Clinical Chemistry 44: 2052-2054, 1998;
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (12)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Benecky, M. J.
Right arrow Articles by Kamerud, J. Q.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Benecky, M. J.
Right arrow Articles by Kamerud, J. Q.
Related Collections
Right arrow Oak Ridge Conference
(Clinical Chemistry. 1998;44:2052-2054.)
© 1998 American Association for Clinical Chemistry, Inc.


Poster Sessions

Simultaneous Detection of Multiple Analytes Using Copalis Technology: A Reduction to Practice

Michael J. Benecky, Kevin L. McKinney, Kimberly M. Peterson, and John Q. Kameruda

a author for correspondence

Coupled Particle Light Scattering (Copalis) is a homogeneous immunoassay technology that enables the simultaneous determination of multiple analytes in serum, plasma, or whole blood (1) . The Copalis system measures changes in light-scattering properties of particles when they form antibody-mediated complexes. The system can measure two types of events: polystyrene microparticle coagglutination and polystyrene-gold colloid microparticle coupling. In the first format, polystyrene microparticles are differentiated from their complexed aggregates as a function of antigen concentration or serological response. The second format measures the broadening of the microparticle light scatter histogram as gold particles are attached. In both cases, light scattering analysis is performed as particles flow singly through a finely focused laser beam.

The ability to differentiate various sizes of polystyrene microparticles allows the system to measure multiple analytes or serological responses simultaneously. This capability has been demonstrated by the ToRC assay (toxoplasma, rubella, cytomegalovirus), in which antibodies to three different infectious agents are detected simultaneously (2) . In the present work, we demonstrate the application of Copalis technology to a variety of areas of diagnostic medicine in which the simultaneous measurement of multiple analytes or variables may be advantageous, including infectious disease, autoimmunity, and reproductive endocrinology.


latex-latex format

This format is useful for detecting the presence of antibodies to infectious agents or autoantigens, which are coated onto latex microparticles. By using only forward-scatter measurement, Copalis instrumentation can distinguish between different-sized particles, as well as between monomers and aggregates. The presence of specific antibodies is detected as a reduction in the number of monomeric particles coated with the corresponding antigen (see Fig. 1A ). In addition to the aforementioned ToRC assay, we have applied this format to the diagnosis of syphilis, Epstein-Barr viral infection, and SSA/SSB autoimmunity.



View larger version (18K):
[in this window]
[in a new window]
 
Figure 1. Demonstration of latex-latex (A) and latex-gold (B) Copalis formats.

(A) Three different-sized latex particles coated with three different EBV antigens are distinguished on the basis of forward-angle light scatter (x-axis). Left, EBV-negative sample. Right, sample positive for Epstein-Barr nuclear antigen (EBNA) and early antigen (EA) antibodies. (B) Two different-sized particles are coated with either anti-LH or anti-FSH antibodies. Front, zero calibrator; middle, 0 mIU/mL LH, 150 mIU/mL FSH; back, 250 mIU/mL LH, 0 mIU/mL FSH.

The typical algorithm for syphilis testing involves first screening with a nonspecific test such as the VDRL (Venereal Disease Research Laboratory) agglutination assay, followed by confirmatory testing of positive specimens by immunofluoresence assay (IFA) or ELISA using a specific treponemal antigen (3) . By coating the treponemal antigen and a VDRL-like antigen on microparticles of different sizes, we have designed a Copalis assay that combines the screening and confirmatory tests. The Copalis syphilis assay has been evaluated by comparison with commercially available kits for treponemal (Zeus IFA and Centocor Captia ELISA) and nontreponemal (MacroVue RPR by Becton Dickinson) antigens. The relative sensitivity and specificity were as follows: treponemal: 92.2% sensitivity (n = 51), 93.6% specificity (n = 94); and nontreponemal: 94.2% sensitivity (n = 52), 97.6% specificity (n = 96).

Another area of infectious disease testing to which Copalis has been applied is Epstein-Barr serology. In this case, three different antigens from the Epstein-Barr virus (EBV) were coated onto three different sizes of polystyrene latex microparticles. The antigens represented are the Epstein-Barr nuclear antigen, the viral capsid antigen, and the early antigen. Reduction in the size of any of the three peaks indicates the presence of antibodies against the corresponding antigen. Such testing may be useful in the differentiation of new infections, immune status, and reactivation of latent infections.

The systemic autoimmune diseases are characterized by the presence of antibodies against a number of different autoantigens (4) . The simultaneous determination of these autoantibody specificities might be helpful in the differential diagnosis of diseases such as systemic lupus erythematosus, Sjogren syndrome, mixed connective tissue disease, and systemic scleroderma. The application of Copalis technology to the detection of autoantibodies is demonstrated by an assay for the simultaneous detection of antibodies to the autoantigens SSA (Ro) and SSB (La). For evaluation of the SSA Copalis assay, 23 ELISA-positive samples and 44 healthy blood-bank donors were run. Relative to ELISA, the sensitivity and specificity of the Copalis assay were 96% and 93%, respectively.


latex-gold format

Utilizing both forward-scatter and side-scatter parameters, this format is useful for the quantitative detection of analytes with greater sensitivity than that achieved using the latex-latex format. Antigen-mediated binding of colloidal gold to antibody-coated latex microparticles causes a broadening of the latex side-scatter histogram (2) . The extent of this broadening can be measured and correlated to analyte concentration (see Fig. 1BUp ).

The Latex-Gold format has been applied to the assessment of human fertility. Antibodies against different epitopes on luteinizing hormone (LH) were coated separately onto latex particles and onto colloidal gold. The same was done for follicle-stimulating hormone (FSH), using a different size of latex. When these reagents are combined and incubated with patient sample, the presence of either analyte leads to formation of a "sandwich" between the antibody on the gold and that on the latex. The coupling of gold and latex in turn causes a broadening of the LH and FSH side-scatter peaks, the magnitudeof which is dependent on the concentration of the corresponding analyte.

Using this method for simultaneous measurement of LH and FSH, we obtained the following correlations with the Abbott IMx methods. For LH, Copalis = 0.16 + 0.83 (IMx); r = 0.95; and n = 64. For FSH, Copalis = 0.196 + 0.98 (IMx); r = 0.98; and n = 36.


additional features

Utilizing the forward- and side-scatter detection parameters, Copalis instrumentation is capable of differentiating and enumerating various cell populations and thus could function as a hematology analyzer, as well as an immunoassay analyzer. In addition, using electronic gating to mask the scattering signal from blood cells, Copalis II should have the capability of performing immunoassay analysis on whole-blood specimens.


conclusions

Copalis is a versatile technology that may be applied to many areas of immunoassay, including infectious disease, autoimmunity, and endocrinology. A key feature of this technology is the ability to measure multiple analytes in the same reaction. This has now been demonstrated with multiplex assays for ToRC (toxoplasmosis, rubella, and cytomegalovirus), EBV (Epstein-Barr nuclear antigen, viral capsid antigen, and early antigen), syphilis (treponemal and nontreponemal antigen), autoimmunity (SSA and SSB), and fertility (LH and FSH). Several other technologies for multianalyte detection have been proposed (5) . For example, Fulton et al. ((6)) report a system that also utilizes latex particles as solid phase, with fluorometric detection on a flow cytometer. Advantages of Copalis over these other techniques include the homogeneous format (no washing steps) and detection by light scattering. These features allow Copalis instrumentation to be relatively simple and inexpensive.


Footnotes

DiaSorin USA, 1990 Industrial Blvd., Stillwater, MN 55082

fax 612-773-1519, e-mail John.Kamerud{at}Incstar.com


References

  1. Bodner AJ, Britz JA. Copalis technology. Chan DW eds. Immunoassay automation: an updated guide to systems 1996:253-275 Academic Press New York. .
  2. Benecky MJ, Post DR, Schmitt SM, Kochar MS. Detection of hepatitis B surface antigen in whole blood by coupled particle light scattering (Copalis). Clin Chem 1997;43:1764-1770. [Abstract/Free Full Text]
  3. Larsen SA, Hunter EF, Kraus SJ, eds. A manual of tests for syphilis. Washington, DC: American Public Health Association, 1990:191pp..
  4. Tan EM. Autoantibodies to nuclear antigens (ANA): their immunobiology and medicine. Advances in immunology (Advances in immunology, Vol. 33) 1982:167-240 Academic Press New York. .
  5. Kakabakos SE, Christopoulos TK, Diamandis EP. Multianalyte immunoassay based on spatially distinct fluorescent areas quantified by laser-excited solid-phase time-resolved fluorometry. Clin Chem 1992;38:338-342. [Abstract/Free Full Text]
  6. Fulton RJ, McDade RL, Smith PL, Kienker LJ, Kettman JR. Advanced multiplex analysis with the FlowMetrix system. Clin Chem 1997;43:1749-1756. [Abstract/Free Full Text]



The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
S. Faucher, A. Martel, A. Sherring, T. Ding, L. Malloch, J. E. Kim, M. Bergeron, P. Sandstrom, and F. F. Mandy
Protein Bead Array for the Detection of HIV-1 Antibodies from Fresh Plasma and Dried-Blood-Spot Specimens
Clin. Chem., July 1, 2004; 50(7): 1250 - 1253.
[Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (12)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Benecky, M. J.
Right arrow Articles by Kamerud, J. Q.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Benecky, M. J.
Right arrow Articles by Kamerud, J. Q.
Related Collections
Right arrow Oak Ridge Conference


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS