Clinical Chemistry 43: 1105-1107, 1997;
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (9)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Eby, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Eby, C.
Related Collections
Right arrow Laboratory Management
Right arrow Hemostasis and Thrombosis
(Clinical Chemistry. 1997;43:1105-1107.)
© 1997 American Association for Clinical Chemistry, Inc.


Editorials

Standardization of APTT Reagents for Heparin Therapy Monitoring: Urgent or Fading Priority?

Charles Eby

Department of Pathology, Saint Louis University Health Sciences Center, 3635 Vista Ave. at Grand Blvd., St. Louis, MO 63110, ebycs@sluh_his.sluh.edu

Tremendous improvements have been made in the outcomes of patients with acute venous thromboembolic events (VTE) since Murray et al. successfully administered heparin to postsurgery patients in 1937 (1). Advances include accurate methods for diagnosis of deep vein thromboses (DVT) and pulmonary emboli (PE); effective regimens for initial and long-term anticoagulation; and wide acceptance of a system for standardization of thromboplastin sensitivities to the anticoagulant effects of warfarin (International Normalized Ratio; INR). In this issue of Clinical Chemistry, van den Besselaar et al. (2) address an unresolved aspect of anticoagulation therapy: standardization of activated partial thromboplastin time (APTT) reagents for monitoring heparin therapy.

Heparin is a glycosaminoglycan extracted from mast cells of porcine intestinal mucosa or bovine lung. It is composed of long chains of alternating D-glucuronic acid and N-acetyl-D-glucosamine sugar residues, which undergo a series of chemical modifications, primarily sulfation, leading to unique pentasaccharide sequences that serve as a binding site for antithrombin III (AT III) (3). The anticoagulant effect of heparin is mediated through this interaction, which markedly accelerates the rate of AT III inhibition of thrombin (factor IIa) and factor Xa. Heparin polysaccharides are heterogeneous in length and anticoagulation activity and range in mass from 5000 to 30 000 kDa. Commercial preparations are calibrated in USP units, 1 unit being defined as the quantity that prevents 1.0 mL of citrated sheep plasma from clotting for 1 h after the addition of 0.2 mL of 10 g/L CaCl2 (3).

Low-molecular-weight heparins (LMWH) are produced from unfractionated heparin to yield smaller polysaccharides with average molecular masses of 4000–5000 kDa. These shorter molecules lose the ability to accelerate AT III inhibition of thrombin but retain the ability to catalyze factor Xa inhibition. Decreased in vivo protein binding improves LMWH bioavailability and leads to predictable anticoagulant response (4).

In 1960, Barrett and Jordan conducted the first prospective study of anticoagulation therapy, randomizing patients with pulmonary emboli to treatment with 10 000 USP units of heparin intravenous bolus every 6 h for 6 doses and an oral anticoagulant for 2 weeks, or no therapy (5). None of the 16 patients who received heparin died of a recurrent PE, compared with 5 of 19 PE-related deaths in the control group. However, one patient who received heparin died of complications from a bleeding duodenal ulcer.

Subsequently, investigators realized that the anticoagulant response to a fixed dose of heparin was variable in acutely ill patients. In an effort to administer a sufficient amount of heparin to prevent recurrent thromboembolic complications yet low enough to carry an acceptable risk of hemorrhage, therapeutic ranges based on laboratory monitoring of the anticoagulant effect of heparin were developed. A combination of clinical experience (6) and results from animal models of experimental venous stasis and thrombosis (7)(8) supported a therapeutic target of doubling the whole-blood clotting time or prolongation of the APTT to 1.5 to 2.5 times the laboratory mean control. The APTT quickly became the accepted test for monitoring heparin activity because of its convenience, precision, wide availability, and adaptability to automated instruments.

A correlation between plasma heparin activity, APTT prolongation, and thrombus growth, established in 1977 by Chui et al., has become a cornerstone of heparin therapy (9). They measured fibrin accumulation onto a thrombus in an isolated segment of a rabbit jugular vein. Minimal additional accumulation of fibrin occurred during heparin infusion rates that produced plasma heparin activities between 0.2 and 0.4 USP unit/mL (based on protamine titration) and APTTs of 1.5 to 2.5 times baseline. Higher heparin concentrations produced minor additional reductions in fibrin accretion and longer bleeding times from jugular vein punctures.

Over the last two decades, clinical investigators have conducted a series of prospective, randomized clinical trials comparing different anticoagulation strategies for the management of patients with acute VTEs. Measured outcomes included recurrent thromboembolic events and bleeding. These studies have convincingly shown that:

1. Initial treatment with an oral anticoagulant alone leads to more recurrent VTEs than does combination therapy with heparin (10).

2. Recurrence rates are higher when subtherapeutic APTTs persist for >24–48 h after initiation of heparin (11).

3. Five days of therapeutic continuous intravenous heparin therapy is as effective as 10 days when warfarin is begun on day 1 rather than day 5 (12).

4. Nomograms for heparin dosing (intravenous bolus, then continuous infusion) increase the proportion of patients with APTTs above a minimal therapeutic threshold and improve outcome (lower recurrence rates) (13).

5. Weight-based dosing of SQ LMWH without laboratory monitoring is as efficacious as continuous infusion of unfractionated heparin with APTT therapeutic monitoring (14).

The efficacy rates of continuous heparin infusions were similar in these clinical trials (VTE recurrence ~6% (4), bleeding complications <5% (15)). APTT therapeutic ranges were usually equivalent to plasma heparin activities of 0.2–0.4 USP units/mL by protamine titration, and average initial rates of heparin infusion were >=30 000 units/24 h (4).

However, reliance on a 1.5 to 2.5 times control APTT therapeutic range to guide heparin dosing in routine clinical practice is fraught with many sources of variability, as was the historical 2–2.5 times control PT target for oral anticoagulation therapy. First, the APTT is a global test of coagulation; it is affected by many variables in addition to heparin, including coagulopathies, inhibitors, and increases of factor VIII and fibrinogen. Secondly, there is no agreement on what value should be used for the denominator of APTT ratios: mean or upper limit APTT of a reference range for normal, or a patient's pretreatment APTT. Most importantly, commercial APTT reagent sensitivities to heparin vary widely (16)(17). Factors involved are differences in the relative and absolute concentrations of polar phospholipids, as well as the use of different activators (kaolin, silica) in the APTT reagent. Finally, some investigators note that different instruments and clot detection methods contribute to the variability of APTT reagent sensitivity to heparin (18).

The most compelling demonstration of the potential risk for subtherapeutic dosing of heparin based on a 1.5–2.5-fold prolongation over mean normal control APTT was provided by Brill-Edwards et al. (19). Five different commercial APTT reagents were calibrated against plasmas with ex vivo heparin activities of 0.2–0.4 USP units/mL by protamine titration to determine therapeutic ranges for APTT ratios. The ranges varied from 1.8–2.5 to 2.6–4.2 USP units/mL. Lot-to-lot variation of heparin sensitivity was also reported for one brand of APTT reagent.

Several approaches have been proposed to improve the therapeutic monitoring of heparin. Laboratories can calibrate the therapeutic range for APTT ratio for each reagent–instrument system to be equivalent to a heparin concentration of 0.2–0.4 USP units/mL by protamine titration or to 0.3–0.7 units/mL anti-Factor Xa activity (20). There are obstacles to this approach, in addition to the required time, expense, and expertise. Addition of heparin in vitro to pooled normal plasma is not recommended because this produces unreliable and typically low APTT therapeutic ranges, compared with calibrations performed with plasma samples obtained from patients receiving heparin. Finally, laboratory directors must convince clinicians to change their practice of dosing heparin on the basis of a 1.5–2.5 APTT ratio in favor of a new, less familiar, range.

Newer automated coagulation analyzers can measure heparin activity directly (as anti-factor Xa activity). Their turnaround times are acceptable for patient management needs, but these assays are currently too expensive to consider as a replacement for the APTT. Finally, a reference APTT reagent and method could be established along with a formula to compare the heparin sensitivity of commercial reagents against the standardized values. This would permit the reporting of normalized APTT ratios.

Van den Besselaar et al. previously demonstrated that liposomes containing synthetic dioleoylphosphatidylserine, dioleoylphosphatidylcholine, and dioleoylphosphatylethanolamine could be produced that behaved like a commercial biological APTT reagent (21). Now, they report their analysis of another synthetic APTT reagent, 91/558, that has been lyophilized and stored at -70 °C for 4 years (2). Modifications include substitution of silica for kaolin, a relative decrease in the proportion of phosphatidylserine used, and an increase in total phospholipid concentration (from 40 to 67 nmol/L). Comparing this material with two biological APTT reagents for sensitivity to in vitro and ex vivo heparinized plasmas, the authors observed linear relationships with high correlation coefficients between 91/558 and Automated APTT (Organon Teknika) but not with 91/558 and "Manchester reagent." They speculate that this may be due to a different activator, kaolin, in the Manchester reagent. However, it would be premature to assume that a synthetic APTT reagent can be used to calibrate the heparin sensitivity of other APTT reagents as long as the same activator is used. Other investigators have been disappointed when they attempted to calibrate heparin sensitivity of APTT reagents against an arbitrary commercial reference reagent (22)(23).

A synthetic phospholipid such as 91/588 could potentially be a reference APTT reagent. But is an APTT-INR system an urgent need? I do not believe it is. Instead, manufacturers should first work with clinical laboratories to develop simple, cost-effective strategies for determining reagent/instrument-specific APTT therapeutic ranges calibrated against ex vivo plasma heparin activity. The recent introduction of commercial synthetic APTT reagents with minimal lot-to-lot variation in heparin sensitivity is an important advance. Finally, LMWH will probably soon supplant unfractionated heparin for treatment of acute VTEs, pending FDA approval—a development that is desirable for both clinical (14) and economic reasons (24). When that happens, standardization of APTT monitoring of heparin therapy may become an historical rather than urgent problem.

Nevertheless, cogent reasons support development of a reference APTT reagent. The APTT is a valuable screening test for detecting deficiencies of factor VIII and IX in patients with positive bleeding histories or for detecting nonspecific inhibitors (lupus anticoagulants) in patients with clinical findings suggestive of anti-phospholipid antibody syndrome. However, the lack of commercial APTT reagent standardization for these functions is frustrating. A reference synthetic phospholipid plus activator APTT reagent designed to be sensitive for the detection of patients with mild hemophilia, von Willebrand disease, and lupus anticoagulants would be an important advance. Manufacturers could then develop second-generation synthetic reagents nearly identical to the reference preparation. Sensitivity to the anticoagulant effect of unfractionated heparin could be a specification of a synthetic APTT reagent standard, as well. Although LMWH may eventually replace heparin or be replaced itself by a synthetic analog, such evolutions in clinical practice take longer than one might predict.

Van den Besselaar and colleagues have established the foundation for an important initiative that, when completed, will improve the quality of clinical laboratory hemostasis services.


References

  1. Murray D, Jacques L, Perret T, Best C. Heparin and thrombosis of veins. Surgery 1937;2:163-185. [Web of Science]
  2. Van den Besselaar AMPH, Neuteboom J, Meeuwisse-Braun J, Bertina RM. Preparation of a lyophilized partial thromboplastin time reagent composed of synthetic phospholipids: usefulness for monitoring heparin therapy. Clin Chem 1997;43:1215-1222. [Abstract/Free Full Text]
  3. Majerus PW, Brose GJ, Miletich JP, Tollefsen PM. Anticoagulant, thrombolylic, and antiplatelet drugs. In: Hardman JG, Limbrid LE, eds., Goodman and Gilman's The pharmacological bases of therapeutics, 9th ed, New York: McGraw Hill, 1996:1341–6..
  4. Hirsh J, Raschke R, Warkentin TE, Dalen JE, Deykin D, Poller E, et al. Heparin: mechanism of action, pharmacokinetics, dosing considerations, monitoring, efficacy, and safety. Chest 1995;108(Suppl 4):258S-275S. [Free Full Text]
  5. Barritt DW, Jordan SC. Anticoagulant drugs in the treatment of pulmonary embolism. A controlled trial. Lancet 1960;i:1309-1312.
  6. Spector I, Corn M. Control of heparin therapy with activated partial thromboplastin times. JAMA 1967;201:157-159.
  7. Wessler S, Morris LE. Studies in intravascular coagulation IV. The effect of heparin and dicumarol on serum-induced venous thrombosis. Circulation 1955;12:553-556. [Web of Science][Medline] [Order article via Infotrieve]
  8. Zucker S, Cathey MH. Control of heparin therapy. Sensitivity of the activated partial thromboplastin time for monitoring the antithrombotic effects of heparin. J Lab Clin Med 1969;73:320-326. [Web of Science][Medline] [Order article via Infotrieve]
  9. Chiu HM, Hirsh J, Yung WL, Regoeczi E, Gent M. Relationship between the anticoagulant and antithrombotic effects of heparin in experimental venous thrombosis. Blood 1977;49:171-184. [Abstract/Free Full Text]
  10. Brandjes DPM, Heijboer H, Buller HR, et al. Acenocoumarol and heparin compared with acenocoumarol alone in the initial treatment of proximal vein thrombosis. N Engl J Med 1992;327:1485-1489. [Abstract]
  11. Hull RD, Raskob GE, Hirsh J, Jay RM, et al. Continuous intravenous heparin compared with intermittent subcutaneous heparin in the initial treatment of proximal vein thrombosis. N Engl J Med 1986;315:1109-1114. [Abstract]
  12. Hull RD, Raskob GE, Rosenbloom D, et al. Heparin for 5 days as compared with 10 days in the initial treatment of proximal venous thrombosis. N Engl J Med 1990;322:1260-1264. [Abstract]
  13. Raschke RA, Reilly BM, Guidry JR, Fontana JR, Srinivas S. The weight-based heparin dosing nomogram compared with a "standard care" nomogram. Ann Intern Med 1993;119:874-881. [Abstract/Free Full Text]
  14. Lensing AWA, Prins MH, Davidson BL, Hirsch J. Treatment of deep venous thrombosis with low-molecular-weight heparins. A meta-analysis. Arch Intern Med 1995;155:601-607. [Abstract/Free Full Text]
  15. Levine MN, Raskob G, Landefeld S, Hirsh J. Hemorrhagic complications of anticoagulant treatment. Chest 1995;108(Suppl 4):276S-290S. [Free Full Text]
  16. Kitchen S, Jennings I, Woods TAL, Preston FE. Wide variability in the sensitivity of APTT reagents for monitoring of heparin dosage. J Clin Pathol 1996;49:10-14. [Abstract/Free Full Text]
  17. Brandt JT, Triplett DA. Laboratory monitoring of heparin. Effect of reagents and instruments on the activated partial thromboplastin time. Am J Clin Pathol 1981;76(Suppl):530-537. [Web of Science][Medline] [Order article via Infotrieve]
  18. D'Angelo A, Seveso MP, D'Angelo SV, Gilardoni F, et al. Effect of clot-detection methods and reagents on activated partial thromboplastin time (APTT). Implications in heparin monitoring by APTT. Am J Clin Pathol 1990;94:297-306. [Web of Science][Medline] [Order article via Infotrieve]
  19. Brill-Edwards P, Ginsberg JS, Johnston M, Hirsh J. Establishing a therapeutic range for heparin therapy. Ann Intern Med 1993;119:104-109. [Abstract/Free Full Text]
  20. Hirsh J. Drug therapy: heparin [Review]. N Engl J Med 1991;324:1565-1575. [Web of Science][Medline] [Order article via Infotrieve]
  21. Van den Besselaar AMHP, Neuteboom J, Bertina RM. Effect of synthetic phospholipids on the response of the activated partial thromboplastin time to heparin. Blood Coagul Fibrinolysis 1993;4:895-903. [Web of Science][Medline] [Order article via Infotrieve]
  22. Ray M, Carroll P, Smith I, Hawson G. An attempt to standardize APTT reagents used to monitor heparin therapy. Blood Coagul Fibrinolysis 1992;3:743-748. [Web of Science][Medline] [Order article via Infotrieve]
  23. Reed SV, Haddon ME, Denson KWE. An attempt to standardize the APTT for heparin monitoring, using the P.T. ISI/INR system of calibration. Results of a 13 centre study. Thromb Res 1994;74:515-522. [Web of Science][Medline] [Order article via Infotrieve]
  24. Hull RD, Raskob GE, Rosenbloom D, Pineo GF, et al. Treatment of proximal vein thrombosis with subcutaneous low-molecular-weight heparin vs intravenous heparin. An economic perspective. Arch Intern Med 1997;157:289-294. [Abstract/Free Full Text]



The following articles in journals at HighWire Press have cited this article:


Home page
Eur. J. Cardiothorac. Surg.Home page
H. Gorki, V. Malinovski, and R. D.L. Stanbridge
The antiphospholipid syndrome and heart valve surgery
Eur. J. Cardiothorac. Surg., February 1, 2008; 33(2): 168 - 181.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (9)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Eby, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Eby, C.
Related Collections
Right arrow Laboratory Management
Right arrow Hemostasis and Thrombosis


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS