Clinical Chemistry Siemens Point of Care - Urinalysis
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 44: 2054-2056, 1998;
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (28)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Smith, P. L.
Right arrow Articles by DuBois, D. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smith, P. L.
Right arrow Articles by DuBois, D. B.
Related Collections
Right arrow Oak Ridge Conference
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 1998;44:2054-2056.)
© 1998 American Association for Clinical Chemistry, Inc.


Poster Sessions

A Rapid, Sensitive, Multiplexed Assay for Detection of Viral Nucleic Acids Using the FlowMetrix System

Perry L. Smith1,a, Cindy R. WalkerPeach2, R. Jerrold Fulton1, and Dwight B. DuBois2

1 Luminex Corporation, 12212 Technology Blvd., Austin, TX 78727 and
2 Cenetron Diagnostics, 2170 Woodward St., Austin, TX 78744;
a address correspondence to this author at: Luminex Corporation, 1638 Osprey Dr., DeSoto, TX 75115

Sensitive assays for viral nucleic acids are important tools for the accurate diagnosis and treatment of viral diseases. Unlike serological methods, viral load analysis provides quantitative information about viral replication. Studies have shown that viral load is a powerful predictor of disease progression in both human immunodeficiency virus (HIV) and hepatitis C virus (HCV) infections (1)(2) . Additionally, monitoring viral load is a proven method for assessing the effects of antiviral treatments for both HIV and HCV infections (3)(4)(5)(6) .

Recently, the need for simultaneous viral load determinations of different viruses within a single individual has been established. Numerous studies indicate synergistic effects of co-infection with multiple viruses. For example, higher HCV titers have been reported in individuals co-infected with HIV (7) . Likewise, herpes simplex virus (HSV) infections can be particularly severe in individuals with HIV-compromised immune systems (8) .

This report describes a novel method for the detection and quantitation of viral nucleic acids in a rapid, multiplexed format. This method is based on fluorescent detection using the FlowMetrix analysis system. The FlowMetrix system is a computer-enhanced flow cytometer that uses microspheres dyed with multiple fluorescent colors (9) . The microspheres are 5.5 µm in diameter and are composed of polystyrene and methacrylate to provide a surface carboxylate functionality. During manufacturing, two fluorophores (red and orange) are combined within the microspheres in a unique ratio. Currently, there are 64 different ratios of red and orange fluorescence, which identify 64 distinctly colored sets of microspheres. Differently colored microsphere sets can be individually coupled via the surface carboxylate moiety to a specific oligonucleotide probe for a unique nucleic acid sequence. Once individually coupled, the microsphere sets can be mixed, and the mixture can be used to probe complex solutions containing multiple sequences in a single hybridization.

In the current study, capture oligonucleotide probes specific for HIV, HCV, HSV, and their respective internal amplification control sequences were synthesized with a 5' amino substitution and a 15-atom spacer between the reactive group and the hybridizing length (Oligo's Etc.) (9)(10)(11)(12) . The six 5'-amino-substituted oligonucleotides were coupled individually to six differently colored microsphere sets using a carbodiimide (EDC) coupling method (9) . After coupling, the six microsphere sets were mixed to form a multiplexed set.

HIV, HCV, and HSV nucleic acid sequences were amplified as described previously (10)(11)(12) and included a 5' biotinylated primer in each case. For each viral amplification, a unique internal amplification control was also added. Control templates were engineered such that both viral and control sequences were amplified by the same primer set (10)(11)(12) . After PCR amplification, the PCR products were denatured at 100 °C for 10 min. The denatured PCR products were added to an equal volume of 2x hybridization buffer containing 8000 of each of the six microsphere subsets (1x hybridization buffer contained 2.25 mol/L tetramethyl ammonium chloride, 0.75 g/L sodium dodecyl sulfate, 37.5 mmol/L Tris, pH 8.0, and 1.5 mmol/L EDTA, pH 8.0). This mixture was hybridized at 37 °C for 1 h. After hybridization, 2 µL of a 10-g/L solution of Alexa-488® (green fluorescence)-Streptavidin (Molecular Probes) was added. Samples were incubated at room temperature for another 30 min, then diluted with 200 µL of 1x hybridization buffer, and analyzed with the FlowMetrix system.

The FlowMetrix system consists of a Beckton Dickinson FACScan flow cytometer configured with proprietary hardware and software that controls all functions of the cytometer as well as providing real-time data acquisition and analysis for the multiplexed assay. During the analysis on the cytometer, the system categorizes each microsphere according to its red-orange fluorescent color set and determines the average green fluorescence for each set of microspheres, providing a quantification of that specific hybridized PCR product.

Results from the multiplexed assay are shown in Fig. 1 . To determine specificity, increasing amounts of each PCR product were individually hybridized to the entire multiplexed set of six oligonucleotide-coupled microspheres. All reactions were performed in duplicate, and the mean values were plotted on semilog plots. These results show that the hybridization of each PCR product to its complementary microsphere set was highly specific and quantitative over a dynamic range of up to 3 logs. Only at extremely high amounts of PCR product (>1010 copies) was there any detectable cross-hybridization. The internal amplification controls used in this study were designed to be used as calibrators by which the number of input viral template copies could be calculated. A known quantity of the control template was added to the test sample, and a single pair of primers was used to amplify both the viral and control sequences in a single PCR reaction. Under specific amplification conditions, the amount of control PCR product will be proportional to the amount of viral PCR product. The results presented here demonstrate the ability to quantitatively and specifically detect each PCR product in a multiplexed reaction. Preliminary work with clinical HIV samples suggests that multiplexed quantitation is possible.



View larger version (29K):
[in this window]
[in a new window]
 
Figure 1. Concentration response profile for hybridization of viral sequences (left) and controls (right).

Titration curves of serial dilutions of HIV ({blacktriangleup}), HIV-control ({bigtriangleup}), HSV ({bullet}), HSV-control ({circ}), HCV ({blacksquare}), and HCV-control ({square}) amplicons in a multiplexed assay are shown. All six microspheres are included in each reaction. As the concentration of each PCR product increases, there is a corresponding increase in the mean fluorescence intensity (green) of only the microspheres bearing the respective complementary capture probe.

In conclusion, these results indicate that the FlowMetrix assay system is rapid, sensitive, and specific. The system can be applied to the simultaneous detection of both RNA and DNA viruses, such as human immunodeficiency, hepatitis C, and herpes simplex viruses that are common in patients who are at risk for multiple infections. The flexibility of this system allows inclusion of new sequences, such as genetic variants or additional viruses, by simply adding appropriate microsphere sets to the multiplexed mixture.


Acknowledgments

This work was supported jointly by Luminex Corporation and Cenetron Diagnostics.


Footnotes

fax 972-224-9689, e-mail perrys{at}luminexcorp.com


References

  1. Mellors J, Rinaldo R, Gupta P, White R, Todd J, Kingsley L. Prognosis in HIV-1 infection predicted by the quantity of virus in plasma. Science 1996;272:1167-1170. [Abstract]
  2. Kato N, Yokosuka O, Hosoda K, Ito Y, Ohto M, Omata M. Quantification of hepatitis C virus by competitive reverse transcriptase polymerase chain reaction–increase of the virus in advanced liver disease. Hepatology 1993;18:16-20. [Web of Science][Medline] [Order article via Infotrieve]
  3. Schooley R. Correlation between viral load measurements and outcome in clinical trials of antiviral drugs. AIDS 1995;9(Suppl 2):S15-S19.
  4. Kappes J, Saag M, Shaw G, Hahn B, Chopra P, Chen S, Emini E, et al. Assessment of antiretroviral therapy by plasma viral load testing: standard and ICD HIV-1 p24 antigen and viral RNA (QC-PCR) assays compared. J Acquir Immune Defic Syndr Hum Retrovirol 1995;10:139-149. [Web of Science][Medline] [Order article via Infotrieve]
  5. Chayama K, Saitoh S, Arase Y, Ikeda K, Matsumoto T, Sakai Y, et al. Effect of interferon administration on serum hepatitis C virus RNA in patients with chronic hepatitis C. Hepatology 1991;13:1040-1043. [Web of Science][Medline] [Order article via Infotrieve]
  6. Di Bisceglie A, Shindo M, Fong T, Fried M, Swain M, Bergasa N, et al. A pilot study of ribavirin therapy for chronic hepatitis C. Hepatology 1992;16:649-654. [Web of Science][Medline] [Order article via Infotrieve]
  7. Sherman K, O'Brien J, Gutierrez A, Harrison S, Urdea M, Neuwald P, Wilber J. Quantitative evaluation of hepatitis C virus RNA in patients with concurrent human immunodeficiency virus infections. J Clin Microbiol 1993;31:2679-2682. [Abstract/Free Full Text]
  8. Stewart J, Reef S, Pellett P, Corey L, Whitley R. Herpesvirus infections in persons infected with human immunodeficiency virus. Clin Infect Dis 1995;21(Suppl 1):S114-S120.
  9. Fulton R, McDade R, Smith P, Kienker L, Kettman J. Advanced multiplexed analysis with the FlowMetrix system. Clin Chem 1997;43:1749-1756. [Abstract/Free Full Text]
  10. Kwok S, Sninsky J. PCR detection of human immunodeficiency virus type 1 proviral DNA sequences. Persing D Smith T Smith F Tenover T White T eds. Diagnostic molecular biology: principles and applications 1993:309-315 ASM Press Washington, DC. .
  11. Young K, Resnick R, Myers T. Detection of hepatitis C virus RNA by combined reverse transcription-polymerase chain reaction assay. J Clin Microbiol 1993;31:882-886. [Abstract/Free Full Text]
  12. Cone R, Hobson A, Huang W. Co-amplified positive control detects inhibition of polymerase chain reactions. J Clin Microbiol 1992;30:3185-3189. [Abstract/Free Full Text]



The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
S. C. Johnson, D. J. Marshall, G. Harms, C. M. Miller, C. B. Sherrill, E. L. Beaty, S. A. Lederer, E. B. Roesch, G. Madsen, G. L. Hoffman, et al.
Multiplexed Genetic Analysis Using an Expanded Genetic Alphabet
Clin. Chem., November 1, 2004; 50(11): 2019 - 2027.
[Abstract] [Full Text] [PDF]


Home page
Genome ResHome page
L. Yang, D. K. Tran, and X. Wang
BADGE, BeadsArray for the Detection of Gene Expression, a High-Throughput Diagnostic Bioassay
Genome Res., November 1, 2001; 11(11): 1888 - 1898.
[Abstract] [Full Text] [PDF]


Home page
Nucleic Acids ResHome page
Y. Zhang, B. D. Price, S. Tetradis, S. Chakrabarti, G. Maulik, and G. M. Makrigiorgos
Reproducible and inexpensive probe preparation for oligonucleotide arrays
Nucleic Acids Res., July 1, 2001; 29(13): e66 - e66.
[Abstract] [Full Text] [PDF]


Home page
Appl. Environ. Microbiol.Home page
A. Spiro, M. Lowe, and D. Brown
A Bead-Based Method for Multiplexed Identification and Quantitation of DNA Sequences Using Flow Cytometry
Appl. Envir. Microbiol., October 1, 2000; 66(10): 4258 - 4265.
[Abstract] [Full Text]


Home page
Clin. Chem.Home page
M. Brown and C. Wittwer
Flow Cytometry: Principles and Clinical Applications in Hematology
Clin. Chem., August 1, 2000; 46(8): 1221 - 1229.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Microbiol.Home page
J.-P. Defoort, M. Martin, B. Casano, S. Prato, C. Camilla, and V. Fert
Simultaneous Detection of Multiplex-Amplified Human Immunodeficiency Virus Type 1 RNA, Hepatitis C Virus RNA, and Hepatitis B Virus DNA Using a Flow Cytometer Microsphere-Based Hybridization Assay
J. Clin. Microbiol., March 1, 2000; 38(3): 1066 - 1071.
[Abstract] [Full Text]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (28)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Smith, P. L.
Right arrow Articles by DuBois, D. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smith, P. L.
Right arrow Articles by DuBois, D. B.
Related Collections
Right arrow Oak Ridge Conference
Right arrow Automation and Analytical Techniques


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS