Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 50: 1473-1475, 2004; 10.1373/clinchem.2004.033712
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gijbels, K.
Right arrow Articles by Bossuyt, X.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gijbels, K.
Right arrow Articles by Bossuyt, X.
Related Collections
Right arrow General Clinical Chemistry
Right arrow Proteomics and Protein Markers
(Clinical Chemistry. 2004;50:1473-1475.)
© 2004 American Association for Clinical Chemistry, Inc.


Letters to the Editor

Interference by Gelatin-Based Plasma Substitutes in Capillary Zone Electrophoresis

Koenraad Gijbels1, Johan De Coster2 and Xavier Bossuyt1,a

1 Laboratory Medicine, Immunology, and2 Anesthesia, Leuven University Hospitals, Katholieke Universiteit Leuven, Leuven, Belgium

aAddress correspondence to this author at: Leuven University Hospitals, Laboratory Medicine, Herestraat 49, B-3000 Leuven, Belgium. Fax 32-16-34-79-31; e-mail xavier.bossuyt{at}uz.kuleuven ac.be.


To the Editor:

Analysis of serum proteins by capillary zone electrophoresis (CZE) is used to detect dysproteinemias and monoclonal proteins [reviewed in (1)]. Most interferences in this method are caused by interference with ultraviolet detection [reviewed in (2)]. For example, radio-opaque contrast agents and, to a lesser extent, some antibiotics absorb at 200–214 nm and produce distinct peaks on the electropherogram. A gelatin-based plasma substitute has also been reported to produce an increase in the {gamma}-region in a polyclonal-like way (3). We describe the systematic evaluation of commercially available synthetic colloidal plasma substitutes for their potential to interfere with serum protein analysis by CZE.

WE used the Paragon 2000® (Beckman Coulter) and the Capillarys® (Sebia) CZE systems. The former uses 214 nm and the latter 200 nm as detection wavelength. The Hydrasys/Hyrys/Hydragel® (Sebia) agarose gel electrophoresis (AGE) system was used for comparison.

Synthetic colloidal plasma substitutes can be divided into products based on dextran, starch, or gelatin (4). We studied (a) dextran-based Rheomacrodex® (depolymerized dextran; Mr 40 000; 100 g/L; Pharmalink), (b) starch-based Voluven® [poly(O-2-hydroxyethyl)amylum; Mr 130 000; 60 g/L; Fresenius Kabi] and HAES-steril® (hydroxyethyl amylum; Mr 200 000; 60 g/L; Fresenius Kabi), and (c) gelatin-based Geloplasma® (modified gelatin; mean Mr 30 000; 30 g/L; Fresenius Kabi) and Gelofusine® (modified gelatin; mean Mr 30 000; 40 g/L; B. Braun).

We first evaluated the in vitro effects of the plasma substitutes by mixing equal volumes of the solutions (or phosphate-buffered saline for controls) with normal serum for CZE analysis. The resulting electropherograms are shown in Fig. 1 , A–L; only the gelatin-based plasma substitutes showed clear interference in the electropherograms, although the dextran-based Rheomacrodex produced a small additional peak cathodal to the {gamma}-globulin zone on the Capillarys. Geloplasma induced a broad increase of the {gamma}-globulin fraction extending well into the ß-globulin fraction, and Gelofusine caused a similar increase of the {gamma}-globulin fraction with less interference in the ß-globulin fraction. Quantification corroborated these findings (see Table 1 in the Data Supplement that accompanies the online version of this letter at http://www.clinchem.org/content/vol50/issue8/). These interference patterns were confirmed by electrophoresis of the pure plasma substitute (not shown). Serial dilutions of the gelatin-based substitutes in serum indicated that interference became invisible/nonquantifiable at or below a concentration of 125 mL/L (12.5% by volume; tested on the Paragon 2000 system only).



View larger version (25K):
[in this window]
[in a new window]
 
Figure 1. Effect of colloidal plasma substitutes on electrophoresis.

(A–L), normal serum mixed with phosphate-buffered saline (A and B) or the following plasma substitutes: Rheomacrodex (C and D), Voluven (E and F), HAES-steril (G and H), Geloplasma (I and J), and Gelofusine (K and L). (M–P), serum from a patient before (M and N) and immediately after (O and P) a 1-h (500-mL) infusion of Gelofusine. Electropherograms were obtained with the Paragon 2000 (A, C, E, G, I, K, M, and O) or the Capillarys (B, D, F, H, J, L, N, and P) CZE system. Arrows indicate abnormal peaks.

After receiving approval by our Institutional Review Board and the patients’ informed consent, we evaluated the in vivo effect of Gelofusine on CZE analysis of samples from patients (n = 10) who had received 500-mL infusions of Gelofusine over 1 h for hemodilution during orthopedic surgery by comparing the electropherograms for samples obtained before and immediately after the infusion. The interference was polyclonal-like in the ß-/{gamma}-regions and could not be mistaken for a M-peak (Fig. 1Up ). The increases in the ß-/{gamma}-regions were obvious in all 10 patient samples tested. The median increase in the ß-region was 30% on the Paragon 2000 and 23% on the Capillarys CZE system, whereas there was a small but significant increase in the {alpha}2-region on the Hydrasys AGE system (see Table 1 in the online Data Supplement). The ß-fraction (expressed as a percentage of total serum protein) after infusion exceeded our upper reference limit for this fraction in all patients.

Gelatin-based plasma substitutes are denatured collagens and thus contain complex mixtures of proteins (4). Differences in composition among products might explain the distinct migration patterns seen, as well as the different absorbances at the wavelengths used by the CZE instruments. The proteinaceous nature of these plasma substitutes produces both absorbance in the ultraviolet range and protein dye-binding, thus giving interference in CZE as well as in AGE (but to a much lesser extent, and even more anodal, including interference in the {alpha}2-fraction; see Table 1 in the online Data Supplement). Synthetic plasma substitutes are given mainly at times when serum electrophoresis is rarely indicated, e.g., during emergency fluid resuscitation or for intraoperative hemodilution (4). Moreover, gelatin-based products are rapidly eliminated with an estimated half-life of 2.5 h (5).

In conclusion, gelatin-based plasma expanders may cause interference with serum protein electrophoresis (CZE and to a lesser extent AGE). With CZE these substances typically produce a (polyclonal-like) increase in the ß-/{gamma}-region. To avoid problems, instructions should be given not to collect samples for serum protein electrophoresis during the first hours after infusion of gelatin-based plasma substitutes.


Acknowledgments

We thank J. Vunckx (MCH, Leuven, Belgium) for use of the Capillarys CZE system.


References

  1. Bossuyt X. Separation of serum proteins by automated capillary zone electrophoresis. Clin Chem Lab Med 2003;41:762-772.[CrossRef][ISI][Medline] [Order article via Infotrieve]
  2. Bossuyt X. Interferences in capillary zone electrophoresis of serum proteins. Electrophoresis 2004;25:1485-1487.[CrossRef][ISI][Medline] [Order article via Infotrieve]
  3. Gay-Bellile C, Bengoufa D, Houze P, Le Carrer D, Benlakehal M, Bousquet B, et al. Automated multicapillary electrophoresis for analysis of human serum proteins. Clin Chem 2003;49:1909-1915.[Abstract/Free Full Text]
  4. Roberts JS, Bratton SL. Colloid volume expanders. Drugs 1998;55:621-630.[CrossRef][ISI][Medline] [Order article via Infotrieve]
  5. Mishler JM. Synthetic plasma volume expanders: their pharmacology, safety and clinical efficacy. Clin Haematol 1984;13:75-92.[ISI][Medline] [Order article via Infotrieve]



The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
P. Vermeersch, G. Marien, and X. Bossuyt
A Case of Pseudoparaproteinemia on Capillary Zone Electrophoresis Caused by Geloplasma
Clin. Chem., December 1, 2006; 52(12): 2309 - 2311.
[Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gijbels, K.
Right arrow Articles by Bossuyt, X.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gijbels, K.
Right arrow Articles by Bossuyt, X.
Related Collections
Right arrow General Clinical Chemistry
Right arrow Proteomics and Protein Markers


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS