To the Editor:
Cardiac troponins (I and T) represent a major improvement in the biochemical approach to the detection and evaluation of myocardial damage (1)(2). Here, we describe a case in which the measurement of cardiac troponin I (cTnI) gave erroneous clinical information because of interference caused by the presence of a macrocomplex.
The patient, a 78-year-old Caucasian woman with a pacemaker, had a long-standing history of cardiac disease, including a myocardial infarction 1 year before (July 1999), transient ischemic episodes with chest pain, and mitral valve failure. On July 22, 2000, the patient was admitted to the cardiac intensive care unit for an episode of chest pain and dyspnea. On admission, no significant electrocardiographic alterations were found. Biochemical markers were measured on several occasions (e.g., Table 1
). Reference values were according to the manufacturers and confirmed in our population. At admission, cTnI and myoglobin (RxL Dimension; Dade-Behring) were increased (1.0 and 96 µg/L, respectively; reference values <0.05 and <70 µg/L), but creatine kinase MB (CK-MB) was not (2
References
The following articles in journals at HighWire Press have cited this article:
![]() |
K. B. Wallace, E. Hausner, E. Herman, G. D. Holt, J. T. Macgregor, A. L. Metz, E. Murphy, I.Y. Rosenblum, F. D. Sistare, and M. J. York Serum Troponins as Biomarkers of Drug-Induced Cardiac Toxicity Toxicol Pathol, January 1, 2004; 32(1): 106 - 121. [PDF] |
||||
![]() |
T. J. DeMartini and H. S. Loeb Coronary Artery Disease and the Acute Coronary Syndrome Ann Intern Med, December 2, 2003; 139(11): W-82 - W-82. [Full Text] [PDF] |
||||
![]() |
S. Eriksson, M. Junikka, P. Laitinen, K. Majamaa-Voltti, H. Alfthan, and K. Pettersson Negative Interference in Cardiac Troponin I Immunoassays from a Frequently Occurring Serum and Plasma Component Clin. Chem., July 1, 2003; 49(7): 1095 - 1104. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |