Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 49: 525-526, 2003; 10.1373/49.3.525
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (14)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Swinkels, D. W.
Right arrow Articles by de Kok, J. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Swinkels, D. W.
Right arrow Articles by de Kok, J. B.
Related Collections
Right arrow Molecular Diagnostics and Genetics
(Clinical Chemistry. 2003;49:525-526.)
© 2003 American Association for Clinical Chemistry, Inc.


Letters to the Editor

Effects of Blood-Processing Protocols on Cell-free DNA Quantification in Plasma

Dorine W. Swinkels1a, Erwin Wiegerinck1, Eric A.P. Steegers2 and Jacques B. de Kok1

1 Department of Clinical Chemistry, University Medical Centre Nijmegen, 6500 HB Nijmegen, The Netherlands

2 Department of Obstetrics and Gynaecology, University Hospital Rotterdam, 3000 CA Rotterdam, The Netherlands

aAddress correspondence to this author at: Department of Clinical Chemistry/564, University Medical Centre Nijmegen, PO Box 9101, 6500 HB Nijmegen, The Netherlands. Fax 31-243541743; e-mail D.Swinkels{at}akc.umcn.nl.


To the Editor:

Recently, qualitative analysis of cell-free DNA in blood plasma has attracted much interest for the diagnosis of cancer, fetal gender, Rhesus D status, and inherited disorders (1)(2). Other studies have shown that quantification of total plasma DNA may indicate fetal chromosomal aneuploidies and pregnancy-associated complications or the presence/recurrence of cancer (1)(3)(4). Irrespective of the type of study (qualitative or quantitative DNA analysis), it is important that cell-free plasma DNA is not contaminated with cellular DNA that interferes with analysis and accurate quantification.

To prevent cellular DNA contamination, Chiu et al. (5) emphasized the need of preanalytical standardization of blood-processing protocols. The authors note that after centrifugation of blood at a low speed (800g), the amount of isolated DNA from plasma is affected by the presence of cells that remain in the plasma fraction. An additional centrifugation step (16 000g) or filtering of the plasma is necessary to produce absolutely cell-free plasma DNA. Because most laboratories, including ours, centrifuge blood at relatively low speeds (800–1500g) and store plasma without additional treatment, these results may have a serious impact on the usefulness of previously collected plasma samples for retrospective DNA analysis/quantification.

To confirm the results of Chiu et al. (5), we collected EDTA blood in 7-mL Vacutainer Tubes from 18 healthy women with uncomplicated pregnancies, attending the outpatient clinic of the University Medical Centre Nijmegen, after 21 weeks of gestation. Blood was centrifuged at 800g for 10 min. The plasma supernatant was carefully removed to ~0.5 cm above the buffy coat layer, homogenized, and divided into two portions: fractions A (400 µL) and B (450 µL). Fraction B was centrifuged additionally at 16 000g for 5 min, and 400 µL of the supernatant was transferred to a new tube. All fractions were processed within 3 h after collection and stored at -20 °C for at least 1 month. After thawing, the DNA in the fractions was extracted exactly according to the protocol of Chiu et al. (5). Both fractions A and B from each pregnant woman were processed in the same batches during the isolation and quantification procedures. Copies of the albumin gene were quantified with real-time PCR and transformed to cell-equivalents/mL of plasma (CE/mL), as described previously (3).

The quantification results for plasma fractions A and B from 18 pregnant women are shown in Fig. 1A . Although the median number of cell-equivalents in fractions B (422 CE/mL) correlated well with the results of Chiu et al. (5), surprisingly we detected no significant amounts of additional DNA (from cellular origin) in fractions A. Obviously, in our samples, all cellular DNA had been removed from the plasma by centrifugation at 800g. After careful reanalysis of the protocol of Chiu et al., we could identify only a single difference with our procedure: we collected blood in 7-mL EDTA collection tubes instead of 10-mL tubes.



View larger version (9K):
[in this window]
[in a new window]
 
Figure 1. Albumin concentrations in plasma from pregnant (A) and nonpregnant (B) women.

(A), albumin concentrations (CE/mL) isolated from plasma samples obtained from 18 pregnant women, collected in 7-mL EDTA-blood Vacutainer Tubes. The tube volume (7.0 mL) and centrifugal forces (800g and 16 000g) before plasma collection and storage at -20 °C are shown on the x axes. Fraction A, median, 485 CE/mL [95% confidence interval (CI), 37–1207 CE/mL]; fraction B, median, 422 CE/mL (95% CI, 227-1911 CE/mL). A two-sided paired t-test showed no significant difference ({rho} = 0.27) in albumin concentrations between fractions A and B. (B), albumin concentrations isolated from plasma samples obtained from 10 nonpregnant donors, collected in 10- and 7-mL EDTA-blood Vacutainer Tubes. High-speed centrifugation (16 000g) occurred either before storage (fraction B) or after storage at -20 °C (fraction C). Fraction A, median, 24 936 CE/mL (95% CI, 1069–123 079 CE/mL); fraction B, median, 480 CE/mL (95% CI, 203–897 CE/mL); fraction C, median, 453 CE/mL (95% CI, 272–961 CE/mL); fraction D, median, 682 CE/mL (95% CI, 216-2652 CE/mL). A two-sided paired t-test showed a significant difference ({rho} = 0.01) in albumin concentrations between fractions A and B. Differences between other pairs of fractions (B and C, B and D, C and D) were not significant ({rho} = 0.57, 0.25, and 0.28, respectively).

To demonstrate the possible effect of this difference, we performed an additional experiment in which we collected blood from 10 nonpregnant donors into both 10- and 7-mL tubes. Blood and plasma were processed as described before. In these samples, after DNA isolation, contaminating cellular DNA was still present in the plasma fraction of the 10-mL collection tubes after centrifugation at 800g (Fig. 1BUp , fraction A). It was removed after additional centrifugation at 16 000g, confirming the results of Chiu et al. (Fig. 1BUp , fraction B). Moreover, plasma DNA concentrations derived from the plasma from 7-mL tubes (Fig. 1BUp , fraction D) were identical to the DNA concentrations in cell-free plasma (Fig. 1BUp , fraction B), corroborating our previous results shown in Fig. 1AUp .

From these results, we concluded that the amount of blood collected (i.e., the size of the blood collection tube) affects the presence of contaminating cells in the plasma fraction. Because these cells were present in plasma both from pregnant women (5) and nonpregnant individuals (our results), leukocytes are the most likely explanation for the contaminating cells in the 10-mL blood collection tubes.

In parallel, we questioned whether these contaminating cells in plasma (Fig. 1BUp , fraction A) could be removed after storage at -20 °C. We hypothesized that as a result of the freeze-thaw step, contaminating cells lyse, but their nuclei remain intact and can still be eliminated by high-speed centrifugation. Indeed, high-speed centrifugation of fraction A plasma samples after storage completely eliminated the cellular contamination (Fig. 1BUp , fraction C). The efficiency of elimination was identical to that of high-speed centrifugation before storage (Fig. 1BUp , fraction B).

We conclude that the efficiency of removal of contaminating cellular DNA from plasma is dependent on many preanalytical factors, including centrifugal force, amount of collected blood, and pipetting efficacy. Most importantly, we have shown that irrespective of the protocol used for plasma collection, contaminating cells that remained in the plasma can be removed after storage (-20 °C) of samples. Therefore, frozen plasma collections can be used retrospectively for DNA analysis when subjected to additional centrifugation at 16 000g after thawing.


References

  1. Lo YMD. Fetal DNA in maternal plasma: biology and diagnostic applications. Clin Chem 2000;46:1903-1906.[Abstract/Free Full Text]
  2. Anker P, Mulcahy H, Chen XQ, Stroun M. Detection of circulating tumour DNA in the blood (plasma/serum) of cancer patients. Cancer Metastasis Rev 1999;18:65-73.[CrossRef][ISI][Medline] [Order article via Infotrieve]
  3. Swinkels DW, de Kok JB, Hendriks JCM, Wiegerinck E, Zusterzeel PLM, Steegers EAP. Hemolysis, elevated liver enzymes, and low platelet count (HELLP) syndrome as a complication of preeclampsia in pregnant women increases the amount of cell-free fetal and maternal DNA in maternal plasma and serum. Clin Chem 2002;48:650-653.[Free Full Text]
  4. Sozzi G, Conte D, Mariani L, Lo Vullo S, Roz L, Lombardo C, et al. Analysis of circulating tumor DNA in plasma at diagnosis and during follow-up of lung cancer patients. Cancer Res 2001;61:4675-4678.[Abstract/Free Full Text]
  5. Chiu RWK, Poon LLM, Lau TK, Leung TN, Wong EMC, Lo YMD. Effects of blood-processing protocols on fetal and total DNA quantification in maternal plasma. Clin Chem 2001;47:1607-1613.[Abstract/Free Full Text]



The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
K. Saukkonen, P. Lakkisto, V. Pettila, M. Varpula, S. Karlsson, E. Ruokonen, K. Pulkki, and for the Finnsepsis Study Group
Cell-Free Plasma DNA as a Predictor of Outcome in Severe Sepsis and Septic Shock
Clin. Chem., June 1, 2008; 54(6): 1000 - 1007.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
T. Gotoh, H. Hosoi, T. Iehara, Y. Kuwahara, S. Osone, K. Tsuchiya, M. Ohira, A. Nakagawara, H. Kuroda, and T. Sugimoto
Prediction of MYCN Amplification in Neuroblastoma Using Serum DNA and Real-Time Quantitative Polymerase Chain Reaction
J. Clin. Oncol., August 1, 2005; 23(22): 5205 - 5210.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
S. N. Tamkovich, O. E. Bryzgunova, E. Yu. Rykova, V. I. Permyakova, V. V. Vlassov, and P. P. Laktionov
Circulating Nucleic Acids in Blood of Healthy Male and Female Donors
Clin. Chem., July 1, 2005; 51(7): 1317 - 1319.
[Full Text] [PDF]


Home page
JAMAHome page
Y. Li, E. Di Naro, A. Vitucci, B. Zimmermann, W. Holzgreve, and S. Hahn
Detection of Paternally Inherited Fetal Point Mutations for {beta}-Thalassemia Using Size-Fractionated Cell-Free DNA in Maternal Plasma
JAMA, February 16, 2005; 293(7): 843 - 849.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
C. Stemmer, M. Beau-Faller, E. Pencreac'h, E. Guerin, A. Schneider, D. Jaqmin, E. Quoix, M.-P. Gaub, and P. Oudet
Use of Magnetic Beads for Plasma Cell-free DNA Extraction: Toward Automation of Plasma DNA Analysis for Molecular Diagnostics
Clin. Chem., November 1, 2003; 49(11): 1953 - 1955.
[Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (14)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Swinkels, D. W.
Right arrow Articles by de Kok, J. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Swinkels, D. W.
Right arrow Articles by de Kok, J. B.
Related Collections
Right arrow Molecular Diagnostics and Genetics


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS