Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 50: 1245-1247, 2004; 10.1373/clinchem.2004.034108
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Data supplement
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Preissner, C. M.
Right arrow Articles by Grebe, S. K.G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Preissner, C. M.
Right arrow Articles by Grebe, S. K.G.
Related Collections
Right arrow Endocrinology and Metabolism
(Clinical Chemistry. 2004;50:1245-1247.)
© 2004 American Association for Clinical Chemistry, Inc.


Technical Briefs

Plastic versus Glass Tubes: Effects on Analytical Performance of Selected Serum and Plasma Hormone Assays

Carol M. Preissner, William M. Reilly, Richard C. Cyr, Dennis J. O’Kane, Ravinder J. Singh and Stefan K.G. Grebea

1 Endocrine Laboratory, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN

aaddress correspondence to this author at: Endocrine Laboratory, Hilton 730C, Mayo Clinic, 200 1st St, SW, Rochester, MN 55905; fax 507-284-9758, e-mail grebs{at}mayo.edu

During the last decade, plastic blood collection tubes have been progressively replacing glass tubes. Plastic tubes are not only less expensive but also safer than glass tubes, because they are less likely to break. Unfortunately, it is frequently difficult or impossible for individual laboratories to obtain comprehensive data on the equivalence of replacement plastic tubes vs their original glass counterparts. This is a particularly important issue for many endocrine assays, especially peptide hormones. These often degrade rapidly and can adsorb to a variety of surfaces (1)(2)(3)(4)(5)(6)(7). Changing from glass to plastic tubes can also be problematic for analytes that are regarded as stable. An example of the latter can be seen in therapeutic drug monitoring, where plastic tubes have been shown to influence the measured concentrations or stabilities of several drugs (8)(9)(10). Similar concerns may apply to low-molecular-weight hormones, such as steroid hormones and biogenic amines. These are increasingly assayed by HPLC, gas chromatography-mass spectrometry, or liquid chromatography-tandem mass spectrometry. It is conceivable that low-molecular-weight organic substances released by plastic tubes could interfere in some of these assays (11) and that small changes that are not detected by immunoassays would change the results of more specific methods. Finally, in certain situations, such as serial monitoring of tumor markers, even minor discrepancies between glass and plastic tubes may gain significance during changeover from one type of collection to the other.

We designed the present study to give a reasonable representation of the range of analytes and analytical methodologies used in our laboratory, with particular emphasis on peptide hormones because of their known instability. We selected the following analytes:

The OHPG assay is an in-house, extracted liquid chromatography-tandem mass spectrometry method with an analytical range of 0.33–330 nmol/L, interassay CV of 2.6–10%, and recoveries of added analyte and dilution linearities of 96–118%. The PTH assay is an in-house intact molecule manual direct chemiluminometric assay that uses a pair of in-house-produced polyclonal antibodies with <30% cross-reactivity with PTH7–34 and no cross-reactivity with more C-terminal fragments. Assay CVs across the analytical range were 5–18%. The other assays are automated direct immunoassays performed on the Beckman-Coulter Access platform (insulin, ß-hCG, cortisol, and hGH), the Nichols Advantage system (ACTH and IGF-I), and the Ortho-Diagnostic Vitros ECi-analyzer (CA-125). All automated assays conformed to the respective manufacturers’ performance specifications, which we verified in house. The ß-hCG assay uses a combination of a mouse monoclonal antibody to the ß-subunit and a polyclonal alkaline phosphatase-linked rabbit anti-total hCG antibody for analyte detection, and goat anti-mouse-antibody-coated paramagnetic beads for separation. The limit of quantification is 0.5 IU/L.

We used a randomized schedule of tube order, generated by our statistics department, for all blood draws to control for any draw-order bias. For all analytes except ACTH, we drew blood from 25 volunteers (age range, 24–57 years; 10 males and 15 females) into serum separator (SS) glass tubes (Becton Dickinson) and into SS plastic tubes manufactured by Becton Dickinson (Vacutainer Tube; designated as type A), Monoject (Sherwood Corvac tube; designated as type B), and Greiner (Greiner Vacuette tube; designated as type C). Except for the insulin hemolysis and ACTH portions of the study (see below), all tubes had the same lot numbers. We froze an aliquot from each tube at –20 °C and kept the remainder at 4 °C for 1 week before also freezing it. All aliquots were thawed and analyzed simultaneously. No particular attention was paid to the order of analysis. In addition, we performed experiments with serum pools of ß-hCG and CA-125, because the majority of the volunteers’ samples contained low analyte concentrations. We prepared 10 pools (>4 mL), each with various concentrations of ß-hCG and CA-125, respectively, that covered the reference interval and included increased concentrations. We distributed each pool equally into four tubes: one glass and three plastic. The tubes were rotated for 30 min at room temperature and then, without any further manipulations, aliquoted and stored as described above. For insulin measurements, we collected samples from an additional 33 donors on a separate occasion into glass and type A plastic tubes. These samples, plus another 46 glass and plastic tube samples (of types A, B, and C) from two different laboratories, were tested for hemolysis of the separated serum by automated hemoglobin assay (Hitachi 747 chemical analyzer hemolysis index function). Significant hemolysis was defined as a serum hemoglobin >100 mg/L because this appears to be the lowest extent of hemolysis that has been shown to lead to falsely low serum insulin determinations (12).

For ACTH, we collected samples from 31 volunteers into siliconized EDTA glass tubes, ordinary EDTA glass tubes, and type A EDTA plastic tubes. The other plastic tube brands were omitted because they had not shown any substantial differences from type A plastic tubes in the other assays (see below). We froze the aliquots immediately or after 4 or 24 h at 4 °C. Again we analyzed all aliquots at the same time.

Continuous data were compared by nonparametric statistics (Fisher paired-sign test) or by ANOVA for repeated measures (ACTH only). Categorical data (significant hemolysis) were compared by {chi}2 analysis. All P values were adjusted for multiple comparisons.

No differences were seen between glass and plastic SS tubes for cortisol, OHPG, hGH, and ß-hCG (see Table 1 in the Data Supplement that accompanies the online version of this Technical Brief at http://www.clinchem.org/content/vol50/issue7/). There were isolated statistically significant differences between glass and plastic SS tubes after 7 days of storage for insulin, IGF-I, and PTH (Table 1 ). These differences were small and clinically insignificant. CA-125 concentrations decreased over time in all sample tubes, indicating a degree of general storage instability. In addition, the CA-125 results differed increasingly over time for all brands of plastic tubes compared with glass tubes. However, these differences were, for the most part, not considered clinically significant. Results obtained with plastic tubes B and C displayed a tendency toward increased variability compared with glass tubes and type A plastic tubes.


View this table:
[in this window]
[in a new window]
 
Table 1. Comparison of glass and plastic tubes for analytes that displayed at least one significant difference.1

Visible hemolysis was observed in several insulin samples drawn into glass tubes, but none was observed in the plastic tubes. Because hemolysis can lead to falsely low insulin measurements (1)(4)(12), this phenomenon was investigated further in a larger sample series. The mean hemoglobin concentrations (67 vs 44 mg/L; median, 50 vs 30 mg/L; P <0.02) and the proportions of samples with significant hemolysis (18% vs 5.3%; P <0.013) were higher in glass tubes than in type A plastic tubes. Type B and C plastic tubes, which had been used in addition to type A tubes in the samples drawn in the two other laboratories, did not differ from type A tubes and also displayed less extensive hemolysis than glass tubes.

ACTH was unstable at 4 °C in all three EDTA sample tubes, but there was no difference between siliconized glass tubes, ordinary glass tubes, and type A plastic tubes (Fig. 1 ).



View larger version (17K):
[in this window]
[in a new window]
 
Figure 1. Stability of ACTH in glass and plastic tubes

Mean ACTH concentrations in EDTA plasma collected in glass tubes ({blacksquare}), plastic tubes ({square}), and siliconized glass tubes (). Plasma was separated immediately (0 h) after the blood draw, or after 4 and 24 h storage of the blood samples at 4 °C (n = 31). Error bars correspond to 95% confidence intervals of the means. There were no statistically significant differences between tube types at any time point. All tube types gave significantly lower readings at 24 h than at 4 h and at baseline (P <0.0001).

We conclude that plastic gel barrier tubes manufactured as Becton Dickinson Vacutainer, Sherwood Corvac Monoject, and Greiner Vacuette are comparable to Becton Dickinson glass SS tubes when used to collect specimens for endocrine testing. There may be minor differences among the three brands, but they are unlikely to be clinically significant. Some analytes, such as ACTH, are inherently unstable, but this is not accentuated by plastic tubes. Conversely, there is also no evidence for the widely held belief (quoted in the specimen requirement instructions of many laboratories) that significant amounts of ACTH adsorb to nonsiliconized glass tubes. To improve ACTH stability in either tube type, it appears likely that further measures, such as addition of potent protease inhibitors, might have to be taken; however, this lies outside the scope of our study.

There are a few minor provisos, however. Storage of serum in plastic gel tubes for long periods may alter CA-125 results, but after 1 week at 4 °C, such changes are usually not clinically significant. There may be some other analytes that could be affected similarly or worse, and stability studies should probably be performed for any analyte that is considered for long-term storage. Another issue is that for three analytes (PTH, IGF-I, and OHPG) our study did not include samples that contained analyte concentrations above the upper limit of the reference interval. It is conceivable, but unlikely, that plastic tubes may behave differently at higher analyte concentrations.

Finally, plastic is the better specimen container to reduce interference from hemolysis in clinical testing, which is particularly relevant to insulin measurements but may affect other tests.


Acknowledgments

We thank Rose Currie and Saralynn Pruett for their help.


References

  1. Hildebrandt W, Kohnert KD, Blech W. Glucagon- and insulin degradation by hemolysate of human erythrocytes. Biomed Biochim Acta 1987;46:557-563.[Web of Science][Medline] [Order article via Infotrieve]
  2. Wu CS, Chen GC. Adsorption of proteins onto glass surfaces and its effect on the intensity of circular dichroism spectra. Anal Biochem 1989;177:178-182.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  3. Patel K. Stability of adrenocorticotropic hormone (ACTH) and pathways of deamidation of asparaginyl residue in hexapeptide segments. Pharm Biotechnol 1993;5:201-220.[Medline] [Order article via Infotrieve]
  4. Sapin R, Ongagna JC, Gasser F, Grucker D. Insulin measurements in haemolysed serum: influence of insulinase inhibitors. Clin Chim Acta 1998;274:111-117.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  5. Evans MJ, Livesey JH, Ellis MJ, Yandle TG. Effect of anticoagulants and storage temperatures on stability of plasma and serum hormones. Clin Biochem 2001;34:107-112.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  6. Quellhorst E. Insulin therapy during peritoneal dialysis: pros and cons of various forms of administration. J Am Soc Nephrol 2002;13:S92-S96.[Abstract/Free Full Text]
  7. Ellis JM, Livesey JH, Evans MJ. Hormone stability in human whole blood. Clin Biochem 2003;36:109-112.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  8. Devine JE. Assessment of the Corvac blood collection tube for drug specimen processing. Ther Drug Monit 1986;8:241-243.[Web of Science][Medline] [Order article via Infotrieve]
  9. Landt M, Wilhite TR, Smith CH. A new plastic evacuated tube with plasma separator. J Clin Lab Anal 1995;9:101-106.[Web of Science][Medline] [Order article via Infotrieve]
  10. Dasgupta A, Yared MA, Wells A. Time-dependent absorption of therapeutic drugs by the gel of the Greiner Vacuette blood collection tube. Ther Drug Monit 2000;22:427-431.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  11. Murthy VV. Unusual interference from primary collection tube in a high-performance liquid chromatography assay of amiodarone. J Clin Lab Anal 1997;11:232-234.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  12. Cantrell JW, Hochholzer JM, Frings CS. Effect of hemolysis on the apparent concentration of insulin in plasma. Clin Chem 1972;18:1423-1425.[Abstract]



The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
S. Wang, V. Ho, A. Roquemore-Goins, and F. A. Smith
Effects of Blood Collection Tubes, including Pediatric Devices, on 16 Common Immunoassays.
Clin. Chem., May 1, 2006; 52(5): 892 - 893.
[Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Data supplement
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Preissner, C. M.
Right arrow Articles by Grebe, S. K.G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Preissner, C. M.
Right arrow Articles by Grebe, S. K.G.
Related Collections
Right arrow Endocrinology and Metabolism


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS