Clinical Chemistry Siemens Point of Care - Urinalysis
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 51: 635-636, 2005; 10.1373/clinchem.2004.044255
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zhong, X. Y.
Right arrow Articles by Hahn, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zhong, X. Y.
Right arrow Articles by Hahn, S.
Related Collections
Right arrow Molecular Diagnostics and Genetics
(Clinical Chemistry. 2005;51:635-636.)
© 2005 American Association for Clinical Chemistry, Inc.


Technical Briefs

Circulatory Corticotropin-Releasing Hormone mRNA Concentrations Are Increased in Women with Preterm Delivery But Not in Those Who Respond to Tocolytic Treatment

Xiao Yan Zhong1, Wolfgang Holzgreve1, Irene Hoesli2 and Sinuhe Hahn1,a

1 Laboratory for Prenatal Medicine, University Women’s Hospital, and Department of Research, University Hospital Basel, Basel, Switzerland;2 University Women’s Hospital, University Hospital Basel, Basel, Switzerland;

aaddress correspondence to this author at: Laboratory for Prenatal Medicine, University Women’s Hospital, University Hospital Basel, Spitalstrasse 21, CH-4031 Basel, Switzerland; fax 41-61-265-9399, e-mail shahn@uhbs.ch

The first 20% of the full text of this article appears below.

Several studies using quantitative real-time PCR to measure fetal DNA and mRNA in maternal plasma have suggested that their concentrations could indicate the presence of certain pregnancy-related disorders or predispositions to them (1). Significant increases in the median concentration of cell-free fetal DNA have been reported in pregnancies bearing aneuploid fetuses (2)(3), in those affected by or at risk for preeclampsia (4)(5)(6)(7)(8), or those with preterm labor (9). Fetally derived corticotropin-releasing hormone (CRH) mRNA is reportedly increased in pregnancies with manifest preeclampsia (10), and human chorionic gonadotropin ß-subunit mRNA has been reported to be increased in pregnancies with aneuploid fetuses (11).

In this study, we measured CRH mRNA by a real-time quantitative reverse transcription-PCR assay (10)(12) in women with preterm labor. Preterm delivery remains a leading cause of perinatal mortality, has an unchanged incidence of almost 7% over the past decade (13)(14), and has no known etiology. No test . . . [Full Text of this Article]




The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
X. Y. Zhong, S. Gebhardt, R. Hillermann, K. C. Tofa, W. Holzgreve, and S. Hahn
Parallel Assessment of Circulatory Fetal DNA and Corticotropin-Releasing Hormone mRNA in Early- and Late-Onset Preeclampsia
Clin. Chem., September 1, 2005; 51(9): 1730 - 1733.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the American Association for Clinical Chemistry.