Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 47: 1918-1921, 2001;
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wishart, D. S.
Right arrow Articles by Newton, J. B.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Wishart, D. S.
Right arrow Articles by Newton, J. B.
Related Collections
Right arrow Molecular Diagnostics and Genetics
Right arrow Pediatric Clinical Chemistry
Right arrow Nutrition
Right arrow Oak Ridge Conference
Right arrow Drug Monitoring and Toxicology
Right arrow Endocrinology and Metabolism
(Clinical Chemistry. 2001;47:1918-1921.)
© 2001 American Association for Clinical Chemistry, Inc.


Abstracts of Oak Ridge Posters

Magnetic Resonance Diagnostics: A New Technology for High-Throughput Clinical Diagnostics

David S. Wishart1, Lori M.M. Querengesser2a, Brent A. Lefebvre2, Noah A. Epstein2, Russ Greiner3 and Jack B. Newton2

1 2123 Dentistry/Pharmacy Center, Faculty of Pharmacy and Pharmaceutical Sciences, University of Alberta, Edmonton, Alberta, T6G 2N8 Canada;
2 Chenomx Inc., 2007, 8308-114 Street, Edmonton, Alberta, T6G 2E1 Canada;
3 122 Athabasca Hall, Artificial Intelligence Group, Department of Computing Science, University of Alberta, Edmonton, Alberta, T6G 2E8 Canada

aauthor for correspondence: fax 780-432-3388, e-mail lquerengesser{at}chenomx.com

Magnetic resonance diagnostics (MRD) uses automated, high-throughput nuclear magnetic resonance (NMR) spectroscopy for the rapid identification and quantification of small-molecule metabolites in biofluid mixtures (blood, urine, saliva, cerebrospinal fluid, and others). Specifically, MRD involves using a high-field (400 MHz) NMR instrument equipped with a small-volume flow probe and robotic sample handler to rapidly load biofluid samples and to collect their 1H NMR spectra. Spectral deconvolution software automatically assigns individual peaks to particular compounds and calculates concentrations from peak areas. MRD uses the principle of chemical shift separation to physically separate and identify individual compounds directly from 1H NMR spectra, thus avoiding chromatographic separation steps (e.g., HPLC, gas chromatography, and capillary electrophoresis). MRD is useful for rapid (<2 min per sample) qualitative and quantitative assessment of small-molecule metabolites.

NMR spectroscopy is not new to the field of clinical chemistry. Indeed several important applications have already been demonstrated in the area of diagnosis and therapeutic monitoring of metabolic disorders (1)(2)(3)(4), in toxicologic and renal testing (5)(6), and in the profiling of blood lipoproteins and cholesterol (7). An emerging approach to enable high-throughput in vivo toxicology is called metabonomics, which uses high-resolution NMR to rapidly evaluate the metabolic status of an animal (8)(9).

A key limitation to all of these NMR approaches is that they depend on manual sample handling and/or manual (i.e., expert) spectral analysis. This has made most NMR approaches to clinical analyses far too slow or too costly for routine chemical profiling or high-throughput screening. Because MRD is fully automated (sample handling, spectral collection, and spectral analysis are all handled by robots or computers), this technique offers the potential for high-throughput, comprehensive, and inexpensive chemical analysis of a wide range of biofluid samples.

To demonstrate the potential of MRD for high-throughput clinical screening and metabolic profiling, we constructed a simulated test-run of 1000 urine samples processed by a prototype MRD instrument developed jointly by our laboratory and Varian Inc. (Palo Alto, CA). Our intent was to investigate the performance of the MRD instrument and software under the demands of a high-throughput clinical testing laboratory. The instrument was assessed on sample-processing speed, robustness of sample handling, and accuracy of identifying samples and compounds.

We followed protocols and conditions approved by the University of Alberta’s Health Research Ethics Board to collect 1000 anonymous urine samples. A total of 925 samples were obtained from healthy adult volunteers who had completed consent forms. Seventy-five samples (63 children, 12 adults) were obtained as anonymous "discards" from several hospitals and clinics across Canada and were from patients with a wide variety of inborn errors of metabolism, neuroblastoma, and alcohol poisoning. All of the abnormal samples used in this test had been identified previously as such through conventional clinical screens. Among the abnormal samples were the following: 14 with propionic acidemia; 11 with methylmalonic aciduria; 11 with cystinuria; 6 with alkaptonuria; 4 with glutaric aciduria I; 3 each with pyruvate decarboxylase deficiency, ketosis, Hartnup disorder, cystinosis, neuroblastoma, phenylketonuria, ethanol toxicity, glycerol kinase deficiency, and hydroxymethylglutaryl-CoA-lyase deficiency; and 2 with carbamoylphosphate synthetase deficiency.

For MRD analysis, 990-µL portions from each urine sample were transferred to 1.8-mL autosampler vials, to which 0.5 mmol/L (10 µL of a 50 mmol/L solution) 3-(trimethylsilyl)-1-propane-sulfonic acid, sodium salt (Sigma-Aldrich) was added. We manually adjusted the samples to pH 6.5 using HCl(aq) or NaOH(aq), as necessary. Manual pH adjustment was necessary because the software module required to automatically measure the pH and adjust the spectral deconvolution process was not completed in time for this study.

The prototype MRD instrument consisted of a 400 MHz Varian NMR spectrometer equipped with a 60-µL triple resonance-flow probe with an interchangeable flow cell and a modified Varian VAST (Versatile Automatic Sample Transport) system. The VAST system uses a robotic liquid handler (Gilson Model 215) and three computer-controlled switching valves, which direct sample flow to and from the flow probe through small-diameter Teflon tubing. Each urine sample (250 µL) was automatically loaded into the NMR spectrometer and a one-dimensional 1H NMR spectrum collected (12 scans, 1.998 s; acquisition time, 0.5 s; acquisition delay, 6000 Hz sweepwidth) at ambient temperature (21.5 °C ± 0.5 °C). After data collection, the urine sample was ejected and the flow probe extensively rinsed with distilled water before the next sample was loaded. Sample carryover was <1%.

NMR spectra were autoprocessed (e.g., transformed, phased, and referenced) and deconvolved with a suite of specially developed software applications and databases. The deconvolution process allows for the automated identification and quantification of components in biofluid mixtures through spectral database comparisons. We tested for 149 compounds currently contained in our spectral database.

The instrument automatically loaded and analyzed all 1000 samples in 35.2 h (1 sample every 2.1 min) with minimal human supervision. The mean sample loading and rinsing time was 93 s, whereas spectral acquisition had a mean of 32 s. The mean times for spectral processing and deconvolution (which can be performed in parallel with sample loading and data acquisition) were 7.1 and 72 s, respectively. During the test run, one sample-loading failure occurred, but did not lead to instrument downtime.

The deconvolution software was tested for accuracy for the following: (a) identification and quantification of urinary metabolites, (b) identification of nonpathologic and abnormal urine samples, and (c) identification of specific disease states or conditions. We evaluated compound-identification and/or -quantification accuracy primarily through detailed analysis of the abnormal samples. Specifically, the 15 disorders found in the abnormal urine samples were characterized by 34 unique or abnormally abundant metabolites (e.g., homogentisic acid, glycerol, glutaric acid, and others). Our results indicate that the MRD software succeeded in correctly identifying all 34 abnormal metabolites in all 75 abnormal samples. All 34 metabolites had been identified previously through conventional HPLC, gas chromatography–mass spectrometry, or amino acid or organic acid analysis. In some cases, these metabolites were also detected in nonpathologic urine samples, but at concentrations too low to be of significance or at concentrations well within the reference interval (10).

Although it was not possible to verify the MRD-measured concentrations for all metabolites (most conventional tests provide only qualitative results), our results for those metabolites that could be reliably quantified indicated a correlation coefficient between conventionally measured concentrations and MRD-measured concentrations of 0.99 (spanning a concentration range of 400 µmol/L to 550 mmol/L). An example of compound identification and quantification achieved by this MRD software is shown in Fig. 1 , which shows an abnormal urine NMR spectrum (specifically, methylmalonic aciduria), along with the MRD-calculated NMR spectrum. The calculated spectrum was generated from individual NMR spectra of MRD-identified and -quantified compounds.



View larger version (18K):
[in this window]
[in a new window]
 
Figure 1. NMR spectrum compared with software-generated spectrum.

(A), 1H NMR spectrum of a urine sample from a patient with methylmalonic aciduria. (B), calculated NMR spectrum derived from summing the individual spectra of the compounds and concentrations determined by the MRD software. (Inset), an enlargement of the region between 1.9 and 4.1 ppm. Peak labels are as follows: (i), urea; (ii), 2-methyl malonate; (iii), 2,2-dimethyl-2-silapentanesulfonic acid; (iv), creatinine.

Among nonpathologic urine samples, 87 ± 11 compounds were routinely identified and quantified by the MRD software on average. The identification and concentration of these metabolites were partially verified through manual spectral analysis of three randomly chosen samples and their subsequent chemical analysis. It was not practical to attempt to verify the identity of all compounds in the nonpathologic urine samples via conventional assays. The MRD software failed to consistently identify citrate, glycine, and histidine, probably because of the extreme sensitivity of their chemical shifts to pH and/or calcium ion concentrations.

A simple concentration-threshold algorithm achieved 96% sensitivity and 100% specificity, with 72 of 75 abnormal samples being detected and all 925 nonpathologic samples being correctly classified as nonpathologic. The three missed abnormal samples were cystinuria, glutaric aciduria, and carbamoylphosphate synthetase deficiency. This misclassification arose from the fact that these three samples exhibited relatively modest concentrations of abnormal metabolites. This particular algorithm compared MRD-quantified metabolite data with those values reported by Tietz (10), a database of "normal" and "abnormal" metabolite concentrations (both absolute and relative to creatinine) tabulated from several literature sources, as well as metabolite data collected from our own assays. Age- and gender-related adjustments were not included in the classification scheme.

Tests of the disease classification accuracy (for 1 healthy state and 15 diseases or conditions) yielded 95.5% and 92.4% for sensitivity and specificity, respectively. Interestingly, all false positives were confined to those urine samples already classified as abnormal. In particular, four false positives were identified for propionic aciduria, three false positives for phenylketonuria, two false positives were identified for cystinuria, and one false positive for ethanol toxicity. These classification problems likely arose from the age-independent, all-or-none classification scheme used by our algorithm. A probabilistic assessment that included age- or gender-related values would likely have improved the results or revealed multiple disease possibilities.

Overall, this prototype instrument was rapid, robust, and accurate. It rapidly identified and quantified key metabolic markers of both common conditions (ethanol toxicity) and rare disorders (neuroblastoma). It appears to offer a high-throughput, inexpensive approach to metabolic profiling, with possible applications in medical diagnostics, drug compliance testing, toxicology, and food testing.


Acknowledgments

We wish to thank the University of Alberta Hospital, Toronto Hospital for Sick Children, Children’s & Women’s Health Centre of British Columbia, and Health Sciences Centre (Winnipeg, Manitoba) for contributing samples for this study. We also thank Dr. Fiona Bamforth (Department of Laboratory Medicine and Pathology, University of Alberta) for invaluable advice.


References

  1. Lindon JC, Nicholson JK, Everett JR. NMR Spectroscopy of Biofluids. Annu Rep NMR Spectrosc 1999;38:1-88.
  2. Wevers RA, Engelke UFH, Moolenaar SH, Brautigam C, De Jong JGN, Duran R, et al. 1H-NMR spectroscopy of body fluids: inborn errors of purine and pyrimidine metabolism. Clin Chem 1999;45:539-548.[Abstract/Free Full Text]
  3. Bamforth FJ, Dorian V, Vallance H, Wishart DS. Diagnosis of inborn errors of metabolism using 1H NMR spectroscopic analysis of urine. J Inherit Metab Dis 1999;22:297-301.[Medline] [Order article via Infotrieve]
  4. Burns SP, Woolf DA, Leonard JV, Iles RA. Investigation of urea cycle enzyme disorders by 1H-NMR spectroscopy. Clin Chim Acta 1992;209:47-60.[ISI][Medline] [Order article via Infotrieve]
  5. Komoroski E M, Komoroski RA, Valentine JL, Pearce JM, Kearns GL. The use of nuclear magnetic resonance spectroscopy in the detection of drug intoxication. J Anal Toxicol 2000;24:180-187.[Medline] [Order article via Infotrieve]
  6. Foxall PJD, Mellotte GJ, Bending MR, Lindon JC, Nicholson JK. NMR spectroscopy as a novel approach to the monitoring of renal transplant function. Kidney Int 1993;43:234-245.[ISI][Medline] [Order article via Infotrieve]
  7. Freedman DS, Otvos JD, Jeyarajah EJ, Barboriak JJ, Anderson AJ, Walker JA. Relation of lipoprotein subclasses as measured by proton nuclear magnetic resonance spectroscopy to coronary artery disease. Arterioscler Thromb Vasc Biol 1998;18:1046-1053.[Abstract/Free Full Text]
  8. Nicholson JK, Lindon JC, Holmes E. ’Metabonomics’: understanding the metabolic responses of living systems to pathophysiological stimuli via multivariate statistical analysis of biological NMR spectroscopic data. Xenobiotica 1999;29:1181-1189.[ISI][Medline] [Order article via Infotrieve]
  9. Robertson DG, Reily MD, Sigler RE, Wells DF, Paterson DA, Braden TK. Metabonomics: evaluation of nuclear magnetic resonance (NMR) and pattern recognition technology for rapid in vivo screening of liver and kidney toxicants. Toxicol Sci 2000;57:326-337.[Abstract/Free Full Text]
  10. Tietz NW eds. Clinical guide to laboratory tests, 3rd ed 1995:1-760 WB Sanders Press Philadelphia. .



The following articles in journals at HighWire Press have cited this article:


Home page
Brief BioinformHome page
D. S. Wishart
Current Progress in computational metabolomics
Brief Bioinform, September 1, 2007; 8(5): 279 - 293.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wishart, D. S.
Right arrow Articles by Newton, J. B.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Wishart, D. S.
Right arrow Articles by Newton, J. B.
Related Collections
Right arrow Molecular Diagnostics and Genetics
Right arrow Pediatric Clinical Chemistry
Right arrow Nutrition
Right arrow Oak Ridge Conference
Right arrow Drug Monitoring and Toxicology
Right arrow Endocrinology and Metabolism


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS