Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 50: 755-757, 2004; 10.1373/clinchem.2003.029686
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (11)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Arndt, T.
Right arrow Articles by Heicke, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Arndt, T.
Right arrow Articles by Heicke, B.
Related Collections
Right arrow Lipids, Lipoproteins, and Cardiovascular Risk Factors
Right arrow Endocrinology and Metabolism
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 2004;50:755-757.)
© 2004 American Association for Clinical Chemistry, Inc.


Technical Briefs

Total Plasma Homocysteine Measured by Liquid Chromatography–Tandem Mass Spectrometry with Use of 96-Well Plates

Torsten Arndt1,a, Brunhilde Guessregen1, Axel Hohl1 and Bernd Heicke1

1 Bioscientia GmbH, Konrad-Adenauer-Strasse 17, D-55218 Ingelheim, Germany

aauthor for correspondence: fax 49-6132-781-428, e-mail torsten.arndt{at}bioscientia.de

Increased total plasma or serum homocysteine is regarded as a risk factor for occlusive arterial or venous disease [reviewed in Refs. (1), (2)]. Homocysteine is measured by HPLC (3), immunoassays (4), or liquid chromatography–mass spectrometry (5)(6)(7)(8)(9). We were faced with a large workload of ~200 samples/day, plus high material costs for commercially available immuno- and HPLC assays and laborious sample pretreatment for our HPLC application. We thus wished to establish a high-throughput liquid chromatography–tandem mass spectrometry (LC-MS/MS) method. We aimed at a 96-well plate format for sample pretreatment and autosampling without protein precipitation, centrifugation, or derivatization steps.

We pipetted 50 µL of NaF-plasma, calibrator, or quality-control sample into each well of a 96-well plate (well volume, 2.2-mL) and added to each well 1000 µL of 0.4 µmol/L homocystine-d8 (3,3,3',3',4,4,4',4'-d8-homocystine; Cambridge Isotope Laboratories). The plate was sealed with Parafilm (the tightness was tested with colored solutions) and mixed by vigorous shaking. Of this mixture, 50 µL was transferred to each well of a 96-well plate (well volume, 1.2 mL), diluted with 500 µL of dilute NaOH (50 µL of 6 mol/L NaOH in 500 mL of water), and reduced by the addition of 25 µL of 200 mmol/L dithiothreitol (threo-1,4-mercapto-2,3-butandiol; Aldrich). The plate was sealed (see above), shaken to mix the contents of the wells, left at room temperature for 15 min, and again shaken. We removed the Parafilm and placed the 96-well plate in the autosampler (10 °C) for overnight LC-MS/MS analysis. The sample dilution was 1:241.5 (~1:240 as stated throughout this report).

The LC-MS/MS system consisted of a Surveyor MS pump and Autosampler combined with a triple-quadrupole TSQ Quantum mass spectrometer (Thermo Electron). The autosampler injected 2 µL (~0.008 µL of the native plasma sample) into the system. The mobile phase for the chromatography was a mixture of 2 mL/L acetic acid and methanol (50:50 by volume), the flow rate was 0.2 mL/min, run time was 2 min, and the column was a ThermoHypersil BetaMaxAcid [100 x 2.1 mm (i.d.); 5-µm bead size] with a ThermoHypersil Drop-in Guard Cartridge precolumn (Thermo Electron). The mass spectrometer was operated in the electrospray atmospheric pressure ionization, positive ion, and single-reaction-monitoring mode. The collision energy was 12 eV. Ion transitions m/z 136->90 (homocysteine) and 140->94 (homocysteine-d4), both attributable to a neutral loss of formic acid (6), were assessed. The LC-Quan software (Thermo Electron) was used for calculating the homocysteine/homocysteine-d4 peak-area ratios and quantification of homocysteine. Calibration, quality control, and checks for carryover were performed daily. The details and typical chromatograms obtained by our method are given in the Data Supplement that accompanies the online version of this Technical Brief at http://www.clinchem.org/content/vol50/issue4/.

Passing and Bablok regression (10) was used for unbiased method comparison and linear regression for calculating the calibration functions. The significance of differences between mean and median homocysteine concentrations for different groups was tested by parametric ANOVA (means) and nonparametric Kruskal–Wallis ANOVA (medians). All calculations were done with the Analyze-it software for Microsoft Excel (Analyze-it Software Ltd.). The significance level was set at 95%, or P = 0.05.

Calibration curves were constructed with aqueous homocysteine solutions and with homocysteine added to human plasma. Both procedures were found to be not statistically different (see the online Data Supplement). The validation of our procedure included comparison of results obtained with use of 1.2-mL glass vials and the 96-well plates, optimization of the plasma dilution, and evaluation of the stability of the pretreated plasma samples over 3 days. Passing and Bablok regression (1.2-mL glass vial vs 96-well plate format and 1:240 vs 1:570 plasma dilution), box-plot analysis for testing the effects of sample storage of up to 3 days after sample pretreatment, parametric ANOVA, and nonparametric Kruskal–Wallis ANOVA did not detect significant differences between the corresponding sample pretreatment protocols. This confirmed the comparability of the 96-well plate sample pretreatment with the commonly used 1.2-mL glass vial format, of the 1:570 plasma dilution with the 1:240 plasma dilution protocol, and the stability of the pretreated plasma samples over (at least) 3 days (see the online Data Supplement).

The comparability of our LC-MS/MS method with HPLC (Immundiagnostics) was tested with 187 plasma samples. The Passing and Bablok correlation function (Fig. 1A ) was as follows: LC-MS/MS = 1.12 x HPLC + 0.41 µmol/L. The 95% confidence intervals were 1.075–1.162 for the slope and -0.049 to 0.856 µmol/L for the intercept; the slope was thus statistically significantly different from 1. Bland–Altman analysis (Fig. 1B ) yielded a difference of 1.81 (95% confidence interval, 1.58–2.04). Thus, our LC-MS/MS gave significantly higher (~15–18%) homocysteine results than the HPLC method. Similar results, pointing to the need for a true homocysteine standard (11), were reported by Nelson et al.(8) and, for a comparison between LC-MS/MS and the Abbott IMx assay, by McCann et al.(9).



View larger version (15K):
[in this window]
[in a new window]
 
Figure 1. Passing–Bablok regression analysis (A) and Bland–Altman difference plot (B) for a commercially available HPLC assay and our LC-MS/MS method for total plasma homocysteine.

Significant reductions in material and personnel costs were reported by McCann et al. (9) when they used LC-MS/MS instead of HPLC for homocysteine measurement. This was confirmed by our calculations. Material and personnel costs were diminished by 90% and 60%, respectively. The analysis time was reduced to 2 min/analysis or 400 min/200 samples with our LC-MS/MS method, instead of 12–15 min/analysis or 2400–3000 min/200 samples for HPLC. Earlier reports on homocysteine analysis by LC-MS/MS did not address HPLC column life or LC-MS/MS system maintenance, although both can be important parts of the total analysis costs. Our large sample dilution gave a HPLC column life of ~10 000 analyses and LC-MS/MS maintenance intervals of ~4 months. We consider this an important part of the analysis cost reduction. Most importantly, the 17- to 80-fold greater plasma dilution and the ~37-fold smaller injection volume (~0.008 µL of native plasma by our method) compared with earlier reports (5)(6)(7)(8)(9) minimized the matrix load with each injection and thus the ion suppression, despite our exclusion of protein precipitation. A greater plasma dilution (1:570-fold) did not give increased homocysteine and homocysteine-d4 signals, confirming that there was no ion suppression with the 1:240-fold sample dilution protocol under routine conditions. Such an experiment might be a valuable alternative to the procedure described by Streit et al. (12) when analyte-free samples are not available.

Our method is specific, sensitive, reproducible, and accurate (see Table 1 of the online Data Supplement). A 96-well plate format sample pretreatment in combination with LC-MS/MS for homocysteine analysis has been described previously (7)(9). We consider the combination of this format with a large plasma dilution without deproteinization for high-throughput homocysteine analysis the most important aspect of our application.


Acknowledgments

We thank Dr. Hartmut Kirchherr (Labor Bremen) for scientific discussions.


References

  1. Jacobsen DW. Homocysteine and vitamins in cardiovascular disease. Clin Chem 1998;44:1833-1843.[Abstract/Free Full Text]
  2. Refsum H, Smith AD, Ueland PM, Nexo E, Clarke R, McPartlin J, et al. Facts and recommendations about total homocysteine determinations: an expert opinion. Clin Chem 2004;50:3-32.[Abstract/Free Full Text]
  3. Pastore A, Massoud R, Motti C, Russo AL, Fucci G, Cortese C, et al. Fully automated assay for total homocysteine, cysteine, cysteinylglycine, glutathione, cysteamine, and 2-mercaptopropionylglycine in plasma and urine. Clin Chem 1998;44:825-832.[Abstract/Free Full Text]
  4. Nexo E, Engbaek F, Ueland PM, Westby C, O’Gorman P, Johnston C, et al. Evaluation of novel assays in clinical chemistry. Quantification of plasma total homocysteine. Clin Chem 2000;46:1150-1156.[Abstract/Free Full Text]
  5. Magera MJ, Lacey JM, Casetta B, Rinaldo P. Method for the determination of total homocysteine in plasma and urine by stable isotope dilution and electrospray tandem mass spectrometry. Clin Chem 1999;45:1517-1522.[Abstract/Free Full Text]
  6. Gempel K, Gerbitz K-D, Casetta B, Bauer MF. Rapid determination of total homocysteine in blood spots by liquid chromatography-electrospray ionization-tandem mass spectrometry. Clin Chem 2000;46:122-123.[Free Full Text]
  7. Gillingwater S, McCann S, Turner C, Morris M, Cooper D. Development of a rapid method for the measurement of total homocysteine in plasma using a 96-well plate. Chicago, IL: Proceedings of the 49th ASMS conference on mass spectrometry and allied topics, 2001:1–2..
  8. Nelson BC, Pfeiffer CM, Sniegoski L, Satterfield MB. Development and evaluation of an isotope dilution LC/MS method for the determination of total homocysteine in human plasma. Anal Chem 2003;75:775-784.[Medline] [Order article via Infotrieve]
  9. McCann SJ, Gillingwater S, Keevil BG, Cooper DP, Morris MR. Measurement of total homocysteine in plasma and blood spot using liquid chromatography-tandem mass spectrometry: comparison with the plasma Abbott IMx method. Ann Clin Biochem 2003;40:161-165.[CrossRef][ISI][Medline] [Order article via Infotrieve]
  10. Passing H, Bablok W. A new biometrical procedure for testing the equality of measurements from different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry. J Clin Chem Clin Biochem 1983;21:709-720.[ISI][Medline] [Order article via Infotrieve]
  11. Hanson NQ, Eckfeldt JH, Schwichtenberg K, Aras Ö, Tsai MY. Interlaboratory variation of plasma total homocysteine measurements: results of three successive homocysteine proficiency testing surveys. Clin Chem 2002;48:1539-1545.[Abstract/Free Full Text]
  12. Streit F, Shipkova M, Armstrong VW, Oellerich M. Validation of a rapid and sensitive liquid chromatography–tandem mass spectrometry method for free and total mycophenolic acid. Clin Chem 2003;50:152-159.[Medline] [Order article via Infotrieve]



The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
T. M. Annesley
Methanol-Associated Matrix Effects in Electrospray Ionization Tandem Mass Spectrometry
Clin. Chem., October 1, 2007; 53(10): 1827 - 1834.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
R. Scheidhauer, B. Guessregen, A. Hohl, and T. Arndt
Effects of Prolonged Ambient Storage of Sodium Fluoride/Heparin Specimens on Plasma Homocysteine
Clin. Chem., August 1, 2005; 51(8): 1564 - 1565.
[Full Text] [PDF]


Home page
J. Physiol.Home page
L. Anderson
Candidate-based proteomics in the search for biomarkers of cardiovascular disease
J. Physiol., February 15, 2005; 563(1): 23 - 60.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
M. Kinter
Toward Broader Inclusion of Liquid Chromatography-Mass Spectrometry in the Clinical Laboratory
Clin. Chem., September 1, 2004; 50(9): 1500 - 1502.
[Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (11)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Arndt, T.
Right arrow Articles by Heicke, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Arndt, T.
Right arrow Articles by Heicke, B.
Related Collections
Right arrow Lipids, Lipoproteins, and Cardiovascular Risk Factors
Right arrow Endocrinology and Metabolism
Right arrow Automation and Analytical Techniques


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS