Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 43: 913-914, 1997;
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (55)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Swan, S. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Swan, S. K.
Related Collections
Right arrow General Clinical Chemistry
(Clinical Chemistry. 1997;43:913-914.)
© 1997 American Association for Clinical Chemistry, Inc.


Editorials

The Search Continues—An Ideal Marker of GFR

Suzanne K. Swan

Division of Nephrology, Hennepin County Medical Center, 701 Park Ave., Minneapolis, MN 55415, Fax 612-347-2003

The glomerular filtration rate (GFR) is generally considered the best measure of renal function despite the fact that the kidney performs an array of duties, including salt and water balance, erythropoiesis, bone metabolism, electrolyte homeostasis, and blood pressure control. GFR is traditionally measured as the renal clearance of a particular substance from plasma and is expressed as the volume of plasma that can be completely cleared of that substance in a unit of time. The ideal marker for GFR determinations would appear endogenously in the plasma at a constant rate, be freely filtered at the glomerulus, be neither reabsorbed nor secreted by the renal tubule, and undergo no extrarenal elimination. Although the ideal marker for measuring GFR has yet to be found, these characteristics can be useful benchmarks for comparing the advantages and disadvantages of new methods for GFR quantification.

Measurement of urea marked the beginning of efforts to quantify renal function with its isolation by Rouelle in 1773 (1). Subsequently, Strauss introduced blood urea as a diagnostic test for renal disease in 1903. The concept of clearance as a measure of renal function followed in 1929 (2) and was subsequently extended to creatinine in the early 1930s (1).

Blood urea nitrogen (BUN) concentration is generally recognized to be a poor measure of renal function, in that it possesses few of the attributes of an ideal marker of GFR. It is produced at variable rates, is affected by a number of disease states (congestive heart failure, malnutrition, hyperalimentation), and undergoes renal tubular reabsorption.

Serum creatinine determination has become a mainstay in the standard laboratory profile of renal function because of its convenience and low cost. Nevertheless, serum creatinine remains a crude marker of GFR. Creatinine concentrations are insensitive to detection of mild to moderate reductions in GFR. This is due to the nonlinear relation between concentrations of creatinine in the blood and GFR. For example, a change in serum creatinine from 53 µmol/L (0.6 mg/dL) to 106 µmol/L (1.2 mg/dL) reflects ~50% decline in GFR despite the latter value falling within the normal range. If a previous baseline value for serum creatinine did not exist for comparison, a value of 106 (1.2) would not draw clinical attention to a potential reduction in GFR. Nephrologists are often consulted as an emergency when a patient's creatinine rises from 442 µmol/L (5 mg/dL) to 619 µmol/L (7 mg/dL), which may be far less critical in that GFR has fallen from ~20 mL/min to 15 mL/min. Creatinine is a metabolic product of creatine and phosphocreatine found in muscle and, as such, reflects muscle mass and varies little from day to day (3). However, age- and gender-associated differences in creatinine production are proportional to muscle mass, and creatinine generation can vary significantly in a given individual over time when muscle mass changes [4, 5]. Creatinine is small, circulates unbound to plasma proteins, and is freely filtered at the glomerulus but undergoes tubular secretion into the urinary space (6). Tubular secretion of creatinine is not constant and varies, not only within an individual, but between individuals. Further, the proportion of total renal creatinine excretion due to tubular secretion increases with decreasing renal function. This could lead to further amplification of the overestimation of GFR, which creatinine clearance represents (7). Several substances can interfere with laboratory measurements of creatinine. Glucose, uric acid, ketones, plasma proteins, and cephalosporins may lead to falsely high creatinine values when the Jaffe colorimetric method is used [8, 9]. Creatinine clearance determinations involving timed urine collections may provide greater accuracy but are difficult for patients to perform, time-consuming, and impractical for routine use. Inaccuracies may still arise if the specimens represent "under-" or "over"collections.

Clearance of various radionuclide markers, including 99mTc-labeled diethylenetriaminepentaacetic acid (DTPA), 51Cr-labeled EDTA, and 125I-labeled iothalamate, have been used as reliable measures of glomerular filtration but are costly, involve special specimen handling, and require radiation exposure.

Thus, a method to quantify GFR that is accurate, efficient, and safe continues to elude clinicians. In recent years, O'Reilly et al. reported that the plasma "decay" or disappearance of iohexol represented a new method of measuring GFR (10). Later reports proposed that iohexol clearance replace inulin clearance as the new "gold standard" of GFR determinants, and numerous investigators have reported similar results with iohexol (11)(12)(13)(14). Additionally, my colleagues and I reported that plasma iohexol clearance was a safe, accurate, and efficient way to measure residual renal function in hemodialysis patients to better tailor their dialysis prescription (15). Drawbacks to iohexol-derived GFR include the need for a blood draw 4 to 6 h after iohexol administration and a history of iodine allergy precluding its use.

In 1985, Simonsen et al. reported that the reciprocal of serum concentrations of cystatin C correlated closely with 51Cr-labeled EDTA-derived GFR determinations (16). A number of subsequent reports have confirmed that cystatin C is an accurate marker of GFR (17)(18). A small protein derived from the cystatin superfamily of cysteine protease inhibitors (19), cystatin C is produced by all nucleated cells and its production rate is unaltered in inflammatory conditions; glomerular filtration removes cystatin C from the circulation. Thus, cystatin C meets many of the criteria of an ideal GFR marker. Early methods of cystatin C quantification (enzyme-amplified single radial immunodiffusion), however, were slow, impractical for single sample analysis, and did not allow automation. In this issue of Clinical Chemistry, Finney et al. (20) describe a new particle-enhanced immunonephelometry method for cystatin C determinations, and Filler et al. (21) report that cystatin C may represent a better marker of GFR than creatinine when measured by a particle-enhanced turbidimetric assay. The advantages of cystatin C include its endogenous nature, thus obviating the need for administration of an exogenous marker such as iohexol. Similarly, the risk of allergic reaction would not exist with cystatin C.

The rapid development of therapeutic interventions involving transplantation, antimicrobial therapy, oncology, and intensive care medicine has generated an increasing demand for fast, accurate, and simple methods for GFR determinations. In theory, cystatin C measurements in plasma represent a valuable contribution to diagnostic practices, but further clinical experience with this methodology will be necessary before its role in clinical practice can be validated.


References

  1. Smith HW. The kidney: structure and function in health and disease 1951:63-66 Oxford University Press New York. .
  2. Möller E, McIntosh JF, Van Slyke DD. Studies of urea excretion. II. Relationship between urine volume and the rate of urea excretion by normal adults. J Clin Invest 1929;6:427-465.
  3. Heymsfield SB, Arteaga C, McManus C, Smith J, Moffitt S. Measurement of muscle mass in humans: validity of the 24-hour urinary creatinine method. Am J Clin Nutr 1983;37:478-494. [Abstract/Free Full Text]
  4. James GD, Sealey JE, Alderman M, Ljungman S, Mueller FB, Pecker MS, Laragh JH. A longitudinal study of urinary creatinine and creatinine clearance in normal subjects: race, sex, and age differences. Am J Hypertens 1988;1:124-131. [Web of Science][Medline] [Order article via Infotrieve]
  5. Fitch CD, Sinton DW. A study of creatine metabolism in diseases causing muscle wasting. J Clin Invest 1964;43:444-452.
  6. Shannon JA. The renal excretion of creatinine in man. J Clin Invest 1935;14:403-410.
  7. Levey AS, Berg RL, Gassman JJ, Hall PM, Walker WG. Creatinine filtration, secretion and excretion during progressive renal disease. Kidney Int 1989;36(Suppl 27):S73-S80.
  8. Young DS. Effects of drugs on clinical laboratory tests, 3rd ed 1990:356-357 AACC Press Washington, DC. .
  9. Gerard SK, Khayam-Bashi H. Characterization of creatinine error in ketotic patients: a prospective comparison of alkaline picrate methods with an enzymatic method. Am J Clin Pathol 1985;84:659-664. [Web of Science][Medline] [Order article via Infotrieve]
  10. O'Reilly PH, Brooman PJC, Martin PJ. Accuracy and reproducibility of a new contrast clearance method for the determination of glomerular filtration. Br Med J 1986;293:234-236.
  11. Brown SCW, O'Reilly PH. Iohexol clearance for the determination of glomerular filtration rate in clinical practice: evidence for a new gold standard. J Urol 1991;146:675-679. [Web of Science][Medline] [Order article via Infotrieve]
  12. Lindblad HG, Berg UB. Comparative evaluation of iohexol and inulin clearance for glomerular filtration rate determinations. Acta Paediatr 1994;83:418-422. [Web of Science][Medline] [Order article via Infotrieve]
  13. Stake G, Monn E, Rootwelt K, Grönberg T, Monclair T. Glomerular filtration rate estimated by x-ray fluorescence technique in children: comparison between the plasma disappearance of 99Tcm-DTPA and iohexol after urography. Scand J Clin Lab Invest 1990;50:161-167. [Web of Science][Medline] [Order article via Infotrieve]
  14. Lewis R, Kerr N, Van Buren C, Lowry P, Sandler C, Frazier OH, et al. Comparative evaluation of urographic contrast media, inulin, and 99mTc-DTPA clearance methods for determination of glomerular filtration rate in clinical transplantation. Transplantation 1989;48:790-796. [Web of Science][Medline] [Order article via Infotrieve]
  15. Swan SK, Halstenson CE, Kasiske BL, Collins AJ. Determination of residual renal function with iohexol clearance in hemodialysis patients. Kidney Int 1996;49:232-235. [Web of Science][Medline] [Order article via Infotrieve]
  16. Simonsen O, Grubb A, Thysell H. The blood serum concentration of cystatin C ({gamma}-trace) as a measure of the glomerular filtration rate. Scand J Clin Lab Invest 1985;45:97-101. [Web of Science][Medline] [Order article via Infotrieve]
  17. Newman DJ, Thakkar H, Edwards RG, Wilkie M, White T, Grubb AO, Price CP. Serum cystatin C measured by automated immunoassay: a more sensitive marker of changes in GFR than serum creatinine. Kidney Int 1995;47:312-318. [Web of Science][Medline] [Order article via Infotrieve]
  18. Kasiske BL, Kalil RSN, Lee HS, Rao KV. Histopathologic findings associated with a chronic progressive decline in renal allograft function. Kidney Int 1991;40:514-524. [Web of Science][Medline] [Order article via Infotrieve]
  19. Grubb A, Lofberg H. Human gamma-trace, a basic microprotein: aminoacid sequence and presence in the adenohypophysis. Proc Natl Acad Sci U S A 1982;79:3024-3027. [Abstract/Free Full Text]
  20. Finney H, Newman DJ, Gruber W, Merle P, Price CP. Initial evaluation of cystatin C measurement by particle-enhanced immunonephelometry on the Behring nephelometer systems (BNA, BN II). Clin Chem 1997;43:1016-1022. [Abstract/Free Full Text]
  21. Filler G, Witt I, Priem F, Ehrich JHH, Jung K. Are cystatin C and ß2-microglobulin better markers than serum creatinine for prediction of a normal glomerular filtration rate in pediatric subjects?. Clin Chem 1997;43:1077-1078. [Free Full Text]



The following articles in journals at HighWire Press have cited this article:


Home page
Am. J. Roentgenol.Home page
P.-A. Poletti, P. Saudan, A. Platon, B. Mermillod, A.-M. Sautter, B. Vermeulen, F. P. Sarasin, C. D. Becker, and P.-Y. Martin
IV N-Acetylcysteine and Emergency CT: Use of Serum Creatinine and Cystatin C as Markers of Radiocontrast Nephrotoxicity
Am. J. Roentgenol., September 1, 2007; 189(3): 687 - 692.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
W. Koenig, D. Twardella, H. Brenner, and D. Rothenbacher
Plasma Concentrations of Cystatin C in Patients with Coronary Heart Disease and Risk for Secondary Cardiovascular Events: More than Simply a Marker of Glomerular Filtration Rate
Clin. Chem., February 1, 2005; 51(2): 321 - 327.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Soc. Nephrol.Home page
U. Hoffmann, M. Fischereder, B. Kruger, W. Drobnik, and B. K. Kramer
The Value of N-Acetylcysteine in the Prevention of Radiocontrast Agent-Induced Nephropathy Seems Questionable
J. Am. Soc. Nephrol., February 1, 2004; 15(2): 407 - 410.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
G.D. Tan, A.V. Lewis, T.J. James, P. Altmann, R.P. Taylor, and J.C. Levy
Clinical Usefulness of Cystatin C for the Estimation of Glomerular Filtration Rate in Type 1 Diabetes: Reproducibility and accuracy compared with standard measures and iohexol clearance
Diabetes Care, November 1, 2002; 25(11): 2004 - 2009.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
O. F. Laterza, C. P. Price, and M. G. Scott
Cystatin C: An Improved Estimator of Glomerular Filtration Rate?
Clin. Chem., May 1, 2002; 48(5): 699 - 707.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
L. Risch, R. Herklotz, A. Blumberg, and A. R. Huber
Effects of Glucocorticoid Immunosuppression on Serum Cystatin C Concentrations in Renal Transplant Patients
Clin. Chem., November 1, 2001; 47(11): 2055 - 2059.
[Full Text] [PDF]


Home page
JNMHome page
K. Itoh
Determination of Glomerular Filtration Rate by Means of Newly Developed Plastic Scintillation Counter Both With and Without Dilution Procedures
J. Nucl. Med., October 1, 2001; 42(10): 1484 - 1488.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
H. Stowe, D. Lawrence, D. J. Newman, and E. J. Lamb
Analytical Performance of a Particle-enhanced Nephelometric Immunoassay for Serum Cystatin C Using Rate Analysis
Clin. Chem., August 1, 2001; 47(8): 1482 - 1485.
[Full Text] [PDF]


Home page
Am. J. Clin. Nutr.Home page
J. B Ubbink
Metabolic markers of vitamin nutritional status
Am. J. Clinical Nutrition, November 1, 1999; 70(5): 789 - 790.
[Full Text]


Home page
Clin. Chem.Home page
F. Priem, H. Althaus, M. Birnbaum, P. Sinha, H. S. Conradt, and K. Jung
ß-Trace Protein in Serum: A New Marker of Glomerular Filtration Rate in the Creatinine-Blind Range
Clin. Chem., April 1, 1999; 45(4): 567 - 568.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
D. Stickle, B. Cole, K. Hock, K. A. Hruska, and M. G. Scott
Correlation of plasma concentrations of cystatin C and creatinine to inulin clearance in a pediatric population
Clin. Chem., June 1, 1998; 44(6): 1334 - 1338.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (55)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Swan, S. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Swan, S. K.
Related Collections
Right arrow General Clinical Chemistry


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS