Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 50: 1080-1082, 2004; 10.1373/clinchem.2004.033183
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (3)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cradic, K. W.
Right arrow Articles by Grebe, S. K.G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cradic, K. W.
Right arrow Articles by Grebe, S. K.G.
Related Collections
Right arrow Molecular Diagnostics and Genetics
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 2004;50:1080-1082.)
© 2004 American Association for Clinical Chemistry, Inc.


Technical Briefs

Substitution of 3'-Phosphate Cap with a Carbon-Based Blocker Reduces the Possibility of Fluorescence Resonance Energy Transfer Probe Failure in Real-Time PCR Assays

Kendall W. Cradic1, Jason E. Wells2, Lindsay Allen2, Kent E. Kruckeberg1, Ravinder J. Singh1 and Stefan K.G. Grebe1,3,a

Departments of1 Laboratory Medicine and Pathology and3 Medicine, Mayo Clinic, Rochester, MN;2 Idaho Technology Inc., Salt Lake City, UT

aaddress correspondence to this author at: Endocrine Laboratory, Hilton 730C, Mayo Clinic, 200 1st St. SW, Rochester, MN 55905; fax 507-284-9758, e-mail grebs@mayo.edu

The first 300 words of the full text of this article appear below.

During the last decade, research and clinical use of real-time PCR applications has continued to grow in importance (1). Many laboratories that use real-time PCR with fluorescent probes experience an unexplained loss of probe fluorescence at some stage, in particular with pairs of fluorescence resonance energy transfer (FRET) probes. Photobleaching is often assumed to be the cause. Structural integrity of the oligonucleotides is also a major factor, and its loss has been shown to correlate with repeated freeze–thaw cycles (2). Laboratories guard against these two problems by aliquoting probes and protecting them from light. Despite these precautions, inexplicable FRET probe failures are still observed. In one recent such case, we were able to determine an additional mechanism for FRET probe failure: loss of the phosphate cap from the 3' end of a probe. To our knowledge, this has not been described previously. Our studies revealed that this may be a common and important problem, intrinsic to 3'-phosphate-blocking chemistry. We also found that alternative terminating groups may be a preferable option to 3'-phosphate blocking.

A 3-nmol/L synthesis-scale LightCyclerTM hybridization probe set was purchased from Idaho Technology Inc. Biochem in April 2003. As is common practice, the manufacturer produced a large-scale synthesis and, after shipping our order, archived the remainder for a possible future reorder. The first half of the batch ({alpha}-probe set) was sent immediately, whereas the second half (ß-probe set) was stored lyophilized for 6 months at –20 °C and then shipped with our next order.

Oligonucleotides from the first shipment were used in PCR reactions in a LightCycler with satisfactory results. PCR conditions were as follows: 1x LightCycler FastStart DNA Master Hybridization Probe Mix (Roche Diagnostics), MgCl2 (final concentration, 3.5 mM), 0.5 µM each of the forward (5'-GGCCTTTCTGAAGCAAG-3') and reverse (5'-GACGATTTCTTATTTCACAGCTCC-3') primers, 0.2 . . . [Full Text of this Article]




The following articles in journals at HighWire Press have cited this article:


Home page
Nucleic Acids ResHome page
C. N. Gundry, S. F. Dobrowolski, Y. R. Martin, T. C. Robbins, L. M. Nay, N. Boyd, T. Coyne, M. D. Wall, C. T. Wittwer, and D. H.-F. Teng
Base-pair neutral homozygotes can be discriminated by calibrated high-resolution melting of small amplicons
Nucleic Acids Res., June 1, 2008; 36(10): 3401 - 3408.
[Abstract] [Full Text] [PDF]


Home page
J. Mol. Diagn.Home page
S. Dames, R. L. Margraf, D. C. Pattison, C. T. Wittwer, and K. V. Voelkerding
Characterization of Aberrant Melting Peaks in Unlabeled Probe Assays
J. Mol. Diagn., July 1, 2007; 9(3): 290 - 296.
[Abstract] [Full Text] [PDF]


Home page
J. Mol. Diagn.Home page
M. T. Seipp, J. D. Durtschi, M. A. Liew, J. Williams, K. Damjanovich, G. Pont-Kingdon, E. Lyon, K. V. Voelkerding, and C. T. Wittwer
Unlabeled Oligonucleotides as Internal Temperature Controls for Genotyping by Amplicon Melting
J. Mol. Diagn., July 1, 2007; 9(3): 284 - 289.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Association for Clinical Chemistry.