Technical Briefs |
1 Bernhard-Nocht Institute of Tropical Medicine, National Reference Centre for Tropical Infections, 20359 Hamburg, Germany
aaddress correspondence to this author at: Bernhard Nocht Institute of Tropical Medicine, Bernhard-Nocht-Strasse 74, 20359 Hamburg, Germany; fax 49-40-42818378, e-mail drosten@bni-hamburg.de
| The first 300 words of the full text of this article appear below. |
PCR is widely used in clinical laboratories to diagnose pulmonary, extrapulmonary, and disseminated tuberculosis. A multitude of primer pairs have been successfully applied, one of which has been studied most extensively because it is included in the Roche Amplicor MTB assay, the only Food and Drug Administration-cleared PCR-based test for clinical detection of Mycobacterium tuberculosis (1)(2)(3). The test amplifies a 584-bp fragment of the 16s rDNA of all mycobacteria and identifies members of the M. tuberculosis complex (MTC) by hybridization of a specific DNA probe. However, the hybridization step extends the turnaround time of this test, and obligatory license fees render it unaffordable for application in experimental studies or resource-limited settings.
Real-time detection technology has made it possible to establish noncommercial, probe-based PCR systems that provide stable operation, low contamination risk, and semiautomated interpretation of results (4)(5)(6)(7)(8)(9)(10)(11). We therefore aimed at adapting the Roche Amplicor assay to a real-time PCR protocol.
We did not modify the primers of the Amplicor test because of their demonstrated performance; thus, only the detection probe was adapted to the requirements of real-time PCR. Classic real-time probes [5'-nuclease, "TaqMan" (12)] require cleavage by Taq polymerase (13), which could not be accomplished efficiently in our assay because the amplicon was too long and the only probe binding site specific for MTC was too distant from any of the primers (9)(12)(14). As an alternative approach, we chose a pair of fluorescence resonance energy transfer (FRET) probes that do not have to be cleaved, making them less dependent on the above-mentioned factors (15). On neighboring hybridization to the target DNA, an excited FRET probe
The following articles in journals at HighWire Press have cited this article:
![]() |
S. Burggraf, U. Reischl, N. Malik, M. Bollwein, L. Naumann, and B. Olgemoller Comparison of an Internally Controlled, Large-Volume LightCycler Assay for Detection of Mycobacterium tuberculosis in Clinical Samples with the COBAS AMPLICOR Assay J. Clin. Microbiol., April 1, 2005; 43(4): 1564 - 1569. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |