|
|
||||||||
Proteomics and Protein Markers |
Departments of1
Physiology and 2
Pharmacology and Toxicology, Biocenter Oulu, University of Oulu, Oulu, Finland.
3 Department of Internal Medicine, Kuopio University Hospital, Kuopio, Finland.
4 Department of Pediatrics, Helsinki University Hospital, Helsinki, Finland.
aAddress correspondence to this author at: Department of Physiology, Faculty of Medicine, PO Box 5000, University of Oulu, Oulu, FIN-90014 Finland. Fax 358-8-5375320; e-mail olli.vuolteenaho{at}oulu.fi.
| Abstract |
|---|
|
|
|---|
Methods: The following peptides were prepared with recombinant methods: NT-proANP, NT-proBNP, proBNP1108, and Tyr0-proBNP77108. Fifteen peptides of 1322 amino acids, spanning the sequences of NT-proANP and NT-proBNP, were prepared by solid-phase peptide synthesis. Two immunoassays for NT-proANP and four for NT-proBNP were set up, each with a different epitope specificity. The assays were applied for the measurement of NT-proANP and NT-proBNP in healthy individuals and in patients with acute myocardial infarction. The circulating molecular forms were analyzed by gel-filtration and reversed-phase HPLC.
Results: According to the HPLC analyses, circulating NT-proANP consists mainly of the full-length peptide, with some degradation at both ends. In contrast, circulating NT-proBNP is very heterogeneous. Most immunoreactive NT-proBNP is significantly smaller in size than NT-proBNP176, with truncation at both termini. The smallest fragments can be detected by assays directed at the central part of NT-proBNP only; assays directed at the ends gave 3040% lower values. Despite the difference, the various assays correlated reasonably well with each other (r2 = 0.770.85). In patients with acute myocardial infarction, NT-proANP and NT-proBNP concentrations were 1.82.3 and 4.24.5 times higher than in healthy individuals. The development of heart failure further increased the concentrations.
Conclusions: Molecular heterogeneity of the circulating forms causes a serious risk of preanalytical errors in assays for NT-proBNP and, to a lesser extent, NT-proANP. The development of a sandwich assay for NT-proBNP would be especially challenging. The most robust and reliable assays use antibodies directed at the central portions of NT-proANP or NT-proBNP.
| Introduction |
|---|
|
|
|---|
Both competitive and sandwich assays have been developed for measuring circulating NT-proANP and NT-proBNP; these assays use radioactive, enzymatic, or chemiluminescence labels (11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22). Measured concentrations vary greatly between different assays, especially in the case of NT-proBNP (23)(24). Furthermore, there is some debate about the actual circulating forms. NT-proANP has been reported to circulate in humans almost exclusively as intact NT-proANP198 (25). Alternatively, proANP198 has been found to be broken down into NT-proANP130, NT-proANP3167, and NT-proANP167, which have vasoactive properties (26). Chromatographic studies of proBNP have indicated the presence in human circulation of high-molecular-weight proBNP together with a shorter NT-proBNP peptide (27)(28).
The aims of the present study were to clarify the nature of immunoreactive NT-proANP and NT-proBNP in human blood and to use this information to set up immunoassays, calibrated with full-length peptides, capable of measuring the actual circulating forms of the peptides. We report here the production and purification of recombinant human NT-proANP, NT-proBNP, proBNP1108, and Tyr0-proBNP77108 (Tyr-BNP) as well as the development of six separate competitive immunoassays for NT-proANP and NT-proBNP. Each assay uses a recombinant full-length calibrator but has a different epitope specificity. The circulating forms of immunoreactive NT-proANP and NT-proBNP were characterized by gel-filtration and reversed-phase HPLC (GF-HPLC and RP-HPLC, respectively). Furthermore, five of the assays were used to measure peptide concentrations in healthy persons and in patients with acute myocardial infarction (AMI).
| Materials and Methods |
|---|
|
|
|---|
An overnight culture of Escherichia coli BL21 transformed with recombinant plasmid was diluted 1:100 in 2x YTA (yeast extract, tryptone, NaCl, pH 7) and grown at 37 °C until the absorbance at 660 nm reached 0.6. Isopropyl-1-thio-D-galactopyranoside was added to a final concentration of 0.1 mmol/L, and the culture was incubated for an additional 12 h. The bacterial cells were harvested by centrifugation at 7000g for 10 min at 4 °C, resuspended in phosphate-buffered saline (50 µL for 1 mL of culture), and sonicated. The cell lysate was cleared by centrifugation at 7000g for 15 min. The supernatant was applied to a glutathione-Sepharose 4B column and washed three times with phosphate-buffered saline. The fusion proteins were eluted with 10 mmol/L glutathione in 50 mmol/L Tris-HCl, pH 8.0, and stored in aliquots at 20 °C. The products were analyzed by 12% sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE).
preparation and purification of recombinant NT-PROANP, NT-PROBNP, PROBNP1108, and TYR0-PROBNP77108
Recombinant peptides were released from the glutathione S-transferase (GST) fusion partner by treating with thrombin at room temperature for 1 h (1 U/100 g of protein). The peptides were purified by RP-HPLC on a Vydac C4 HPLC column [25 x 1 cm (i.d.); The Separations Group]. The column was eluted with a linear 40-min gradient from 2050% acetonitrile in aqueous 1 mL/L trifluoroacetic acid. The elution rate was 2 mL/min, and the absorbance at 220 nm was measured to monitor the purity of products. The peak fractions were collected manually. The peptides were quantified based on absorbance at 214 nm by GF-HPLC calibrated with bovine serum albumin. GF-HPLC was performed on a Waters ProteinPak-125 [300 x 3.9 mm (i.d.)] column eluted with 400 mL/L acetonitrile containing 1 mL trifluoroacetic acid at 1 mL/min. The peptides were also separated by 12% SDS-PAGE gel using Tris-tricine electrophoresis buffer. The N-terminal sequences of the peptides were confirmed by 10 cycles of automated Edman degradation in an ABI 477A gas phase sequencer (Applied Biosystems). A QToF I mass spectrometer (Micromass Ltd.) was used to determine the molecular masses of recombinant NT-proANP and NT-proBNP.
peptide synthesis
Synthetic peptides (NT-proANP120, NT-proANP2038, NT-proANP2646, NT-proANP3959, NT-proANP6080, NT-proANP7090, NT-proANP8898, NT-proBNP122, NT-proBNP416, NT-proBNP524, NT-proBNP1029, NT-proBNP2240, NT-proBNP4156, Tyr0-NT-proBNP5774, and Tyr0-NT-proBNP5776) were assembled using Fmoc chemistry with an ABI 433A Peptide Synthesizer (Applied Biosystems).
antisera
The affinity-purified GST/NT-proANP fusion protein was used as such as an immunogen. Before immunization, the peptide immunogens NT-proANP120, NT-proBNP122, NT-proBNP524, NT-proBNP1029, NT-proBNP4156, and Tyr-NT-proBNP5776, were coupled by water-soluble carbodiimide to bovine thyroglobulin or horseshoe crab hemocyanin. Goats received injections at multiple sites in the back (1.0 mg of immunogen emulsified in an equal volume of Freunds complete adjuvant; Difco Laboratories). Boosters of 0.5 mg in Freunds incomplete adjuvant were given two to four times at 2- to 3-week intervals, and the goats were bled 14 days after the injections. The cross-reactivities of antisera were measured by assaying serial dilutions (0.0011 µmol/L) of the following vasoactive peptides: human proANP99126 (ANP128), rat proANP99126 (ANP128), human proBNP77108 (BNP132), human C-type natriuretic peptide, rat adrenomedullin, human endothelin-1, human proBNP1108, human NT-proBNP, and human NT-proANP. The epitope specificities of the antisera were tested using the synthetic peptides described above.
tracer preparation
Recombinant NT-proANP and NT-proBNP (1.5 µg) were radioiodinated with use of 0.5 mCi of Na125I in the presence of 5 µg of chloramine-T in 0.25 mol/L phosphate buffer (pH 7.5) for 15 s, followed by the addition of 10 µg of sodium disulfite. The reaction mixture was purified by gel-filtration chromatography with Sephadex G-25 (Amersham Pharmacia Biotech) followed by RP-HPLC in a Symmetry C18 column [150 x 4.6 mm (i.d.); Waters]. The peptides were eluted with a 30-min gradient of 2050% acetonitrile in aqueous 1 mL/L trifluoroacetic acid at a flow rate of 1 mL/min. Fractions of 1 mL were collected and monitored for radioactivity in a MultiGamma counter (Wallac). The iodinated peptides were usable for at least 5 weeks when stored in aliquots at 20 °C.
assay procedures
RIAs for NT-proANP120 and NT-proANP4679.
Recombinant NT-proANP was used as a calibrator and a tracer in both assays. The following assay buffer was used for all dilutions: 0.04 mol/L sodium hydrogen phosphate, 0.01 mol/L sodium dihydrogen phosphate, 0.1 mol/L NaCl, 1 g/L gelatin, 0.5 mL/L Triton X-100, pH 7.4. Calibrators (606000 pmol/L) or plasma or serum samples were pipetted in duplicates of 25 µL and incubated for 1624 h at 4 °C with 100 µL of antiserum solution (1:20 000 dilution for antiserum to NT-proANP4679 and 1:40 000 dilution for antiserum to NT-proANP120) and 100 µL of tracer solution containing
8000 cpm of the appropriate radioiodinated peptide. Bound and free fractions were separated by precipitation with donkey anti-goat IgG (Scantibodies Laboratory, Inc., and Linco Research, Inc.) in 0.5 mL of 80 g/L polyethylene glycol 6000 containing normal goat serum as a carrier. After centrifugation, the pellet was counted for radioactivity (Clinigamma 1272; Wallac).
RIAs for NT-proBNP122, NT-proBNP1029, and NT-proBNP5776.
Recombinant NT-proBNP was used as the calibrator and tracer in all assays. Calibrators (404000 pmol/L) or plasma or serum samples were pipetted in duplicates of 25 µL and incubated for 1624 h at 4 °C with 100 µL of antiserum solution (final dilutions, 1:10 000 for antiserum to NT-proBNP122 and 1:50 000 for antisera to NT-proBNP1029 and NT-proBNP5776) and 100 µL of tracer solution containing
8000 cpm of radioiodinated peptide. Bound and free fractions were separated with double-antibody precipitation as described above. To be able to measure the low NT-proBNP concentrations in healthy individuals, we used an alternative incubation procedure with increased sensitivity. The tracer was added after incubation for 1624 h, and the calibrators covered the range 161600 pmol/L. Otherwise, the procedure was identical to that described above.
RIAs for NT-proBNP524.
Calibrators (62.51000 pmol/L recombinant NT-proBNP) or plasma or serum samples were pipetted in duplicates of 50 µL and incubated for 1624 h at 4 °C with 100 µL of antiserum solution at a dilution 1:14 000. Tracer solution (100 µL) containing
8000 cpm of iodinated peptide was then added, and the incubation was continued for an additional 1624 h. Bound and free fractions were separated with double-antibody precipitation as described above.
ria validation
Serial dilutions of human plasma and serum were assayed against the NT-proANP and NT-proBNP calibrators to test for parallelism. Assay linearity was analyzed by linear regression analysis with normal human plasma to which the recombinant NT-proANP (1005000 pmol/L) or NT-proBNP (503200 nmol/L; n = 4 each) had been added. The within- and between-assay precision was assessed by measuring 10 replicates of plasma or serum pools with low, medium, and high concentrations of the peptides. The functional sensitivities were analyzed with normal plasma and serum samples as day-to-day CVs <20% (5 replicates on 5 different days). Recoveries were determined by supplementing the normal plasma pool with 500, 2000, or 5000 pmol/L NT-proANP or 200, 800, or 3200 pmol/L NT-proBNP (n = 8 for each).
other RIAS
NT-proANP7998 was measured according to the published RIA method (15). For measurement of the biologically active BNP (proBNP77108), the plasma and serum samples were first extracted with Sep-Pak C18 cartridges (Waters). Calibrators [1100 pmol/L of synthetic human BNP (proBNP77108) purchased from Bachem] or plasma or serum extracts were pipetted in duplicates of 200 µL and incubated for 1624 h at 4 °C with 100 µL of rabbit antiserum against human proBNP77108 at a dilution 1:30 000. Radioiodinated recombinant Tyr0-proBNP77108 (
8000 cpm) was added, and the incubation was continued for an additional 1624 h. The bound and free fractions were separated as described above, with the exception that goat anti-rabbit IgG and normal rabbit serum were used.
rp-hplc and gf-hplc analysis of human plasma and serum
Each human plasma or serum sample (300 µL) was mixed with 200 µL of 1 mL/L trifluoroacetic acid in acetonitrile and cleared by centrifugation at 10 000g for 10 min. The supernatant was passed through a 0.45 µm Millipore filter, and the filtrate was subjected to RP- or GF-HPLC analysis. For RP-HPLC, the sample was applied to a Vydac C4 [150 x 4.6 mm (i.d.)] HPLC column. The sample was eluted with a linear 40-min gradient of 1640% acetonitrile in aqueous 1 mL/L trifluoroacetic acid. The elution rate was 1 mL/min, and 1-mL fractions were collected. For GF-HPLC analysis, the sample was applied to a Protein-Pak 125 GF-HPLC column [300 x 3.9 mm (i.d.); Waters] and eluted with 40% acetonitrile in aqueous 1 mL/L trifluoroacetic acid. The flow rate was 1 mL/min, and 0.5-mL fractions were collected. Fractions were dried in a SpeedVac concentrator and dissolved in 0.5 mL of RIA assay buffer for use in the RIAs.
sample collection
Venous blood samples (serum) from 100 healthy individuals (blood donors; age range, 2065 years; 50 females and 50 males) were collected into Vacutainer Tubes. Blood samples (EDTA plasma) were also obtained from 86 patients with AMI (age range, 3990 years; 19 females and 65 males) (29) at entry to the emergency unit, at 96 h, and/or at discharge from the hospital, so that the total sample count was 206. A few serum samples were also obtained for use in the HPLC studies. The characteristics of study participants are presented in Table 1
. All patients showed ST-segment elevation on electrocardiograms and were treated with the thrombolytic therapy. One week after admission to hospital, the ejection fraction was
40% in 17 patients as determined by echocardiography. In addition, venous blood samples (serum) from five premature infants were used for the initial characterization of the circulating forms of NT-proANP and NT-proBNP because of their extremely high peptide content. Plasma and serum samples were stored at 20 °C until analysis.
|
Informed consent was obtained from all volunteers and patients (or their parents). The investigation conformed with the principles outlined in the Declaration of Helsinki and was approved by the ethics committees of the Universities of Kuopio and Helsinki.
statistics
Our results are reported as the mean (SE). Concentrations below the detection limits are reported as the value for the lowest calibrator. Correlation coefficients were calculated by linear regression analysis. Comparison between two groups was performed using unpaired nonparametric analysis (MannWhitney). Statistical significance was defined as P <0.05.
| Results |
|---|
|
|
|---|
40,
37.5,
41, and
32.5 kDa, respectively).
|
Recombinant human NT-proANP, NT-proBNP, proBNP1108, and Tyr0-proBNP77108 were released from their fusion partners by digestion with thrombin (31). An extra Gly-Ser dipeptide, originating from the cloning vector, was left at the amino terminus of the recombinant peptides. The peptides were further purified from the GST partner, thrombin, and other contaminants by RP-HPLC (Fig. 1
, B and C) with a yield of 0.10.5 mg per liter of original bacterial culture. The sizes of the peptides were
11 kDa for NT-proANP,
8.6 kDa for NT-proBNP,
12 kDa for proBNP1108, and
3.5 kDa for Tyr0-proBNP77108 as detected by SDS-PAGE and GF-HPLC, corresponding to those expected from the amino acid sequences.
The molecular masses of recombinant NT-proANP and NT-proBNP were further ascertained with a mass spectrometer. The obtained masses were 10 767 (8.16) Da for NT-proANP and 8279 (0.43) and 8603 (0.4) Da for NT-proBNP. The identities were also confirmed by N-terminal sequencing, which yielded the unambiguous sequences GSNPMYNAVS for NT-proANP (Fig. 1B
), GSHPLGSPGS for NT-proBNP (Fig. 1C
) and proBNP1108, and GSYSPKMVQG for Tyr0-proBNP77108 (data not shown), consistent with the vector-derived N-terminal Gly-Ser dipeptide followed by the native peptide sequences. The characterized material from a single HPLC purification of NT-proANP or NT-proBNP was used for assay development. These two recombinant peptides are referred to as NT-proANP and NT-proBNP in the text.
production of antisera and development of immunoassays
GST fusion proteins were used as such as immunogens. In addition, we immunized goats with synthetic peptide fragments of NT-proANP and NT-proBNP (NT-proANP120, NT-proBNP122, NT-proBNP524, NT-proBNP1029, NT-proBNP4156, and Tyr0-NT-proBNP5776) coupled to thyroglobulin or hemocyanin. After boosters (2)(3), test bleeds showed 40% binding of the appropriate tracers at final dilutions 1:10 000 to 1:50 000 (Table 2
). However, antiserum raised against NT-proBNP4156 bound to NT-proBNP with a very low titer. The epitope of the GST-NT-proANP antiserum could not be assigned to a simple short sequence, but instead located broadly in the region of amino acids 4679. Thus, it is referred to as antiserum NT-proANP4679. The epitopes of antisera NT-proBNP122, NT-proBNP1029, and NT-proBNP5776 were also tested and were sited in the regions of amino acids 520, 1525, and 5770, respectively.
|
Recombinant NT-proANP and NT-proBNP were radioiodinated at their tyrosine residues and used as tracers in the RIAs. The recombinant peptides were used as calibrators. Typical calibration curves for the NT-proANP4679 and NT-proBNP1029 assays together with dilutions of plasma or serum samples are shown in Fig. 2
. Different amounts of samples from healthy individuals and patients with myocardial infarction displaced in all assays the tracers similarly to the recombinant NT-proANP or NT-proBNP calibrators (all data not shown). Cross-reactivities of the NT-proANP and NT-proBNP antisera relative to other vasoactive peptides human [ANP (proANP99126), rat ANP (proANP99126), human BNP (proBNP77108), C-type natriuretic peptide, rat adrenomedullin, and human endothelin-1] were <0.03%. The NT-proANP antisera did not recognize recombinant human NT-proBNP, and none of the NT-proBNP antisera recognized recombinant human NT-proANP (<0.03%).
|
The NT-proANP assays (NT-proANP120 and NT-proANP4679) were highly linear in the range 100-5000 pmol/L (r2 = 0.999). The NT-proBNP assays (NT-proBNP122, NT-proBNP1029, and NT-proBNP5776) were linear at 1003200 pmol/L (r2 = 0.9996, 0.994, and 0.999, respectively), and the NT-proBNP524 assay was linear at 100800 pmol/L (r2 = 0.995). The detection limits varied between 16 and 63 pmol/L (Table 2
). The functional sensitivities for NT-proANP and NT-proBNP were 100 and 7080 pmol/L, respectively. The median effective concentration (EC50) for the NT-proANP120 assay was 1236 pmol/L, and that for the NT-proANP4679 assay was 389 pmol/L. The EC50 values for the different NT-proBNP assays (NT-proBNP122, NT-proBNP524, NT-proBNP1029, and NT-proBNP5776) were 383, 325, 576, and 520 pmol/L, respectively. The within- and between-assay imprecisions (CVs) were always <15% and <20%, respectively, and usually were markedly better (Table 2
). The recoveries of the analytes varied between 58% and 104%. The analytes were recovered equally well from plasma and serum. The assay characteristics are summarized in Table 2
.
hplc analyses of blood samples
HPLC analyses were performed to characterize the molecular forms of the immunoreactive NT-proANP and NT-proBNP present in human circulation (Figs. 3
and 4
). The HPLC fractions were analyzed with antisera that had epitope specificities in different parts of the peptides.
|
|
A single fairly broad area of immunoreactivity was detected with all of the NT-proANP assays (NT-proANP120, NT-proANP4679, and NT-proANP7998) in the RP-HPLC (Fig. 3A
) and GF-HPLC (Fig. 4A
) analyses of human plasma, peaking at the elution position of the recombinant NT-proANP calibrator. The NT-proANP120 and NT-proANP7998 antisera, however, consistently detected 3050% lower concentrations of immunoreactive NT-proANP in plasma samples compared with the NT-proANP4679 antiserum (Table 3
). The difference was even greater (3070%) with serum. Furthermore, the NT-proANP4679 antiserum detected immunoreactivity in the serum samples eluting after the main peak in GF-HPLC and thus having lower molecular masses. These results indicate that there is some structural heterogeneity in circulating immunoreactive NT-proANP as a result of N- and C-terminal truncation, which can damage the epitopes of terminal antisera.
|
The major peak of immunoreactive NT-proBNP in RP-HPLC analysis of human plasma was detected by all three NT-proBNP assays (NT-proBNP122, NT-proBNP1029, and NT-proBNP5776; Fig. 3C
). The broad peak eluted before the NT-proBNP calibrator, showing that the immunoreactivity was attributable to material that was less hydrophobic, and thus probably smaller in size, than NT-proBNP176. RP-HPLC analysis of serum revealed the presence of even less hydrophobic immunoreactivity, which was recognized with the NT-proBNP1029 antiserum only (Fig. 3D
).
The results from the plasma GF-HPLC analyses were consistent with the RP-HPLC data. NT-proBNP immunoreactivity eluted as a broad region peaking later than the NT-proBNP calibrator, indicating a molecular mass of
68 kDa (Fig. 4C
). The GF-HPLC analysis of immunoreactive NT-proBNP in human serum revealed an even broader peak and indicated the presence of immunoreactive material with a molecular mass as low as 3.5 kDa (Fig. 4D
). Thus, our HPLC data show that circulating immunoreactive NT-proBNP is strongly heterogeneous. NT-proBNP appears to fragment extensively from both ends, and the smallest components can be detected only with antisera directed at the central region of NT-proBNP.
NT-PROANP, NT-PROBNP, and BNP in human plasma or serum
Serum samples from healthy individuals of both sexes (age range, 2065 years) were measured with the different NT-proANP and NT-proBNP immunoassays (Fig. 5
). The mean (SD) concentrations in healthy persons measured with assays specific to NT-proANP120 and NT-proANP4679 were 141 (54) and 255 (95) pmol/L (n = 100), respectively. The corresponding 95% confidence intervals were 130151 and 236274 pmol/L. The mean (SD) concentrations in healthy individuals measured with assays specific to NT-proBNP524, NT-proBNP1029, and NT-proBNP5776 were 86 (41) pmol/L (21 pmol/L below the detection limit; n = 100), 86 (32) pmol/L (all detectable with the assay with delayed addition of tracer), and 59 (37) pmol/L (6 pmol/L below the detection limit for the assay with delayed addition of tracer), respectively. The corresponding 95% confidence intervals were 7894, 7992, and 5166 pmol/L.
|
We used the five new assays, together with an extracted in-house BNP (proBNP77108) assay for reference, to measure natriuretic peptide concentrations in 206 plasma samples obtained from patients after AMI (Table 3
and Fig. 5
). All N-terminal assays revealed significantly increased concentrations in the AMI patients at 96 h (n = 45) compared with healthy individuals (P <0.001). The mean (SD) concentrations of NT-proANP120 and NT-proANP4679 were increased 2.3-fold [141 (5) vs 326 (40) pmol/L] and 1.8-fold [255 (10) vs 467 (38) pmol/L], respectively. The increases in NT-proBNP524, NT-proBNP1029, and NT-proBNP5776 were more pronounced: 4.2-fold [86 (3) vs 364 (41) pmol/L], 4.5-fold [86 (3) vs 391 (61) pmol/L], and 4.5-fold [59 (4) vs 268 (48) pmol/L], respectively. The development of heart failure (ejection fraction
40%) was associated with an additional 1.4- to 1.7-fold increase in NT-proANP120 and NT-proANP4679 concentrations [326 (40) vs 552 (121) pmol/L and 467 (38) vs 658 (88) pmol/L, respectively; n = 16; P <0.05]. The corresponding heart failure-associated increases for NT-proBNP524, NT-proBNP1029, and NT-proBNP5776 were 1.6- to 1.7-fold [364 (41) vs 570 (63), 391 (61) vs 630 (107), and 268 (48) vs 463 (75) pmol/L, respectively; P <0.01]. BNP (proBNP77108) concentrations were measured in 50 patients with AMI at 96 h. The mean BNP concentrations in the absence and presence of heart failure were 33 (7) pmol/L (n = 40) and 61 (14) pmol/L (n = 10), respectively (P = 0.011).
The results obtained with the NT-proANP120 and NT-proANP4679 assays showed significant correlation with each other (r2 = 0.82; Fig. 6A
). The absolute values, however, varied between these two assays, so that the NT-proANP120 assay consistently yielded
30% lower concentrations (Table 3
). The NT-proBNP524, NT-proBNP1029, and NT-proBNP5776 concentrations also correlated significantly with each other (r2 = 0.770.85; Fig. 6
, CE), but again the absolute concentrations varied greatly between the assays. The same decrease (3050%) in the NT-proBNP5776 values compared with the NT-proBNP1029 and the NT-proBNP524 values was detected in the raw plasma samples and in the HPLC data fractions (Table 3
). NT-proBNP (NT-proBNP524, NT-proBNP1029, and NT-proBNP5776) and BNP (proBNP77108) values in AMI patients correlated reasonably well (r2 = 0.690.75; Fig. 6F
; data not shown), revealing the same origin of these analytes. NT-proANP and NT-proBNP concentrations of patients with AMI did not, however, show as good a correlation, particularly on admission (r2 = 0.260.38; Fig. 6B
).
|
| Discussion |
|---|
|
|
|---|
We prepared recombinant plasmids that produce GST fusion proteins of NT-proANP and NT-proBNP to develop homologous assays for the circulating forms of the N-terminal propeptides of ANP and BNP. We also prepared, with the same methods, recombinant proBNP1108 and Tyr0-proBNP77108 to aid assay development. GST fusion proteins can be produced in high amounts, and they are easy to isolate from E. coli lysates by single-step affinity purification (30). The yields were relatively high, although part of the products formed insoluble inclusion bodies. The fusion partner could be easily cleaved from the recombinant target protein by thrombin digestion (31). The pGEX-4T-1 vector contains a cleavage site in the BamHI linker region; therefore, only two additional amino acids are left in the amino terminus of the recombinant protein. We further purified recombinant NT-proANP, NT-proBNP, proBNP1108, and Tyr0-proBNP77108 by RP-HPLC to obtain highly pure peptides for standardization of the RIAs, for tracer preparation, and for calibration of the HPLC analyses. The N-terminal sequencing and mass analyses confirmed that the identity of recombinant NT-proANP corresponded with the full-length GS-NT-proANP198. The mass spectrum of recombinant NT-proBNP, however, revealed two species probably corresponding to GS-NT-proBNP176 and GS-NT-proBNP174. This slight C-terminal truncation has no effect on our quantitative analyses or on the calibration of our assays because our antisera do not bind to this region of the peptide. On the other hand, the presence of the N-terminal Gly-Ser dipeptide so minimally changes the size and hydrophobicity of recombinant proteins that it cannot be detected by the GF-HPLC and RP-HPLC methods used.
We developed two homologous RIAs for NT-proANP and four for NT-proBNP, using high-titer antisera. Each assay uses the appropriate recombinant full-length calibrator but has a different epitope specificity. With these assays the NT-proANP concentration and most of the NT-proBNP concentration can be measured directly in a small amount of plasma or serum without preassay extraction. The analytical ranges of the assays are fairly broad. To our knowledge, this is the first report to describe the production and the use of recombinant NT-proBNP.
Our HPLC data appeared to be consistent with previous finding (25) indicating that NT-proANP circulates in human blood as a single peptide, NT-proANP198. On the other hand, our results were clearly at odds with the previous detection of multiple defined fragments of NT-proANP in human circulation (26). We did, however, find some heterogeneity at the NH2 and COOH termini of NT-proANP, which was evidenced by markedly lower concentrations of immunoreactive NT-proANP in the NT-proANP120 and NT-proANP7998 assays compared with the NT-proANP4679 assay. The difference was particularly clear with serum samples. The terminal fragmentation evidently destroys part of the 120 and the 7998 epitopes. Nevertheless, according to our present results the major part of NT-proANP in human plasma (6070%) is likely intact NT-proANP198.
Previous chromatographic studies have indicated the presence of a high-molecular-mass proBNP peptide (15 kDa) as well as a shorter NT-proBNP peptide (9 kDa) in human plasma (27). It was reported that the 15-kDa material could be detected with antisera specific to BNP and NT-proBNP113 but not with antiserum specific to NT-proBNP6276 (28). The 9-kDa immunoreactive material was recognized by NT-proBNP113 antiserum and less strongly with NT-proBNP6276 antiserum. In the present study we used several antisera with epitopes at the N-terminal, middle, and C-terminal regions of NT-proBNP. We had the advantage of being able to use the same recombinant calibrator and tracer in all of the assays. Our results show that the main form of circulating immunoreactive NT-proBNP can be detected by antisera reactive to either of the termini or to the more central region. It is less hydrophobic and has a smaller molecular mass than NT-proBNP; thus, it probably represents NT-proBNP176-derived peptide(s) truncated at both termini. Our findings that the NT-proBNP122 and NT-proBNP5776 assays detect 2040% less immunoreactivity in this peak compared with the NT-proBNP1029 assay support this conclusion. The NT-proBNP immunoreactivity with a smaller molecular mass observed in RP-HPLC analysis of serum samples was recognized only by antisera directed at NT-proBNP1029. Altogether these findings suggest that circulating NT-proANP and especially NT-proBNP are heterogeneous. NT-proBNP fragments into smaller components in the blood, and very little, if any, of the immunoreactive material is intact NT-proBNP176. The fragmentation is more pronounced in serum than in plasma. In addition, the fragmentation rate detected in this study could be an underestimation because the epitopes of our "terminal" antisera do not reside at the extreme termini of NT-proBNP. We were not able to raise antisera against peptide sequences from the central part of NT-proBNP, which would also bind full-length NT-proBNP; thus, NT-proBNP1029 represents the most central epitope tested in the present study. Although NT-proBNP1029 was the best epitope tested, we cannot rule out the possibility of slight fragmentation even in this portion of NT-proBNP.
With the NT-proANP4679 assay, the range of serum concentrations in healthy individuals was 81571 pmol/L without any significant difference between the sexes (data not shown). The mean (SD) was 255 (95) pmol/L, which is in accordance with previous reports (12)(13)(14)(34). With the NT-proANP120 assay, the mean value was 45% lower, 141 (54) pmol/L. The difference was also seen in the samples from patients with AMI as well as in the HPLC analyses.
The NT-proBNP concentrations in the serum of healthy individuals, as measured with our different assays, ranged from undetectable to 250 pmol/L. We did not detect the previously reported gender divergence (35), although a tendency toward higher values in women could be seen (data not shown). The mean (SD) with the NT-proBNP1029 assay was 86 (32) pmol/L. The NT-proBNP524 assay gave almost identical results [86 (41) pmol/L], but with the NT-proBNP5776 assay, concentrations were considerably lower [59 (37) pmol/L]. Previously reported plasma concentrations in healthy individuals varied greatly, ranging between 1.5 and 159 pmol/L (16)(17)(18)(19)(20)(21)(22)(23). The lowest values were measured with antisera with extreme N-terminal epitopes, and most of the assays required preassay extraction. For example, a fully automated NT-proBNP assay (Roche Diagnostics) uses a pair of antisera raised against NT-proBNP120 and NT-proBNP3950 (19). In the light of our data, attention must be paid to fragmentation of proBNP and to the choice of the epitope to be measured. Because truncation of NT-proANP and NT-proBNP mostly takes place in the circulation and during sample storage, assays with critical epitope requirements, such as those with terminal epitopes and sandwich assays, require careful control of preanalytical errors.
We used our newly developed immunoassays to assay samples from cardiac patients to confirm that the results obtained with the assays apply in both physiologic and pathophysiologic situations. In the patients with AMI, the N-terminal peptide concentrations were significantly higher than in healthy individuals, and the development of heart failure among these patients further increased the concentrations. All of our assays could thus identify the postinfarction patients who had reduced cardiac function and heart failure. Previously reported concentrations of NT-proANP in AMI patients varied between 380 and 2500 pmol/L depending on the assay, on the cardiac status of the patient, and on the day of measurement (33)(34)(36)(37)(38). Typically, NT-proANP has been reported as two- to threefold higher in AMI patients than in healthy persons. Considering that most of our patients belonged to New York Heart Association functional classes 1 and 2, the 1.8- to 2.3-fold increase that we observed is in accordance with the earlier studies. The reported NT-proBNP concentrations in AMI patients have ranged from 96 to 750 pmol/L (7)(35)(39)(40)(41)(42). In our study, NT-proBNP concentrations were 4.1- to 4.5-fold higher in AMI patients and 6.6- to 7.8-fold higher in AMI patients with heart failure than in healthy persons. Despite the different absolute concentrations measured by different assays, a threefold difference in NT-proBNP between healthy individuals and AMI patients has been typical in previous studies (24). However, the absolute concentrations were always higher with assays that included a central antisera. According to our results with AMI samples, the extreme N- and C-terminal antisera of NT-proANP and NT-proBNP give
3040% lower values than the antisera with more central epitopes. On the basis of these results, we conclude again that the assays with stricter epitope requirements are more prone to preanalytical errors caused, e.g., by differences in sampling and storage. Most, if not all, circulating NT-proANP and NT-proBNP is of cardiac origin (2), regardless of the degree of fragmentation. Therefore, an assay capable of picking the largest proportion of the fragments is likely to best reflect the functional status of the heart.
The quantitative results of our assays for N-terminal ANP and BNP can be compared because the assays use equivalent native calibrators. In our study, the mean NT-proANP4679 concentration was approximately threefold higher than the mean NT-proBNP1029 concentration. This resembles the ratios of biologically active ANP and BNP in circulation (1). N-Terminal counterparts of these peptides have longer half-lives (2)(3) and thus higher concentrations in the blood. However, NT-proBNP concentrations in patients with cardiovascular diseases are almost as high as NT-proANP concentrations (2)(24). Because of the low basal concentration of NT-proBNP, the fold change between the samples from healthy individuals and patients is more pronounced with NT-proBNP than with NT-proANP. Accordingly, patients with AMI had 4.5-fold higher concentrations of NT-proBNP1029 than did healthy individuals, whereas the increase in NT-proANP4679 was not more than 1.8-fold. The relatively poor correlation between NT-proANP and NT-proBNP in this pathologic state provides further evidence for the divergent regulation of the two cardiac peptide systems.
In conclusion, we present several immunoassays for NT-proANP and NT-proBNP. All are suitable for direct measurement of the peptides in small volumes of plasma or serum. However, concentrations detected by different assays with various epitope requirements vary because of the heterogeneity of the circulating forms of both NT-proANP and NT-proBNP. Circulating NT-proBNP, in particular, consists of several components of smaller size than intact NT-proBNP. Thus, assays that use antibodies or antisera that are directed at the midregions of NT-proANP or NT-proBNP are the most robust and reliable.
| Acknowledgments |
|---|
| Footnotes |
|---|
| References |
|---|
|
|
|---|
in relation to myocardial infarct size and collagen formation. J Card Fail 2003;9:325-332.[CrossRef][ISI][Medline]
[Order article via Infotrieve]
The following articles in journals at HighWire Press have cited this article:
![]() |
S. Q. Khan, O. Dhillon, D. Kelly, I. B. Squire, J. Struck, P. Quinn, N. G. Morgenthaler, A. Bergmann, J. E. Davies, and L. L. Ng Plasma N-Terminal B-Type Natriuretic Peptide as an Indicator of Long-Term Survival After Acute Myocardial Infarction: Comparison With Plasma Midregional Pro-Atrial Natriuretic Peptide: The LAMP (Leicester Acute Myocardial Infarction Peptide) Study J. Am. Coll. Cardiol., May 13, 2008; 51(19): 1857 - 1864. [Abstract] [Full Text] [PDF] |