Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 48: 796, 2002;
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow A correction has been published
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (10)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hawkins, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hawkins, R.
Related Collections
Right arrow General Clinical Chemistry
(Clinical Chemistry. 2002;48:796.)
© 2002 American Association for Clinical Chemistry, Inc.


Letters

Variability in Potassium/Hemoglobin Ratios for Hemolysis Correction

Robert Hawkins1a

1 Department of Pathology and Laboratory Medicine Tan Tock Seng Hospital 11 Jalan Tan Tock Seng Singapore 308433

aFax 65-253-6507; e-mail Robert Hawkins{at}ttsh.com.sg.


To the Editor:

Because the increase in plasma potassium in hemolyzed specimens is linearly related to hemoglobin concentration (1), knowledge of the potassium/hemoglobin ratio can allow estimation of the magnitude of increase in plasma potassium. Previous estimates of the potassium/hemoglobin ratio have evaluated only a few apparently healthy volunteers (2)(3)(4). Interindividual differences, particularly in diseased populations, could produce variability in correction factor determination. This letter describes the interindividual variability in the potassium/hemoglobin ratio for in vitro hemolysis in 100 hospitalized patients.

Erythrocyte hemolysates were prepared by the procedure of Meites (5). Briefly, the erythrocytes from lithium-heparin-blood samples from 100 medical and surgical inpatients were separated by centrifugation at 2500g within 1 h of collection, washed three times with isotonic saline, and then lysed by the addition of an equal volume of distilled water. After freezing overnight and thawing, the hemolysates were centrifuged at 2500g for 30 min to remove the stroma.

For each of the 100 patient hemolysate samples, 100 µL of hemolysate was added to 2 mL of a common pooled serum to produce a severely hemolyzed sample. This was diluted in the common pooled serum to form a series of nine equispaced, linearly related samples. Each series of the diluted samples was analyzed in duplicate (same batch) for potassium (reported to two decimal places with an indirect ion-selective electrode) and hemolysis index (multiwavelength spectrophotometry with saline as the reagent) on a Roche Diagnostics 917 clinical chemistry analyzer. Pearson correlation coefficient calculation and Deming model linear regression analysis by Analyse-It add-on software were performed for each dilution series, and the slope of the potassium/hemoglobin relationship was noted.

The range of hemoglobin concentrations tested was 50–6000 mg/L. Within-batch CVs were as follows: potassium, 0.4%; hemoglobin, 2%. The range of correlation coefficients for the 100 dilution series was 0.99–1.00, confirming the linear relationship between potassium and hemoglobin. The median potassium/hemoglobin (mmol/g) ratio was 28.0, with a mean of 28.4, and the 95% population limits were 21.0 and 34.5 (Fig. 1 ). Although the population range included published individual experimental values (1), the median and mean were lower than other individual estimates (1)(2)(3)(4)(6)(7). There was also a substantial difference between the 2.5 and 97.5 percentiles, which would create difficulty in the choice of ratio when correcting potassium values for hemolysis in a given case. Thus, because of the variability in the potassium/hemoglobin ratio demonstrated here, the correction of potassium increase in specimens exhibiting in vitro hemolysis is not advocated.



View larger version (16K):
[in this window]
[in a new window]
 
Figure 1. Distribution of potassium/hemoglobin correction ratios in 100 hospitalized patients.


References

  1. Jay D, Provasek D. Characterization and mathematical correction of hemolysis interference in selected Hitachi 717 assays. Clin Chem 1993;39:1804-1810.[Abstract]
  2. Sonntag O. Haemolysis as an interference factor in clinical chemistry. J Clin Chem Clin Biochem 1986;24:127-139.[ISI][Medline] [Order article via Infotrieve]
  3. Brydon W, Roberts L. The effect of haemolysis on the determination of plasma constituents. Clin Chim Acta 1972;41:435-438.[ISI][Medline] [Order article via Infotrieve]
  4. Frank J, Bermes E, Bickel M, Watkins B. Effect of in vitro hemolysis on chemical values for serum. Clin Chem 1978;24:1966-1970.[Abstract/Free Full Text]
  5. Meites S. Reproducibly simulating hemolysis, for evaluating its interference with chemical methods [Letter]. Clin Chem 1973;19:1319.
  6. Caraway W. Chemical and diagnostic specificity of laboratory tests. Am J Clin Pathol 1962;37:445-464.[ISI][Medline] [Order article via Infotrieve]
  7. Mather A, Mackie N. Effects of hemolysis on serum electrolyte values. Clin Chem 1960;6:223-227.[Abstract]



The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
G. Dimeski
Effects of Hemolysis on the Roche Ammonia Method for Hitachi Analyzers
Clin. Chem., May 1, 2004; 50(5): 976 - 977.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
R. Hawkins
Measurement of Whole-Blood Potassium--Is It Clinically Safe?
Clin. Chem., December 1, 2003; 49(12): 2105 - 2106.
[Full Text] [PDF]

eLetters:

Read all eLetters

Magnitude error in K/Hb ratio values
Robert C Hawkins
Clinical Chemistry Online, 29 Sep 2003 [Full text]

This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow A correction has been published
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow View responses
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (10)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hawkins, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hawkins, R.
Related Collections
Right arrow General Clinical Chemistry


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS