Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 49: 652-655, 2003; 10.1373/49.4.652
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Giltay, E. J.
Right arrow Articles by Kromhout, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Giltay, E. J.
Right arrow Articles by Kromhout, D.
Related Collections
Right arrow Laboratory Management
Right arrow General Clinical Chemistry
Right arrow Lipids, Lipoproteins, and Cardiovascular Risk Factors
(Clinical Chemistry. 2003;49:652-655.)
© 2003 American Association for Clinical Chemistry, Inc.


Technical Briefs

High Stability of Markers of Cardiovascular Risk in Blood Samples

Erik J. Giltay1,a, Johanna M. Geleijnse1, Evert G. Schouten1, Martijn B. Katan2 and Daan Kromhout3

1 Division of Human Nutrition & Epidemiology, Wageningen University, 6700 EV Wageningen, The Netherlands

2 Wageningen Center for Food Sciences (M.B.K.), 6700 AN Wageningen, The Netherlands

3 National Institute of Public Health and the Environment, 3720 BA Bilthoven, The Netherlands

aaddress correspondence to this author at: Division of Human Nutrition and Epidemiology, Wageningen University, PO Box 8129, 6700 EV Wageningen, The Netherlands; fax 31-317-483342, e-mail giltay{at}dds.nl

Biomarkers representing long-term risk of coronary heart disease are widely used in epidemiologic research. Procedures for blood sampling and processing need to be efficient and cost-effective to enable large sample sizes for greater statistical power and precision. Transfer of blood samples by mail is less expensive, easier to perform, and less time-consuming than fast courier services or asking patients to attend a central laboratory for blood sampling. This approach may be incorporated into routine practice and may reduce the likelihood of missing data and random error (1)(2) and eliminate intercenter variability. Although the stabilities of many analytes at different temperatures and different time intervals have been reported (3)(4)(5)(6)(7) and some studies have mimicked transportation conditions (2)(8), to our knowledge neither the effects of transfer by a next-working-day mail service nor the effects on the fatty acid (FA) composition are known. We therefore investigated the variability and reliability of risk factors for coronary heart disease in blood samples delivered by a next-working-day mail service, which is available within most Western countries.

We studied 20 healthy volunteers (7 men and 13 women) working at our department, with a mean age of 39 years (range, 23–54 years) and a mean (SD) body mass index of 23.7 (4.8) kg/m2. The study was approved by the Medical Ethical Review Committee of Wageningen University, and written informed consent was obtained from all participants. One set of three tubes of blood was collected in the morning by one trained phlebotomist from each of eight volunteers after an overnight fast: a 10-mL tube containing 18 mg of EDTA, a 4.0-mL tube containing 8 mg of potassium oxalate and 10 mg of sodium fluoride (as antiglycolytic agents), and a 9.5-mL serum separator (SST) tube (Becton Dickinson). To prevent breakage during transport, polyethylene terephthalate tubes were used. All tubes were kept at room temperature until and during transfer. The study was performed during the fall season with a the mean outside temperature ~5 °C (minimum–maximum, -1 to 10 °C).

The baseline set (day 0) was centrifuged (1200g for 10 min) directly, and plasma, serum, and erythrocytes were stored at -80 °C. All SST tubes containing separation gel were also centrifuged directly to form gel barriers between the serum and cells. This enabled us to test whether prolonged contact of serum with a blood clot and hemolysate potentially increases preanalytical variability. The iron chelator EDTA was used to inhibit iron-catalyzed oxidation of polyunsaturated FAs (PUFAs), especially in hemolyzed plasma samples. Blood samples in specially designed plastic envelopes were posted from eight different postboxes covering a radius of ~100 km. After delivery at our laboratory the following day, tubes were processed identically to the baseline set to yield the "day 1" set. This process was repeated to yield the "day 2" set. One posted envelope (of 40) was delayed by 1 day, and two blood samples were lost because the stoppers of the tubes had opened during transport.

All paired samples were assayed in the same run. Standard assays (Roche Diagnostics) were used to determine total cholesterol (cat no. 1489232), HDL-cholesterol (cat. no. 3038661), triglycerides (cat. no. 1488872), glucose (cat. no. 1448668), and ultrasensitive C-reactive protein (CRP-US latex; cat. no. 1972855) and were performed on an automated analyzer (Hitachi 912; Roche Diagnostics). The intra- and interassay CVs for analytic variation (i.e., measurement error) were, respectively, 0.9% and 1.8% for glucose, 0.8% and 1.7% for total cholesterol, 1.3% and 2.6% for HDL, 1.5% and 1.8% for triglycerides, and 1.4% and 5.7% for CRP. The FA composition was measured in serum cholesteryl esters, in EDTA-plasma cholesteryl esters, and in EDTA-erythrocyte membrane phospholipids, according to a modified gas-liquid chromatographic procedure, as described previously (9)(10). Results for FAs were deemed unreliable when there were high unknown peaks in the chromatograms that led to some missing values. FAs were calculated by summing saturated FAs (SAFAs; n = 9), monounsaturated FAs (MUFAs; n = 8), PUFAs (n = 17), n-6 polyunsaturated FAs (n-6 FAs; n = 6), and n-3 polyunsaturated FAs (n-3 FAs; n = 9) with 12–24 carbon atoms (all cis isomers). Because some minor FAs were not assessed, the sums of the mean SAFA, MUFA, and PUFA concentrations added up to ~97%. Intra- and interassay CVs were, on average, 3.3% and 2.9%, respectively, for FAs in cholesteryl esters and somewhat lower for FAs in erythrocyte membrane phospholipids (3.0% and 2.6%, respectively).

Data for day 0 and paired differences are given as the mean (SD). Two types of error may have been introduced: systematic and random error (11). To quantify systematic error, averaged paired differences [mean (SD) as the measure of change at day 1 and 2 vs day 0] and one-sample t-tests (with a test value of 0) were used. To quantity random error, the within-person CV and reliability coefficient were calculated. The CV is 1/{surd}2 times the ratio of the SD of the paired difference to the mean baseline value [1{surd}2 x ({sigma}/mean) x 100%, which covers 68.2% of its variation] (12). The reliability coefficient (i.e., intraclass correlation coefficient with a one-way random effects model with single measure reliability in SPSS) was computed, which reflects the correlation and agreement of test values. These indices allowed comparison of our results with most other reports on variability and reliability.

Shown in Fig. 1 are the plasma values for glucose, lipids, and C-reactive protein. The CV for the paired difference was small (<=3.2% for all), and the reliability was high (>=0.97; P <0.0005 for all) at day 1 vs day 0. A delay of 2 days yielded a somewhat larger CV (<=4.9% for all) and lower reliability (>=0.90% for all). These results were similar for serum values (data not shown). For individual FAs that compose >1%, the mean CV for the paired difference in cholesteryl esters was 3.4% and 2.9% for day 1 and day 2, respectively, and in phospholipids the mean CV was 3.3% and 4.2% for day 1 and day 2, respectively. The CV for the paired difference tended to be higher for minor FAs that constituted <1% of total FAs (see Data Supplement that accompanies the online version of this Technical Brief athttp://www.clinchem.org/content/vol49/issue4/). In both cholesteryl esters and phospholipids, SAFAs were the least reliable and least stable, showing a relative decrease in cholesteryl ester FAs and increase in phospholipid FAs. In both cholesteryl esters and phospholipids, very-long-chain n-6 FAs and n-3 FAs were the most reliable and stable. Eicosapentaenoic acid (C20:5n-3) and docosahexaenoic acid (C22:6n-3), both n-3FAs of marine origin, were highly reliable in all fat fractions (Table 1 ). Although the proportion of n-3 PUFAs was lower in cholesteryl esters than in erythrocyte membrane phospholipids (2.8% vs 9.4%), the variability was larger in cholesteryl esters than in erythrocyte membrane phospholipids (SD, 1.7% vs 1.4%).



View larger version (43K):
[in this window]
[in a new window]
 
Figure 1. Scatter plots showing the effects of delays of 1 and 2 days, respectively, on concentrations of total and HDL-cholesterol, triglycerides, and C-reactive protein in EDTA plasma and glucose in potassium oxalate/sodium fluoride plasma.

LDL-cholesterol values are calculated. C-reactive protein concentrations are shown on a logarithmic scale. {diamond} represent means (or geometric means for C-reactive protein), and error bars represent 95% confidence intervals. Reliability coefficients are calculated for the three time points combined. To transform mmol/L (SI) into mg/L (MGH), divide by 0.0555 for glucose; by 0.0259 for total cholesterol, HDL-cholesterol, and LDL-cholesterol; and by 0.0113 for triglycerides.


View this table:
[in this window]
[in a new window]
 
Table 1. Variability and reliability of FAs in cholesteryl esters and erythrocyte membrane phospholipids after time delays of 1 and 2 days compared with baseline values.1

Mailing blood samples offers a cost-effective approach and enables the study of large numbers of samples (13). In practice, blood specimens can be sampled by phlebotomists at individuals’ homes without the need for strict preanalytic procedures (i.e., direct centrifugation, separation, dispensing, and freezing). This approach ensures lower numbers of missing values, high comparability of groups, and thereby, a high internal validity of the study. We also tested whether direct centrifugation of SST tubes provided extra advantages, which was not the case.

Although the systematic error for some of these analytes (glucose, lipids, and C-reactive protein) was statistically significant, the degree of error was small (~3%), which is in accordance with studies that found a high stability during storage (2)(3)(4)(5)(6)(7)(8). EDTA-plasma cholesteryl esters, serum cholesteryl esters, and phospholipids in EDTA-erythrocyte membranes yielded similar reliability coefficients. Major FAs and their composites were found to be especially reliable, but saturated FAs and minor FAs that constitute <1% of total FAs were less so. The CVs in the present study (~4–5%) were small when balanced first against the intra- and interassay measurement errors (~2–5%) and second against the within-person variability of FAs over time (~9%) (14)(15). Essential n-6 and n-3 PUFAs were especially reliable, both in EDTA plasma and serum and, to a somewhat lesser extent, in erythrocyte-membrane phospholipids. These FAs are not synthesized endogenously, but their circulating concentrations depend on the amounts in foods and reflect dietary intake well (16)(17).

We conclude that after a delay of 1 or 2 days in blood processing, glucose, lipids, C-reactive protein, and individual FAs adequately rank individuals according to baseline values. These analytes are generally stable after next-working-day mail delivery at room temperature; this procedure may therefore be suitable for many epidemiologic investigations. For the FA composition, use of EDTA plasma is the most practical and reliable, whereas for glucose, lipids, and C-reactive protein, plasma and serum are equivalent. Mailing blood samples offers a cost-effective approach for risk factor assessment with acceptable stability and reliability.


Acknowledgments

We thank Janette de Goede, Lucy Okma, and P. van de Bovenkamp (deceased August 11, 2002) for sample collection and laboratory management. The research was funded by the Netherlands Heart Foundation (NHS) as part of a grant for the Alpha Omega Trial (Grant 510.017).


References

  1. Bonini P, Plebani M, Ceriotti F, Rubboli F. Errors in laboratory medicine. Clin Chem 2002;48:691-698.[Abstract/Free Full Text]
  2. Pai JK, Curhan GC, Cannuscio CC, Rifai N, Ridker PM, Rimm EB. Stability of novel plasma markers associated with cardiovascular disease: processing within 36 hours of specimen collection. Clin Chem 2002;48:1781-1784.[Free Full Text]
  3. Ono T, Kitaguchi K, Takehara M, Shiiba M, Hayami K. Serum-constituents analyses: effect of duration and temperature of storage of clotted blood. Clin Chem 1981;27:35-38.[Abstract/Free Full Text]
  4. Rehak NN, Chiang BT. Storage of whole blood: effect of temperature on the measured concentration of analytes in serum. Clin Chem 1988;34:2111-2114.[Abstract/Free Full Text]
  5. Yucel D, Dalva K. Effect of in vitro hemolysis on 25 common biochemical tests. Clin Chem 1992;38:575-577.[Abstract/Free Full Text]
  6. Heins M, Heil W, Withold W. Storage of serum or whole blood samples? Effects of time and temperature on 22 serum analytes. Eur J Clin Chem Clin Biochem 1995;33:231-238.[ISI][Medline] [Order article via Infotrieve]
  7. Narayanan S. The preanalytic phase. An important component of laboratory medicine. Am J Clin Pathol 2000;113:429-452.[CrossRef][ISI][Medline] [Order article via Infotrieve]
  8. Zhang DJ, Elswick RK, Miller WG, Bailey JL. Effect of serum-clot contact time on clinical chemistry laboratory results. Clin Chem 1998;44:1325-1333.[Abstract/Free Full Text]
  9. Wang ST, Peter F. Gas-liquid chromatographic determination of fatty acid composition of cholesteryl esters in human serum using silica Sep-Pak cartridges. J Chromatogr 1983;276:249-256.[ISI][Medline] [Order article via Infotrieve]
  10. Glatz JF, Soffers AE, Katan MB. Fatty acid composition of serum cholesteryl esters and erythrocyte membranes as indicators of linoleic acid intake in man. Am J Clin Nutr 1989;49:269-276.[Abstract/Free Full Text]
  11. Hunter D. Biomedical indicators of dietary intake. Willett WC eds. Nutritional epidemiology, 2nd ed 1998:74-243 Oxford University Press New York. .
  12. Jacobs DR, Jr, Barrett-Connor E. Retest reliability of plasma cholesterol and triglyceride. The Lipid Research Clinics Prevalence Study. Am J Epidemiol 1982;116:878-885.[Abstract/Free Full Text]
  13. Peto R, Collins R, Gray R. Large-scale randomized evidence: large, simple trials and overviews of trials. J Clin Epidemiol 1995;48:23-40.[CrossRef][ISI][Medline] [Order article via Infotrieve]
  14. Ma J, Folsom AR, Eckfeldt JH, Lewis L, Chambless LE. Short- and long-term repeatability of fatty acid composition of human plasma phospholipids and cholesterol esters. The Atherosclerosis Risk in Communities (ARIC) Study Investigators. Am J Clin Nutr 1995;62:572-578.[Abstract/Free Full Text]
  15. Zeleniuch-Jacquotte A, Chajes V, Van Kappel AL, Riboli E, Toniolo P. Reliability of fatty acid composition in human serum phospholipids. Eur J Clin Nutr 2000;54:367-372.[CrossRef][ISI][Medline] [Order article via Infotrieve]
  16. Ma J, Folsom AR, Shahar E, Eckfeldt JH. Plasma fatty acid composition as an indicator of habitual dietary fat intake in middle-aged adults. The Atherosclerosis Risk in Communities (ARIC) Study Investigators. Am J Clin Nutr 1995;62:564-571.[Abstract/Free Full Text]
  17. Andersen LF, Solvoll K, Johansson LR, Salminen I, Aro A, Drevon CA. Evaluation of a food frequency questionnaire with weighed records, fatty acids, and {alpha}-tocopherol in adipose tissue and serum. Am J Epidemiol 1999;150:75-87.[Abstract/Free Full Text]



The following articles in journals at HighWire Press have cited this article:


Home page
Am. J. Clin. Nutr.Home page
W. S Harris
The omega-3 index as a risk factor for coronary heart disease
Am. J. Clinical Nutrition, June 1, 2008; 87(6): 1997S - 2002S.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
M. van Eijsden, M. F. van der Wal, G. Hornstra, and G. J. Bonsel
Can Whole-Blood Samples Be Stored over 24 Hours without Compromising Stability of C-Reactive Protein, Retinol, Ferritin, Folic Acid, and Fatty Acids in Epidemiologic Research?
Clin. Chem., January 1, 2005; 51(1): 230 - 232.
[Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Giltay, E. J.
Right arrow Articles by Kromhout, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Giltay, E. J.
Right arrow Articles by Kromhout, D.
Related Collections
Right arrow Laboratory Management
Right arrow General Clinical Chemistry
Right arrow Lipids, Lipoproteins, and Cardiovascular Risk Factors


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS