Clinical Chemistry Siemens Point of Care - Urinalysis
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 46: 864-867, 2000;
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (13)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Frank, E. L.
Right arrow Articles by Roberts, W. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Frank, E. L.
Right arrow Articles by Roberts, W. L.
Related Collections
Right arrow Molecular Diagnostics and Genetics
Right arrow Proteomics and Protein Markers
Right arrow Hematology
Right arrow Endocrinology and Metabolism
(Clinical Chemistry. 2000;46:864-867.)
© 2000 American Association for Clinical Chemistry, Inc.


Technical Briefs

Effects of Hemoglobin C and S Traits on Seven Glycohemoglobin Methods

Elizabeth L. Frank1, Linda Moulton2, Randie R. Little3, Hsiao-Mei Wiedmeyer3, Curt Rohlfing3 and William L. Roberts1,a

1 University of Utah, Department of Pathology, Salt Lake City, UT 84108

2 ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT 84108

3 University of Missouri-Columbia School of Medicine, Departments of Child Health and Pathology, Columbia, MO 65212
a address correspondence to this author at: ARUP Laboratories, 500 Chipeta Way, Salt Lake City, UT 84108

Glycohemoglobin (gHb) is a marker of long-term glycemic control that has been shown to correlate with complications of diabetes mellitus (1). The National Glycohemoglobin Standardization Program (NGSP) was established to standardize gHb results so that clinical laboratory results are comparable to those reported by the Diabetes Control and Complications Trial (2)(3). Previous studies have shown that some gHb methods yield inaccurate results with samples heterozygous for hemoglobin (Hb) C or Hb S (4)(5)(6). At least 10% of black Americans have either Hb C or S trait, and there were 19 million black Americans over age 19 in 1990 (7)(8)(9)(10). The prevalence of diabetes is estimated to be 5.1% of the adult population, with the rate for non-Hispanic blacks being 1.6-fold higher than that of non-Hispanic whites (11). It is therefore probable that at least 150 000 Americans with diabetes have Hb C or S trait. Here, we investigate the measurement of gHb in specimens containing Hb C or S trait using eight gHb methods currently in clinical use.

Whole blood samples from individuals homozygous for Hb A (n = 43) and heterozygous for Hb C or S (n = 43 and 61, respectively) were collected in EDTA tubes. Hb variants were identified by their characteristic Variant A1c HPLC chromatograms (Bio-Rad Laboratories). Aliquots of these samples containing between 4% and 14% Hb A1c (NGSP Hb A1c evaluation range) were stored refrigerated (2–8 °C) and analyzed within 10 days of collection. This study was approved by the Institutional Review Board of the University of Utah.

The CLC 330 gHb analyzer (Primus Corporation) was operated at the University of Missouri. This method was chosen as the comparison method for this study because results from boronate affinity chromatography should not be influenced by the presence of Hb variants (12)(13)(14)(15). The following methods/instruments were evaluated: the A1c 2.2 PlusTM Glycohemoglobin Analyzer (Tosoh Medics), the DiamatTM Analyzer System and a VariantTM Hemoglobin Testing System (Bio-Rad Laboratories), the IMx® Glycated Hemoglobin assay (Abbott Laboratories), Diatrac/Paragon® Electrophoresis System (Beckman Instruments), Tinaquant II on an Hitachi 717 analyzer (Roche Diagnostics), and the DCA 2000 Analyzer (Bayer Corporation, Elkhart, IN).

To eliminate suspected carryover when samples containing Hb C trait were analyzed by the A1c 2.2 Plus method, three samples homozygous for Hb A were analyzed but not reported after each sample containing Hb C trait. Diamat and CLC 330 HPLC analyses were performed in NGSP Network Laboratories. In these laboratories, in-house calibrator materials and assigned values were used. For all other methods, samples were analyzed according to the manufacturers’ instructions. For samples containing Hb AC, the Diamat 10-min extended program was used. A subset of samples with Hb AS (n = 10) was analyzed by Diamat HPLC using two different column series (P and R); all other samples were analyzed using a P-series column.

For each test method, results for each group of samples (Hb AA, Hb AC, and Hb AS) were compared with results from the comparison method (CLC 330). An overall test for coincidence of two least-squares linear regression lines was performed using SAS software (SAS Institute) to determine whether the presence of Hb C or S trait caused a statistically significant difference (P <0.01) in results relative to the comparison method. The presence of Hb C produced statistically significant differences for all methods tested except the A1c 2.2 Plus (P = 0.014) and the Variant A1c (P = 0.411). The presence of Hb S trait produced statistically significant differences for all methods except the IMx (P = 0.072).

Deming regression analysis was performed using EP Evaluator, release 3, software (David G. Rhoads, Kennett Square, PA) to determine whether the presence of Hb C and S traits produced clinically significant effects. Given the Diabetes Control and Complications Trial Reference Method upper limit of normal of 6%, and the American Diabetes Association goal and action limits of 7% and 8%, respectively, Hb A1c concentrations of 6% and 9% were chosen as important evaluation limits. Given the need to clearly distinguish the difference among 6%, 7%, and 8% Hb A1c, a >10% deviation (0.6% at 6% Hb A1c and 0.9% at 9% Hb A1c) compared with the Hb AA sample group was used to define a clinically significant difference. No clinically significant interference attributable to Hb AC or Hb AS was seen with the A1c 2.2 Plus, DCA 2000, and Tina-quant II methods (Table 1 ). The Diamat and Variant A1c methods showed clinically significant interference from Hb AS but not from Hb AC. Both Hb AC and Hb AS produced clinically significant interferences for the Diatrac and IMx methods, although the difference observed with Hb S with the IMx method was not statistically significant. Box plots for each group of samples and for each method are shown in Fig. 1 . Of note is the increased scatter observed for the A1c 2.2 Plus, Diatrac, and Variant A1c methods for samples containing Hb C or S trait compared with Hb AA samples.


View this table:
[in this window]
[in a new window]
 
Table 1. Average differences from the comparison method for samples containing either Hb C or S traits.1



View larger version (17K):
[in this window]
[in a new window]
 
Figure 1. Box plots summarizing the absolute differences between each test method and the comparison method for each Hb type.

The horizontal line within each box is the median difference between the test and comparison methods. The upper and lower limits of each box correspond to the 25th and 75th percentile of the differences. The highest and lowest whiskers represent the minimal and maximal differences between test and comparison methods. AA, Hb AA trait; AC, Hb AC trait; AS, Hb AS trait. * indicates differences from Hb AA that are both statistically and clinically significant.

Our data for Hb AS samples with the Diamat method were not consistent with previous results (5)(6). One difference between the current study and these two previous reports was that an 8-min program was used in the current study, whereas a 5-min program was used previously. Another potential difference was the series of column and reagents used. This information was not provided for either of the previous studies. The R series replaced the P series in March 1999; this series contained a new lot of packing material, which provided improved peak resolution. To determine whether differences between these two series could also contribute to variability with Hb variants, a subset of samples containing Hb AS was analyzed using two different Diamat column series. The P-series column gave higher results with Hb AS, which was more pronounced in the lower Hb A1c range (slope = 0.89; intercept = 2.16); R-series column results with Hb AS, on the other hand, were lower at higher Hb A1c concentrations (slope = 0.74; intercept = 1.77).

One explanation for the overestimated Hb A1c results observed for Hb S trait with the Diamat P column and Variant A1c methods and the underestimated results observed with the Diamat R column may be that Hb A0 and Hb S0 are not well resolved from each other. This could lead to underestimation of Hb A0 and consequent overestimation of the percentage of Hb A1c or vice versa. Overestimation of Hb A1c is most apparent at concentrations <8%. Clinically, this may lead to overly rigorous glycemic control with a consequent increase in hypoglycemic episodes. This hypothesis requires formal testing in a clinical outcome study.

In Hb C, lysine is substituted for glutamic acid at position 6 in the ß chain; in Hb S valine is substituted at the same position (4). In immunoassay methods, these amino acid substitutions at position 6 may alter the shape of the protein sufficiently to change its binding characteristics with the reagent antibody (15). This may explain the small positive bias in the DCA 2000 assay and small negative bias in the Tina-quant II assay. The DCA 2000 was previously reported to give falsely increased results for Hb AC (5)(6). However, the Diamat, not a boronate affinity method, was used as the comparison method.

The only electrophoretic method evaluated in this study was the Diatrac system. Significant underestimation of the percentage of Hb A1c was observed for samples containing either Hb C or S trait, with samples containing Hb S trait being the most affected. In this system, Hb A1c is resolved from Hb C1c and Hb S1c (Hb C and Hb S glycated at the NH2 terminus of the Hb ß chain), but Hb A0 is not resolved from Hb C0 and Hb S0. This leads to an underestimation of the percentage of Hb A1c that is proportional to the amount of Hb C0 or Hb S0 present in the sample. Samples containing Hb AC or Hb AS should not be analyzed by this method.

The IMx method uses a boronate affinity reagent coupled with an ion-capture reagent to measure total gHb. One possible explanation for the overestimation of Hb A1c is that charge interactions between the lysine residue at position 6 of the Hb C ß chain and the polyanion reagent might lead to capture of nonglycated Hb by the polycation capture matrix with consequent overestimation of gHb.

In conclusion, the presence of Hb C or S trait can produce clinically significant differences in gHb results for some methods. These differences may, in some cases, be dependent on the lot of reagents used. More careful attention to the effects of Hb variants on the results of gHb methods is necessary to ensure accurate results for the >150 000 Americans who have a Hb variant and diabetes mellitus. In addition, more detailed information about the effects of common Hb variants, including Hb C and S trait, should be included in the package insert of each commercially available gHb method.


Acknowledgments

A DCA 2000 instrument and reagents were provided by Bayer Diagnostics. Tina-quant II reagents were provided by Roche Diagnostics. IMx reagents were provided by Abbott Diagnostics. Beckman Coulter provided all results for the Diatrac method. This work was supported in part by the ARUP Institute for Clinical and Experimental Pathology. We thank Dr. Tom Lohmann (Ochsner Foundation Hospital, New Orleans, LA) and Marilyn Carpenter (University of Mississippi Medical Center, Jackson, MS) for providing samples containing Hb C and S trait, and Drs. Kory Ward-Cook and Jim Noffsinger for critical review of this manuscript.


Footnotes

fax 801-584-5207, e-mail william.roberts{at}arup-lab.com


References

  1. Edelman SV. Importance of glucose control. Med Clin N Am 1998;82:665-687. [Web of Science][Medline] [Order article via Infotrieve]
  2. . National Glycohemoglobin Standardization Program Steering Committee. Implementation of the National Glycohemoglobin Standardization Program (NGSP) [Abstract]. Diabetes 1997;46(Suppl 1):151A.
  3. National Glycohemoglobin Standardization Program. The new bias criteria. http://web.missouri.edu/~diabetes/ngsp/indexnc.html (accessed August 1999)..
  4. Weykamp CW, Penders TJ, Muskiet FAJ, van der Slik W. Influence of hemoglobin variants and derivatives on glycohemoglobin determinations, as investigated by 102 laboratories using 16 methods. Clin Chem 1993;39:1717-1723. [Abstract]
  5. Roberts WL, McCraw M, Cook CB. Effect of sickle trait and hemoglobin C trait on determinations of hemoglobin A1c by an immunoassay method. Diabetes Care 1998;21:983-986. [Abstract]
  6. Roberts WL, Chiasera JM, Ward-Cook KM. Glycohemoglobin results in samples with hemoglobin C or S trait: a comparison of four test systems. Clin Chem 1999;45:906-909. [Free Full Text]
  7. Eckman JR. The Sickle Cell Foundation of Georgia, Inc. The Sickle Cell Information Center. http://www.emory.edu/PEDS/SICKLE/hemoglb.htm (accessed May 1999)..
  8. National Heart, Lung, and Blood Institute. Management and therapy of sickle cell disease. Sickle cell trait. http://www.nhlbi.nih.gov/health/prof/blood/sickle/sickle.txt (accessed August 1999)..
  9. Meyer LM, Adams JG, III, Steinberg MH, Miller IE, Stokes N. Screening for sickle cell trait: the Veterans Administration National Sickle Cell Program. Am J Hematol 1987;24:429-432. [Web of Science][Medline] [Order article via Infotrieve]
  10. US Department of Commerce, Economics and Statistics Administration, Bureau of the Census. We the Americans: Blacks. http://www.census.gov/apsd/wepeople/we-1.pdf (accessed February 2000)..
  11. Harris MI, Flegal KM, Cowie CC, Eberhardt MS, Goldstein DE, Little RR, et al. Prevalence of diabetes, impaired fasting glucose, and impaired glucose tolerance in U.S. adults. The third National Health and Nutrition Examination Survey, 1988–1994. Diabetes Care 1998;21:518-524. [Abstract]
  12. Abraham EC. Glycosylated hemoglobins 1985:91-171 Marcel Dekker New York. .
  13. Fluckiger R. Glycated hemoglobins [Review]. J Chromatogr 1988;429:279-292. [Web of Science][Medline] [Order article via Infotrieve]
  14. Nuttall FQ. Comparison of percent total gHb with percent HbA1c in people with and without known diabetes. Diabetes Care 1998;21:1475-1480. [Abstract]
  15. Holownia P, Bishop E, Newman DJ, John WG, Price CP. Adaptation of latex-enhanced assay for percent glycohemoglobin to a Dade Dimension® analyzer. Clin Chem 1997;43:76-84. [Abstract/Free Full Text]



The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
R. R. Little, C. L. Rohlfing, S. Hanson, S. Connolly, T. Higgins, C. W. Weykamp, M. D'Costa, V. Luzzi, W. E. Owen, and W. L. Roberts
Effects of Hemoglobin (Hb) E and HbD Traits on Measurements of Glycated Hb (HbA1c) by 23 Methods
Clin. Chem., August 1, 2008; 54(8): 1277 - 1282.
[Abstract] [Full Text] [PDF]


Home page
Annals of Clinical & Laboratory ScienceHome page
J. M. Abadie and A. A. Koelsch
Performance of the Roche Second Generation Hemoglobin A1c Immunoassay in the Presence of Hb-S or Hb-C Traits
Ann. Clin. Lab. Sci., January 1, 2008; 38(1): 31 - 36.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
W. L. Roberts, S. Safar-Pour, B. K. De, C. L. Rohlfing, C. W. Weykamp, and R. R. Little
Effects of Hemoglobin C and S Traits on Glycohemoglobin Measurements by Eleven Methods
Clin. Chem., April 1, 2005; 51(4): 776 - 778.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
R. R. Little, H. Vesper, C. L. Rohlfing, M. Ospina, S. Safar-Pour, and W. L. Roberts
Validation by a Mass Spectrometric Reference Method of Use of Boronate Affinity Chromatography to Measure Glycohemoglobin in the Presence of Hemoglobin S and C Traits
Clin. Chem., January 1, 2005; 51(1): 264 - 265.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
W. L. Roberts, B. K. De, D. Brown, C. M. Hanbury, J. D. Hoyer, W. G. John, T. L. Lambert, R. B. Lundell, C. Rohlfing, and R. R. Little
Effects of Hemoglobin C and S Traits on Eight Glycohemoglobin Methods
Clin. Chem., February 1, 2002; 48(2): 383 - 385.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
L. Bry, P. C. Chen, and D. B. Sacks
Effects of Hemoglobin Variants and Chemically Modified Derivatives on Assays for Glycohemoglobin
Clin. Chem., February 1, 2001; 47(2): 153 - 163.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (13)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Frank, E. L.
Right arrow Articles by Roberts, W. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Frank, E. L.
Right arrow Articles by Roberts, W. L.
Related Collections
Right arrow Molecular Diagnostics and Genetics
Right arrow Proteomics and Protein Markers
Right arrow Hematology
Right arrow Endocrinology and Metabolism


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS