool for use in clinical analyses (7)(8)(9)(10)(11)(12)(. . . [Full Text of this Article]


Acknowledgments


References




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
S. F.Y. Li and L. J. Kricka
Clinical Analysis by Microchip Capillary Electrophoresis
Clin. Chem., January 1, 2006; 52(1): 37 - 45.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
C.-C. Hung, Y.-N. Su, C.-Y. Lin, C.-C. Yang, W.-T. Lee, S.-C. Chien, W.-L. Lin, and C.-N. Lee
Denaturing HPLC Coupled with Multiplex PCR for Rapid Detection of Large Deletions in Duchenne Muscular Dystrophy Carriers
Clin. Chem., July 1, 2005; 51(7): 1252 - 1256.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the American Association for Clinical Chemistry.