Clinical Chemistry 47: 2148-2150, 2001;
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Piffanelli, A.
Right arrow Articles by Pelizzola, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Piffanelli, A.
Right arrow Articles by Pelizzola, D.
Related Collections
Right arrow Laboratory Management
Right arrow Endocrinology and Metabolism
(Clinical Chemistry. 2001;47:2148-2150.)
© 2001 American Association for Clinical Chemistry, Inc.


Articles

Supraregional Interlaboratory Quality-Control Survey for an Immunoradiometric Renin Assay

Adriano Piffanelli1a, Alberto Morganti2, Franco Mantero3, Antonio Cianetti4, Gian Carlo Zucchelli5, Gloria Giovannini1 and Dario Pelizzola1

1 Department of Experimental and Clinical Medicine, Section of Nuclear Medicine University, 44100 Ferrara, Italy;
2 Hypertension and Clinical Physiology Center, Institute of Clinical Medicine University, 20100 Milan, Italy;
3 Endocrinology Section University, 60100 Ancona, Italy;
4 Central Laboratory RIA Section, S. Camillo Hospital, 00100 Rome, Italy;
5 Institute of Clinical Physiology, National Center of Research, 56100 Pisa, Italy

aaddress correspondence to this author at: Department of Experimental and Clinical Medicine, Section of Nuclear Medicine, Via Luigi Borsari, 46, 44100 Ferrara, Italy; fax 39-0532-236589, e-mail pif{at}unife.it


   Introduction
Top
Introduction
References
 
For the last 20 years, the most widely used method for assessment of the renin-angiotensin system has been the plasma renin activity assay (1). Although the assay gives useful information on the enzymatic function of the renin molecule, the intrinsic characteristics of this method limit its analytical accuracy (2). Immunoradiometric assays for renin, developed in 1985, overcame this limitation of the enzymatic assay because the well-defined monoclonal antibodies provided the means for direct quantification of specific active forms of the enzyme molecule (3)(4). Nevertheless, a critical debate has developed over the use of these assays (5)(6)(7)(8)(9)(10).

A pilot study (11)(12) in a limited number of laboratories (eight Italian centers) found satisfactory indexes of precision for a direct immunoradiometric renin assay (Eria Diagnostics, Sanofi-Pasteur). In our previous experience, the inter- and intralaboratory reproducibility indices of this commercial immunoradiometric assay appeared to be better than those that had been achieved with an enzymatic assay (REN-CTK; Sorin Biomedica), with the differences probably being attributable to the greater complexity of the procedure for the latter assay (11).

Various reports have been published during the past 30 years describing useful tools to monitor the performance of immunoassays (13)(14). Regarding the active renin assay, it is of paramount importance to assess the methodologic accuracy, especially for "low renin" concentrations, which are clinically relevant (15)(16).

Here we describe the results of a supraregional quality-control program, open to laboratories performing direct renin assays with a commercially available immunoradiometric method. The program included 48 clinical laboratories studied over a 12-month period with results provided periodically to the participants.

Forty-eight Italian laboratories participated in the first phase of the program, which included the determination of nine reference samples of unknown renin content (one every 3 weeks) during a 6-month period. Once a month a report with the extrapolated "consensus mean" and bias (expressed as SD) of the laboratory was sent to every participant, and at the end of each program a final report carried "precision" and "accuracy" results for the nine sample determinations. No results of this multicenter survey were rejected as outliers.

For the first phase of the program (June 1998 through January 1999), reference samples covering a wide concentration range were prepared from three pools of plasma samples collected for routine assays of renin activity. The three pools contained the following theoretic concentrations: pool 1, 15 ng/L; pool 2, 50 ng/L; pool 3, 150 ng/L. Each vial contained 0.7 mL of lyophilized plasma. The expected renin concentration of each vial was not revealed to the participating laboratories.

Lyophilization (Edwards High Vacuum MFD 0.1) carried out under controlled conditions (pressure, 1 x 10-9 Pa; temperature, -20 °C; duration, 24 h) did not significantly influence the renin content of the samples.

Forty-nine laboratories participated in the second phase of the program (June 1999 through January 2000). The reference samples for this phase were prepared from normal plasma with or without the addition of the renin International Reference Preparation (IRP 68/356), which was established as the IRP for renin by the WHO Expert Committee on Biological Standardization (WHO ECBS–WHO TRS 565) (17). The pools were as follows: pool 1 contained normal plasma with 50 ng/L renin IRP [1 ng of IRP 68/356 is equivalent to 1.6 x 10-3 Goldblatt Units (GU), with 1 GU being identical to the Medical Research Council International Unit]; pool 2 contained normal plasma; pool 3 contained normal plasma with 110 ng/L renin IRP. The theoretic renin concentrations were 50, 1.7, and 110 ng/L for pools 1, 2, and 3, respectively.

As in the first phase of the quality-control program, each pool was divided into three identical series of vials for a total of nine vials per set (each vial contained 0.75 mL of lyophilized plasma). The lyophilization process was the same as for the first phase.

This quality-control program was open to laboratories performing renin assays with the commercial immunoradiometric assay provided by Eria Diagnostics (Sanofi-Pasteur). The first monoclonal antibody recognizes both the active and inactive forms of renin, whereas the second monoclonal antibody, labeled with 125I, recognizes specifically the active form of renin. The tubes were counted in a gamma counter (Cobra AutoGamma; Camberra Packard), and the renin concentration of unknown samples was calculated from a calibration curve generated with Medical Research Council human renin (1 ng = 1.6 x 10-3 GU; WHO 68/356). The detection limit of the assay was <1 ng/L for active renin at the half-life of the tracer. The interassay variation given by the manufacturer for renin concentrations of 8–269 ng/L was 14.5–2.7%. Each laboratory also periodically received its accuracy indices with respect to a working consensus mean.

Interlaboratory CVs during the first phase were 14–32% (Table 1 ); on the other hand, mean intralaboratory CVs for the same round, calculated for every laboratory on the three concentrations assayed three times, were 14–19% (Table 1 ). During the second phase, interlaboratory CVs were 16–46% (Table 1 ), and intralaboratory CVs for the second phase, calculated in the same way as for the first phase, were 16–30% (Table 1 ). The renin concentration range for the second phase included lower concentrations to allow evaluation of precision performance in this portion of the analytical interval.


View this table:
[in this window]
[in a new window]
 
Table 1. Results of the first and second phases of the renin quality-control program.

The survey presented here involved a large group of participating laboratories (n = 48) applying the same methodology. The long period of time over which the program was applied (12 months over 2 years) increased our confidence in the reliability of the results achieved.

Although the present overall results confirm the previous good reproducibility data obtained with the same immunometric method (11), the data reveal marked imprecision for lower renin concentrations. Blood concentrations of renin are particularly valuable and useful at low concentrations (18) and when the renin-angiotensin system is activated (15). Because various immunometric assays for active renin are used for clinical research (15)(16)(19), it would be advisable to validate each technique with a thorough quality-control program.


   Acknowledgments
 
We are indebted to our colleagues at 48 Italian centers who participated in the present study.


   References
Top
Introduction
References
 

  1. Sealey JE, Laragh JH. RIA of plasma renin activity. Semin Nucl Med 1975;5:189-202.[Medline] [Order article via Infotrieve]
  2. Sealey JE. Plasma renin activity and plasma prorenin assays. Clin Chem 1991;37:1811-1819.[Abstract/Free Full Text]
  3. Derkx FHM, De Bruin RJA, Van Gool JMG, Van den Hoek MJ, Beerendonk CCM, Rosmalen F, et al. Clinical validation of renin monoclonal antibody-based sandwich assays of renin and prorenin, and use of renin inhibitor to enhance prorenin immunoreactivity. Clin Chem 1996;42:1051-1063.[Abstract/Free Full Text]
  4. Simon D, Hartmann DJ, Badouaille G, Caillot G, Guyenne TT, Corvol T, et al. Two-site direct immunoassay specific for active renin. Clin Chem 1992;38:1959-1962.[Abstract]
  5. Sealey JE, Trenkwalder P, Gahnem F, Catanzaro D, Laragh JH. Plasma renin methodology: inadequate sensitivity and accuracy of direct renin assay for clinical applications compared with the traditional enzymatic plasma renin activity assay. J Hypertens 1995;13:27-30.[Web of Science][Medline] [Order article via Infotrieve]
  6. Menard J, Thanh-Tam G. Commentary: renin assays: a debate for clinicians, not only for specialists. J Hypertens 1995;13:367-369.[Web of Science][Medline] [Order article via Infotrieve]
  7. Nystrom F, Karlberg BE, Ohman KP. Serum angiotensin-converting enzyme activity correlates positively with plasma angiotensin II. A population-based study of ambulatory blood pressure and the renin-angiotensin system. J Hum Hypertens 1997;11:301-306.[Web of Science][Medline] [Order article via Infotrieve]
  8. Sealey JE, Laragh JH. Commentary: plasma renin methodology. J Hypertens 1995;13:371.[Web of Science][Medline] [Order article via Infotrieve]
  9. Sealey JE, Laragh JH. Renin and prorenin: advanced and declines in methodology. Clin Chem 1996;42:993-994.[Free Full Text]
  10. Deinum J, Derkx FHM, Schalekamp MADH. Improved immunoradiometric assay for plasma renin. Clin Chem 1999;45:847-854.[Abstract/Free Full Text]
  11. Morganti A, Pelizzola D, Mantero F, Gazzano G, Opocher G, Piffanelli A. Immunoradiometric versus enzymatic renin assay: results of the Italian Multicenter Comparative Study. J Hypertens 1995;13:19-26.[Web of Science][Medline] [Order article via Infotrieve]
  12. Morganti A, Pelizzola D, Mantero F, Gazzano G, Opocher G, Piffanelli A. On the Italian Multicenter Study for Standardization of Renin Measurement. [Authors’ Reply]. J Hypertens 1995;13:31.[Web of Science]
  13. Ekins RP. Immunoassay standardization. Scand J Clin Lab Invest 1991;51(Suppl 205):33-39.
  14. Sadler WA. Estimating imprecision of radioassays and related procedures: some considerations. Eur J Nucl Med 1991;18:863-865.[Web of Science][Medline] [Order article via Infotrieve]
  15. Hurwitz S, Potter B, Weiss RJ, Jeunemaitre X, Hopkins PN, Hunt SC, et al. Influence of sodium intake on the reliability of active renin as a measure of the renin-angiotensin system in essential hypertension. Am J Clin Pathol 2001;115:304-312.[Abstract/Free Full Text]
  16. Giacchè M, Vuagnat A, Hunt SC, Hopkins PN, Fisher NDL, Azizi M, et al. Aldosterone stimulation by angiotensin II. Influence of gender, plasma renin, and familial resemblance. Hypertension 2000;35:710-716.[Abstract/Free Full Text]
  17. WHO. Expert Committee on Biological Standardization (1974). 26th Report. WHO Technical Report Series No. 565. Geneva: WHO, 1975:11pp.
  18. Kruger C, Rauh M, Door HG. Immunoreactive renin concentrations in healthy children from birth to adolescence. Clin Chim Acta 1998;274:15-27.[Web of Science][Medline] [Order article via Infotrieve]
  19. Danser AHJ, Vankestern CAM, Bax WA, Tavenier M, Derkx FHM, Saxena PR, et al. Prorenin, renin, angiotensinogen and angiotensin-converting in normal and failing human hearts—evidence for renin binding. Circulation 1997;96:220-226.[Abstract/Free Full Text]



The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
D. J. Campbell, J. Nussberger, M. Stowasser, A.H. J. Danser, A. Morganti, E. Frandsen, and J. Menard
Activity Assays and Immunoassays for Plasma Renin and Prorenin: Information Provided and Precautions Necessary for Accurate Measurement
Clin. Chem., May 1, 2009; 55(5): 867 - 877.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Piffanelli, A.
Right arrow Articles by Pelizzola, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Piffanelli, A.
Right arrow Articles by Pelizzola, D.
Related Collections
Right arrow Laboratory Management
Right arrow Endocrinology and Metabolism


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS