Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 45: 1879-1880, 1999;
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lun, A.
Right arrow Articles by Sinha, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lun, A.
Right arrow Articles by Sinha, P.
Related Collections
Right arrow Laboratory Management
Right arrow General Clinical Chemistry
Right arrow Pediatric Clinical Chemistry
Right arrow Hematology
(Clinical Chemistry. 1999;45:1879-1880.)
© 1999 American Association for Clinical Chemistry, Inc.


Letters

Reference Values for Neonates and Children for the UF-100 Urine Flow Cytometer

Andreas Lun1, Reinhard Ziebig1, Hannes Hammer2, Uwe Otting1, Guido Filler2 and Pranav Sinha1,a

1 Institute for Laboratory Medicine, and Pathobiochemistry, and,
2 Department of Neonatology, and Pediatric Clinic, University Clinic Charité, Humboldt University Berlin, Schumannstrasse 21, 10117 Berlin, Germany
a Author for correspondence. Fax 4930-2802-8422; e-mail pranav.sinha{at}charite.de

The UF-100 fully automated urine flow cytometer classifies urinary particles on the basis of their light scattering, fluorescence, and impedance properties. The UF-100 counts erythrocytes, leukocytes, bacteria, epithelial cells, and casts. The operating principles of the UF-100 and its precision, accuracy, and analytical sensitivity have been published previously (1)(2)(3)(4). The high sensitivity of the flow cytometer leads to different reference values. In a recent report, Gyory et al. (5) presented reference values for children; for newborns, however, reference values have not as yet been published. In this report, we present preliminary reference values for neonates and children.

To establish these reference ranges, samples from two groups of children were analyzed. The pediatricians considered the infants in the first group to have no afflictions of the urinary tract after studying the case history, laboratory values (e.g., creatinine and urea), and the urine test strip results (n = 114). These infants were admitted to the neonatal clinic and remained there for >5 days. Admission automatically included urine examination in daily routine programs without additional consent of the parents. The long admission periods were attributable to other factors: maternal problems, such as cesarean section (n = 57); or neonatal problems, such as atresia of the esophagus (n = 3), inguinal hernia (n = 5), atrio-ventricular canal (n = 3), or preterm birth at more than 34 weeks of gestation without respiratory complications (n = 46). Urine was collected using perineal stick-on plastic containers that were inspected every hour.

Urine was also collected from preoperative children without evidence of hematuria, urinary tract infection (UTI), or renal disease (n = 141) as evaluated by the case history, laboratory values (e.g., creatinine and urea), and test strip results from the laboratory. In each case, a pediatrician was the person evaluating the child. The surgical procedures were adenotomy (n = 57), tonsillectomy (n = 54), otocleisis (n = 7), and correction of various forms of cheilognathouranoschisis (n = 23). Three children were excluded because of UTI from unknown causes in the case history.

Both groups that constituted the reference population were regarded as free of any afflictions of the kidney and the urinary tract. Both groups of samples were analyzed using the test strip analyzer Clinitek Atlas (Bayer Diagnostics) and the UF-100 urine flow cytometer (Sysmex). Results for flow cytometry were given in cells per microliter of urine. Pathological values were rechecked using not only the above mentioned analyzers but also in several cases by examination of the urinary sediment after centrifugation. This result was reported as cells/HPF (high-power field). The children were again clinically examined, and those with previously undetected UTIs or other diseases affecting the urogenital system were not included in the reference set. Because the values did not exhibit a gaussian distribution, the 5th and 95th percentiles were used as reference limits.

The provisional reference values for healthy neonates (n = 114) are shown in the upper portion of Table 1 . For comparison, the results for erythrocytes and leukocytes obtained after centrifugation and microscopic analysis of the urinary sediment (0–2 cells/HPF and 0–3 cells/HPF, respectively) are shown. The UF-100 measurements clearly gave higher cell counts for erythrocytes (~5 cells/µL) and leukocytes (~12 cells/µL). Epithelial cells were also counted by the UF-100, yielding a numerical value of ~4 cells/µL. When sediment microscopy was used, only the presence of epithelial cells was reported. Casts were not usually present. Practically all urine samples examined exhibited the presence of bacteria. Thus, a relatively high cell count (~83 cells/µL) was obtained. Preanalytical factors such as storage time before analysis certainly affect this result.


View this table:
[in this window]
[in a new window]
 
Table 1. Preliminary reference values for erythrocytes, leukocytes, casts, bacteria, and epithelial and small round cells, using the urine flow cytometer UF-1001 for neonates and young children.

The reference values obtained for children (n = 141) are also shown in the lower portion of Table 1Up . Slightly higher values for erythrocytes and leukocytes were obtained with the UF-100 (~ 4 cells/µL for both erythrocytes and leukocytes compared with 1 cell/HPF obtained with microscopy of the urinary sediment). Fewer epithelial cells and bacteria were seen in this population.

In both groups, however, the values for erythrocytes and leukocytes varied, with ranges of ~1–36 cells/µL and ~3–57 cells/µL, respectively, when the results between the 5th and 95th percentile were examined. These values are obviously higher than those obtained with microscopic examination of the urinary sediment. Thus, the results should be interpreted with care because the units obtained with the UF-100 (cells/µL) are obviously different from those obtained after centrifugation and microscopy of the urinary sediment (cells/HPF). This may be a problem at the beginning when clinicians are not used to the units of the UF-100. Our experience with certain wards, however, shows that clinicians will adjust to changes relatively quickly.

The small round cells (SRCs) most probably originated from the tubular epithelium of the kidney or the transitional epithelium of the urinary tract. Very small quantities of these cells were seen in urine samples from both groups. Thus, the presence of up to 5 SRC/µL in neonates and up to 2 SRC/µL in children are within the 95th percentile and are not regarded as pathological.

We hope that these values are helpful to those colleagues already using the UF-100 in routine urinalysis.


Acknowledgments

This work is dedicated to Professor Eckart Köttgen on his 60th birthday.


References

  1. Nakamoto H. Automated urinalysis. Sysmex J Int 1996;6:168-172.
  2. Muranaka K. Clinical use of the UF-100 for the diagnosis of urinary tract infection. Sysmex J Int 1996;6:46-50.
  3. Ben-Ezra J, Bork L, McPherson RA. Evaluation of the Sysmex UF-100 automated urinalysis analyzer. Clin Chem 1998;44:92-95. [Abstract/Free Full Text]
  4. Schubö W, Uehrlinger HM, Perleth C, Schröger E, Sierwald W. SPSS–Handbuch der Programmversionen 4. 0 und SPSS-X 3.0. Stuttgart, Germany: Gustav Fischer Verlag, 1991..
  5. Gyory AZ, Hawkins T, Ross M, McLennan J, Ibels L. Clinical value of urine microscopy by manual and automated methods. Lab Hematol 1999;4:211-216.
  6. Rick W. Klinische Chemie und Mikroskopie, 6th ed 1990:412-423 Springer Berlin. .
  7. Tietz NW. Clinical guide to laboratory tests, 3rd ed. Philadelphia, PA: WB Saunders, 1995:550pp..



The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
P. Froom, R. Etzion, and M. Barak
What Is an Abnormal Test Strip Urinary Erythrocyte Concentration?
Clin. Chem., March 1, 2004; 50(3): 673 - 675.
[Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lun, A.
Right arrow Articles by Sinha, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lun, A.
Right arrow Articles by Sinha, P.
Related Collections
Right arrow Laboratory Management
Right arrow General Clinical Chemistry
Right arrow Pediatric Clinical Chemistry
Right arrow Hematology


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS