Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 48: 691-698, 2002;
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (91)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bonini, P.
Right arrow Articles by Rubboli, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bonini, P.
Right arrow Articles by Rubboli, F.
Related Collections
Right arrow Laboratory Management
(Clinical Chemistry. 2002;48:691-698.)
© 2002 American Association for Clinical Chemistry, Inc.


Minireview

Errors in Laboratory Medicine

Pierangelo Bonini1,2a, Mario Plebani3, Ferruccio Ceriotti2 and Francesca Rubboli2

1 Università Vita-Salute San Raffaele, Cattedra di Biochimica Clinica, Via Olgettina 58, 20132 Milan, Italy.

2 Istituto Scientifico H. S. Raffaele, Servizio Integrato di Medicina di Laboratorio, Via Olgettina 60, 20132 Milan, Italy.

3 Servizio di Medicina di Laboratorio, Azienda Ospedaliera di Padova, Via Giustiniani 2, 35100 Padova, Italy.

aAuthor for correspondence. Fax 39-02-2643-2640; e-mail bonini.pierangelo{at}hsr.it.


Abstract

Background: The problem of medical errors has recently received a great deal of attention, which will probably increase. In this minireview, we focus on this issue in the fields of laboratory medicine and blood transfusion.

Methods: We conducted several MEDLINE queries and searched the literature by hand. Searches were limited to the last 8 years to identify results that were not biased by obsolete technology. In addition, data on the frequency and type of preanalytical errors in our institution were collected.

Results: Our search revealed large heterogeneity in study designs and quality on this topic as well as relatively few available data and the lack of a shared definition of "laboratory error" (also referred to as "blunder", "mistake", "problem", or "defect"). Despite these limitations, there was considerable concordance on the distribution of errors throughout the laboratory working process: most occurred in the pre- or postanalytical phases, whereas a minority (13–32% according to the studies) occurred in the analytical portion. The reported frequency of errors was related to how they were identified: when a careful process analysis was performed, substantially more errors were discovered than when studies relied on complaints or report of near accidents.

Conclusions: The large heterogeneity of literature on laboratory errors together with the prevalence of evidence that most errors occur in the preanalytical phase suggest the implementation of a more rigorous methodology for error detection and classification and the adoption of proper technologies for error reduction. Clinical audits should be used as a tool to detect errors caused by organizational problems outside the laboratory.

Measuring and improving laboratory-related patient outcomes require methods that relate the total quality of laboratory information to more effective patient management, including diagnosis, treatment of disease, clinical monitoring, and disease prevention. The improvement in analytical quality, documented through proficiency testing, should guarantee that the actual performances of clinical laboratories are suitable for improving a patient’s health. Furthermore, increased attention to patients’ needs is demonstrated by efforts to improve the quality of the entire service provided, e.g., reduction of the turnaround time (TAT). However, improvement of laboratory performance does not automatically indicate a reduction in the number of errors, both analytical and organizational. Even certification or accreditation processes focus attention more on the general performance of the laboratory than on events such as errors that, by their very nature, are considered exceptional. Moreover, the lack of a universally accepted definition of error and above all of "allowable error rate", reduces the possibility of evaluating the impact of laboratory error on patient outcomes.

Although there is abundant scientific literature dealing with increased laboratory quality (mainly analytical), the literature on errors in laboratory medicine is scarce. One reason for this, in addition to the insufficient attention paid to the problem, is the practical difficulty in reporting and measuring the number of errors.

In fact, there are several limitations in the study designs of reports dealing with the frequency and types of mistakes in the clinical laboratory.

The first limitation is that most of the studies focus simply on analytical errors, which represent only a percentage of the errors in the total testing process, which includes all pre-, intra-, and postanalytical phases. Other studies are based on methodologies, such as the split-specimen design, that are insensitive to total testing process problems that can occur before specimens are collected and after results are obtained by the analytical process (1)(2).

The second limitation is that it is possible, even probable, that the most frequent preanalytical errors are represented by an inappropriate choice of laboratory tests or panel of tests and that most postanalytical errors derive from inappropriate interpretation and utilization of laboratory results. Although large differences in laboratory test requests and utilization between hospitals, even within the same country, have been described recently (3), a systematic review of laboratory clinical audits has demonstrated that many studies identifying inappropriate laboratory use are based on implicit or explicit criteria not meeting methodologic standards (4).

Regarding the postanalytical phase, only a few studies are available that demonstrate the inappropriate utilization of or response to laboratory results. It has recently been demonstrated that the introduction of new technologic facilities (online connection between laboratory and wards) without proper organization can worsen, rather than improve the communications between laboratories and clinicians (5). The lack of immediate notification and/or clinical utilization of a critical value can have an effect on outcome as negative as a wrong result. As pointed out by Lundberg in an outstanding editorial in JAMA (6), proper interpretation and action must be accomplished before the laboratory test loops are actually completed.

The third limitation is that, apart from a reluctance in reporting their own errors, it is extremely difficult for laboratories to identify all errors because many errors will neither produce detectable abnormal results nor raise questions for the user. Although their observations were not based on actual data, Goldschmidt and Lent (7) estimated that up to 75% of errors produce results still within the reference intervals, that ~12.5% produce wrong results that are so absurd that they are not considered clinically, and that the remaining 12.5% of laboratory errors may have an effect on patient health.

The fourth limitation is that new pathophysiologic insights and the development of highly specific and sensitive laboratory tests have changed the relationship between laboratory information and the gold standards. This is the case for myocardial damage in acute coronary syndromes, in which the measurement of cardiac troponins is the method of choice for detecting small myocardial injuries. The same is true for molecular analyses to evaluate disease susceptibility. In this and other clinical situations where it is difficult or impossible to compare laboratory results to gold standards, possible errors should be identified by evaluating the relationship between laboratory information and medical outcomes.

In contrast to the above-described situation, which was derived essentially from the scientific literature, "errors in medicine", including laboratory mistakes and problems at blood banks, are frequently cited by the mass media even if the attention is especially driven by errors in other healthcare sectors (e.g., drugs or surgery). In many of these reports, it is suggested that the reported errors are only the tip of the iceberg and that the consequences on patient outcome are likely to be worse than described. For this reason, we reviewed the scientific literature on errors in laboratory medicine and blood banks.

For laboratory medicine, we searched the MEDLINE database from January 1994 to June 2001 by crossing several headings: "laboratories, diagnostic services"; "chemistry, clinical"; "diagnostic errors"; and "medical errors". All articles with the words "blunders OR problems OR errors OR mistakes AND laboratory" in the title were also selected. Additional hand searching was performed, starting with the references of the selected papers. Finally, only articles reporting information on the total testing process (including the preanalytical, analytical, and postanalytical phases, not just one of them) in which data were obtained by direct collection (not just by questionnaires) were chosen and are compared in Table 1 .


View this table:
[in this window]
[in a new window]
 
Table 1. Review of the literature on laboratory errors.

For blood banks, we searched the MEDLINE database from January 1992 to June 2001 by crossing several headings: blood transfusion/st (standards); blood group, incompatibility/co (complications); blood transfusion/ae (adverse effects); quality of health care; quality control quality assurance; health care/sn (statistics & numerical data); quality assurance, health care/og (organization & administration); quality assurance, health care/st (standards); safety; medication errors; and patient identification systems/st (standards). Starting from these results, we performed additional hand searching and selection. The results are presented in Table 2 and represent only those studies including more than three hospitals or a data collection period longer than 1 year. Only the most recent literature was analyzed because advances in laboratory informatics, automation, and analytical quality would make comparison to older studies nearly impossible (see also Table 3 ).


View this table:
[in this window]
[in a new window]
 
Table 2A. Review of transfusion errors.


View this table:
[in this window]
[in a new window]
 
Table 2B. Continued.


View this table:
[in this window]
[in a new window]
 
Table 3. Error rates in clinical laboratories.

The most relevant features of the studies involving laboratory errors are summarized in Table 1Up : (a) data collection period; (b) number of tests considered; (c) number of patients involved; (d) total number of errors and their relative frequencies; (e) distribution of errors in the preanalytical, analytical, and postanalytical phases; (f) errors caused by patient misidentification; and (g) effect of errors on patient outcome. The findings confirm that there is a very limited number of studies on this topic and that those that exist are very heterogeneous. These studies used different data collection approaches [process analysis (8), audit and questionnaires (9), and collection of complaints (7)], the time span for data collection ranged from 3 months to 10 years, and the laboratory sectors examined were very different. Another obstacle to comparing these studies or reaching general conclusions is that in some reports, the errors are indexed to patients, whereas in others they are indexed to tests performed. Data have been partially re-elaborated to calculate frequencies, to divide them into the phases of the working process, and to harmonize the categories of relevance of the effect on patient outcome. It is evident from the data shown that the collection method has a very strong influence on both the prevalence and the error types. For example, when data collection was based on complaints (7) or on more or less fortuitous finding of blunders (10), the errors reported were mainly attributable to misidentification, and their number was very low: 133 errors in 6 years (7) or 0.05% (10). On the other hand, when a careful review of the whole working process was performed (8), the number of errors increased substantially (189 in 3 months, 0.47% of the test results). In this last report (8), misidentification errors represented only 2.6% of all errors, but their absolute frequency was more than double that reported by Lapworth and Teal (10). The heterogeneity of the literature is even more obvious in Table 3Up , where only the frequencies of errors from these and older studies are reported.

One common finding in this review of data on laboratory errors is that even when different study designs, patient numbers, and discovery techniques were used, the distribution of errors across the different phases of the entire testing process was very similar. This comes through despite the large differences in actual error frequencies. In particular, all available studies demonstrated that a large percentage of laboratory errors occur in the pre- and postanalytical phases, with fewer mistakes occurring during the analytical step. Indirect evidence of the importance of the preanalytical phase stems from the results of several recent studies. In the College of American Pathologists Q-Probe study (11) performed in 660 institutions, a total of 5514 of 114 934 outpatients requisitions (4.8%) were associated with at least one type of order entry error. In 1658 (1.4%) of the requisitions, one or more tests on the requisition were not ordered in the laboratory computer, whereas in 1221 cases (1.1%) at least one test was ordered in the computer that had not appeared on the requisition. A total of 2130 requisitions (1.9%) contained one or more physician name discrepancies between the requisition and the laboratory computer entry, Finally, in 943 requisitions (0.8%), an incorrect test priority was entered for at least one of the requested tests. In an Australian survey on transcription and analytical errors, the transcription error rate was up to 39%, the most frequent types of errors being associated with misidentification of the requested tests, the requesting doctor, and/or the patient. The laboratory with the worst performance had errors in 46% of requests, but even the three best-performing laboratories achieved an error-free reporting of only >=85%, with only one achieving 95% (12). Another indirect indicator of the importance of preanalytical processes stems from studies that have demonstrated that the evaluation of specimen adequacy is a critical preanalytical factor affecting test result accuracy and usefulness (13).

Shown in Table 4 are the errors, relative only to the preanalytical phase, detected in the San Raffaele Hospital Laboratory in 1 year. All the preanalytical problems that prevented us from reporting a result were automatically collected and divided by in- and outpatients. The data indicate the number of missing test results attributable to a specific type of preanalytical problem, not the number of problematic samples (e.g., a single hemolyzed tube could have caused the absence of 20 or more results). The difference between in- and outpatients is noteworthy: there were a total of 15 503 errors in 2 583 850 test results (0.60%) for inpatients vs 792 errors in 2 032 133 tests results (0.039%) for outpatients. There are multiple reasons for this difference: (a) direct control of sample drawing for the outpatients vs blood drawing performed by ward personnel, who have a high degree of turnover and lower skill, and (b) the higher complexity of the examinations performed and multiple blood drawings for the inpatients.


View this table:
[in this window]
[in a new window]
 
Table 4. Types of preanalytical errors registered during the year 2000 at the Laboratory of San Raffaele Hospital.

Guidelines for collecting samples and for evaluating submitted specimens are therefore essential because acceptance of improper specimens for analysis may lead to erroneous information that could affect patient care, but only by monitoring on a regular basis the rejected specimens and identifying factors associated with the rejection can we avoid errors and promote continuous quality improvement of laboratory service (14). Moreover, an increasing body of evidence demonstrates the importance of the postanalytical phase for monitoring and improving the TAT (15), for improving the appropriateness of reference intervals (16), and for allowing more objective validation and interpretation of data by use of expert systems (17)(18). Recently, there has been growing interest in implementing and disseminating guidelines for the provision of interpretative comments on laboratory reports (19). To avoid possible errors, this critical activity requires that the laboratory personnel receive adequate training; moreover, there is the need for quality assurance in providing interpretative comments and for auditing this activity (20).

We also paid attention to the area of blood banking. This field is strictly related to laboratory medicine and has very similar working methodologies, which are always being subjected to a very high degree of control because of the high degree of related risk. A report from the College of American Pathologists in collaboration with the CDC Outcomes Working Group (21) describes error stratification in the working process for clinical laboratories similar to the one reported in Table 1Up . Of >88 000 defects, 41% were observed in the preanalytical phase of testing, 55% in the postanalytical phase, and only 4% in the analytical phase (21).

Table 2Up Up summarizes a selection of the published reports on errors in transfusion medicine, taking into consideration the effect of the error on the patient. In this case, the essential elements have been extracted: duration of data collection; frequency of misidentification errors; and effect of the error on the patient’s health. Once again the heterogeneity of the results of the different studies is noteworthy; particularly evident is the very high number of risks of error (4.7% of the transfusions) reported by Baele et al. (22). Point 3 below presents a tentative explanation for this fact.

The heterogeneity of the reported data, in addition to underlining the total lack of a benchmark, the lack of a definition of "maximum allowable error rate", and the lack of a classification of errors, puts in evidence some aspects of critical relevance:


References

  1. Shahangian S, Krolak JM, Gaunt EE. A system to monitor a portion of the total testing process in medical clinics and laboratories: feasibility of a split-specimen design. Arch Pathol Lab Med 1998;122:503-511.[ISI][Medline] [Order article via Infotrieve]
  2. Shahangian S, Cohn RD, Gaunt EE. System to monitor a portion of the total testing process in medical clinics and laboratories: evaluation of a split-specimen design. Clin Chem 1999;45:269-280.[Abstract/Free Full Text]
  3. Larsson A, Palmer M, Hulten G, Tryding N. Large differences in laboratory utilization between hospitals in Sweden. Clin Chem Lab Med 2000;38:383-389.[ISI][Medline] [Order article via Infotrieve]
  4. van Walraven C, Naylor D. Do we know what inappropriate laboratory utilization is? A systematic review of laboratory clinical audits. JAMA 1998;280:550-558.[Abstract/Free Full Text]
  5. Kilpatrick ES, Holding S. Use of computer terminals on wards to access emergency test results: a retrospective audit. BMJ 2001;322:1101-1103.[Abstract/Free Full Text]
  6. Lundberg GD. The need for an outcomes research agenda for clinical laboratory testing. JAMA 1998;280:565-566.[Free Full Text]
  7. Goldschmidt HMJ, Lent RW. Gross errors and work flow analysis in the clinical laboratory. Klin Biochem Metab 1995;3:131-140.
  8. Plebani M, Carraro P. Mistakes in a stat laboratory: types and frequency. Clin Chem 1997;43:1348-1351.[Abstract/Free Full Text]
  9. Hofgärtner WT, Tait JF. Frequency of problems during clinical molecular-genetic testing. Am J Clin Pathol 1999;112:14-21.[ISI][Medline] [Order article via Infotrieve]
  10. Lapworth R, Teal TK. Laboratory blunders revisited. Ann Clin Biochem 1994;31:78-84.
  11. Valenstein P, Meier F. Outpatient order accuracy. A college of American Pathologists Q-Probes study of requisition order entry accuracy in 660 institutions. Arch Pathol Lab Med 1999;123:1145-1150.[Medline] [Order article via Infotrieve]
  12. Khoury M, Burnett L, Mackay MA. Error rate in Australian chemical pathology laboratories. Med J Aust 1996;165:128-130.[ISI][Medline] [Order article via Infotrieve]
  13. Jones BA, Calam RR, Howanitz PJ. Chemistry specimen acceptability. Arch Pathol Lab Med 1997;121:19-26.[ISI][Medline] [Order article via Infotrieve]
  14. Carraro P, Servidio G, Plebani M. Hemolyzed specimens: a reason for rejection or a clinical challenge?. Clin Chem 2000;46:306-307.[Free Full Text]
  15. Negri M, Carraro P, Caenaro G, Cappelletti P, Giavarina D, Mezzena G, et al. External quality assessment of stat test intralaboratory turnaround times. Clin Chem Lab Med 1998;36:867-870.[Medline] [Order article via Infotrieve]
  16. Zardo L, Secchiero S, Sciacovelli L, Bonvicini P, Plebani M. Reference intervals: are interlaboratory differences appropriate?. Clin Chem Lab Med 1999;37:1131-1133.[Medline] [Order article via Infotrieve]
  17. Smith BJ, McNeely MDD. The influence of an expert system for testing ordering and interpretation of laboratory investigations. Clin Chem 1999;45:1168-1175.[Abstract/Free Full Text]
  18. Oosterhuis WP, Ulenkate HJLM, Goldschmidt HMJ. Evaluation of LabRespond, a new automated validation system for clinical laboratory test results. Clin Chem 2000;46:1811-1817.[Abstract/Free Full Text]
  19. . The Royal College of Pathologists. Guidelines for the provision of interpretative comments on biochemical reports. Bull R Coll Pathol 1998;104:25.
  20. Marshall WJ, Challand GS. Provision of interpretative comments on biochemical reports. Ann Clin Biochem 2000;37:758-763.
  21. Boone DJ, Steindel SD, Herron R, Howanitz PJ, Bachner P, Meier F, et al. Transfusion medicine monitoring practices. Arch Pathol Lab Med 1995;119:999-1006.[ISI][Medline] [Order article via Infotrieve]
  22. Baele PL, De Bruyere M, Deneys V, Dupont E, Flament J, Lambermont M, et al. Bedside transfusion errors. A prospective survey by the Belgium SAnGUIS Group. Vox Sang 1994;66:117-121.[ISI][Medline] [Order article via Infotrieve]
  23. Witte DL, VanNess SA, Angstadt DS, Pennell BJ. Errors, mistakes, blunders, outliers, or unacceptable results: how many?. Clin Chem 1997;43:1352-1356.[Abstract/Free Full Text]
  24. Hurst J, Nickel K, Hilborne LH. Are physicians’ office laboratory results of comparable quality to those produced in other laboratory settings?. JAMA 1998;279:468-471.[Abstract/Free Full Text]
  25. Stull TM, Hearn TL, Hancock JS, Handsfield JH, Collins CL. Variation in proficiency testing performance by testing site. JAMA 1998;279:463-467.[Abstract/Free Full Text]
  26. Jenny RW, Jackson-Tarentino KY. Causes of unsatisfactory performance in proficiency testing. Clin Chem 2000;46:89-99.[Abstract/Free Full Text]
  27. Cembrowski GS, Carey RN. Adding value to proficiency testing programs [Editorial]. Clin Chem 2000;46:7-8.[Free Full Text]
  28. Blumenthal D. The errors of our ways [Editorial]. Clin Chem 1997;43:1305.[Free Full Text]
  29. Gray TA. Clinical governance. Ann Clin Biochem 2000;37:9-15.
  30. Bonini PA, Sanna A. A kiosk and a smart cart to bring the hospital services closer to the patient. LabAutomation2000 Final Conference Program, January 22–26, 2000, Palm Springs, CA:85..
  31. Bonini PA, Rubboli F. Risk of errors in complex health care delivery systems. A multidimensional approach [Abstract]. Clin Chem Lab Med 2001;39:77.
  32. Shulman IA, Lohr K, Derdiarian AK, Picukaric JM. Monitoring transfusionist practices: a strategy for improving transfusion safety. Transfusion 1994;34:11-15.[Medline] [Order article via Infotrieve]
  33. Serig DI. Radiopharmaceutical misadministrations: what’s wrong. Bogner MS eds. Human error in medicine 1994:179-195 LEA Publishers Hillsdale, NJ. .
  34. Sanna A, Wilikens M, Borio di Tigliole A, Klein G, Bonini PA. Safety procedures for identification of patient related object. CEN Document N00-049. http://www.centc251.org/tcmeet/doclist/doclist2000.htm (Accessed October 2001)..
  35. Leape LL, Woods DD, Hatlie MJ, Kizer KW, Schroeder SA, Lundberg GD. Promoting patient safety by preventing medical error. JAMA 1998;280:1444-1447.[Free Full Text]
  36. Nutting PA, Main DS, Fischer PM, Stull TM, Pontious M, Seifert M, et al. Problems in laboratory testing in primary care. JAMA 1996;275:635-639.[Abstract]
  37. Stahl M, Lund ED, Brandslund I. Reasons for a laboratory’s inability to report results for requested analytical tests. Clin Chem 1998;44:2195-2197.[Free Full Text]
  38. Renner SW, Howanitz PJ, Bachner P. Wristband identification error reporting in 712 hospitals. A College of American Pathologists’ Q-Probes study of quality issues in transfusion practice. Arch Pathol Lab Med 1993;117:573-577.[Medline] [Order article via Infotrieve]
  39. McClelland DBL, Phillips P. Errors in blood transfusion in Britain: survey of hospital haematology departments. BMJ 1994;308:1205-1206.[Free Full Text]
  40. Linden JV, Kaplan HS. Transfusion errors: causes and effects. Transfus Med Rev 1994;8:169-183.[ISI][Medline] [Order article via Infotrieve]
  41. Taswell HF, Galbreath JL, Harmsen WS. Errors in transfusion medicine. Detection, analysis, frequency, and prevention. Arch Pathol Lab Med 1994;118:405-410.[ISI][Medline] [Order article via Infotrieve]
  42. Linden JV. Decrease in frequency of transfusion fatalities. Transfusion 1997;37:243-244.[ISI][Medline] [Order article via Infotrieve]
  43. Williamson LM, Lowe S, Love EM, Cohen H, Soldan K, McClelland DB, et al. Serious hazards of transfusion (SHOT) initiative: analysis of the first two annual reports. BMJ 1999;319:16-19.[Abstract/Free Full Text]
  44. Linden JV, Wagner K, Voytovich AE, Sheehan J. Transfusion errors in New York State: an analysis of 10 years’ experience. Transfusion 2000;40:1207-1213.[ISI][Medline] [Order article via Infotrieve]
  45. McSwiney RR, Woodrow DA. Types of error within a clinical laboratory. J Med Lab Technol 1969;26:340-346.[Medline] [Order article via Infotrieve]
  46. Souverijn JHM, Swaanenburg J, Visser R. Onderzoek naar de nauwkeurigheid waarmee monsters worden geselecteerd op een klinisch-chemisch laboratorium. Tijdschrift NVKC 1980;6:183-184.
  47. Chambers AM, Elder J, O’Reilly DS. The blunder-rate in a clinical biochemistry service. Ann Clin Biochem 1986;23:470-473.
  48. Boone DJ. Comment on "Random errors in haematology tests". Clin Lab Haematol 1990;12(Suppl 1):169-170.[Medline] [Order article via Infotrieve]



The following articles in journals at HighWire Press have cited this article:


Home page
Biophys. JHome page
R. R. Pompano, H.-W. Li, and R. F. Ismagilov
Rate of Mixing Controls Rate and Outcome of Autocatalytic Processes: Theory and Microfluidic Experiments with Chemical Reactions and Blood Coagulation
Biophys. J., August 1, 2008; 95(3): 1531 - 1543.
[Abstract] [Full Text] [PDF]


Home page
Ann Clin BiochemHome page
M. J O'Kane, P L M. Lynch, and N. McGowan
The development of a system for the reporting, classification and grading of quality failures in the clinical biochemistry laboratory
Ann Clin Biochem, March 1, 2008; 45(2): 129 - 134.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
P. Carraro and M. Plebani
Errors in a Stat Laboratory: Types and Frequencies 10 Years Later
Clin. Chem., July 1, 2007; 53(7): 1338 - 1342.
[Abstract] [Full Text] [PDF]


Home page
Annals of Clinical & Laboratory ScienceHome page
G. M. Reisfield, E. Salazar, and R. L. Bertholf
Rational Use and Interpretation of Urine Drug Testing in Chronic Opioid Therapy
Ann. Clin. Lab. Sci., January 1, 2007; 37(4): 301 - 314.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
K. G. Crone, M. B. Muraski, J. D. Skeel, L. Love-Gregory, J. H. Ladenson, and A. M. Gronowski
Between a Rock and a Hard Place: Disclosing Medical Errors
Clin. Chem., September 1, 2006; 52(9): 1809 - 1814.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
G. Lippi, A. Bassi, G. Brocco, M. Montagnana, G. L. Salvagno, and G. C. Guidi
Preanalytic error tracking in a laboratory medicine department: results of a 1-year experience.
Clin. Chem., July 1, 2006; 52(7): 1442 - 1443.
[Full Text] [PDF]


Home page
J. Clin. Microbiol.Home page
S. Yuan, M. L. Astion, J. Schapiro, and A. P. Limaye
Clinical Impact Associated with Corrected Results in Clinical Microbiology Testing
J. Clin. Microbiol., May 1, 2005; 43(5): 2188 - 2193.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
R. Rej
Clinical Chemistry through Clinical Chemistry: A Journal Timeline
Clin. Chem., December 1, 2004; 50(12): 2415 - 2458.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
D. Dix and J. H Ladenson
Priority In Clinical Chemistry: Does It Match International Public Health Need? * Comment on Dix
Clin. Chem., October 1, 2003; 49(10): 1712 - 1714.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
E. J. Giltay, J. M. Geleijnse, E. G. Schouten, M. B. Katan, and D. Kromhout
High Stability of Markers of Cardiovascular Risk in Blood Samples
Clin. Chem., April 1, 2003; 49(4): 652 - 655.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (91)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bonini, P.
Right arrow Articles by Rubboli, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bonini, P.
Right arrow Articles by Rubboli, F.
Related Collections
Right arrow Laboratory Management


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS