Clinical Chemistry 51: 244-247, 2005; 10.1373/clinchem.2004.036301
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (7)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vermeer, H. J.
Right arrow Articles by de Jonge, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vermeer, H. J.
Right arrow Articles by de Jonge, N.
Related Collections
Right arrow Laboratory Management
Right arrow General Clinical Chemistry
Right arrow Automation and Analytical Techniques
(Clinical Chemistry. 2005;51:244-247.)
© 2005 American Association for Clinical Chemistry, Inc.


Technical Briefs

Automated Processing of Serum Indices Used for Interference Detection by the Laboratory Information System

Henricus J. Vermeer, Evert Thomassen and Niels de Jongea

Department of Clinical Chemistry and Hematology, Leyenburg Hospital, PO Box 40551, 2504 LN The Hague, The Netherlands

aauthor for correspondence: fax 31-70-3592191, e-mail n.dejonge{at}leyenburg-ziekenhuis.nl

In this report, we focus on improvements in patient results with respect to interferences in analytical results obtained from a routine chemistry analyzer (Synchron LX20PRO; Beckman Coulter Inc.). Although many authors have reported on improvements in process performance to reduce analytical errors, assay interference by endogenous or exogenous substances is an underrated problem with potential detrimental effects for the patient (1)(2)(3). Four major endogenous compounds that often interfere with most laboratory results are hemoglobin, bilirubin, lipids, and paraproteins (3)(4)(5). In our laboratory, the vast majority of hemolyzed samples (>95%) are attributable to in vitro processes resulting from incorrect sampling procedures or transport (6). Icteric or lipemic samples are indicative of a physiologically, and possibly clinically, important process. Although differentiating between in vivo and in vitro hemolysis is clinically important, extensively hemolyzed samples may be difficult to evaluate (6)(7).

The frequency of interferences in clinical laboratory analyses is very difficult to determine (3). In principle, interferences can be reduced by use of adequately blanked analytical methods (8). Graphical displays of instrument- and analyte-specific interferences have been produced previously (6)(9). The LX20 analyzer has the capability to detect hemolysis, icterus, and lipemia in samples and produces semiquantitative unitless index values for hemoglobin, bilirubin, or Intralipid (so-called serum indices), but these serum index functions are not intended for diagnostic purposes. With increasing amounts of the specific interfering compounds, increasing index values are generated, which are linearly correlated with the amount of interferent.

We assessed the effect of interference by hemolysis, icterus, or lipemia on various analytes, using interference data provided by the manufacturer (Beckman Coulter, Inc.), experimental data from three Dutch hospitals, and our own research. We performed interference studies with serum pools to which interferent solutions were added (up to a maximum of 10% by volume), according to the CERMAB protocol (10). These combined data were used to generate tolerance tables indicating the extent of bias at specific index values. Arriving at a consensus in the field of LX20 serum index decision thresholds was difficult, however. In fact, individual index decision thresholds are in most cases not fully concordant at present. In this context, we have recently begun a harmonization study in The Netherlands of serum index decision thresholds for different analytes assayed on Synchron LX20 systems, and the results of this project will be published elsewhere.

We next developed an algorithm for the detection and processing of clinically or analytically relevant amounts of hemolysis, icterus, and lipemia in assays for 28 analytes, including electrolytes, enzymes, metabolites, and proteins (see Fig. 1 and Table 1 in the Data Supplement available with the online version of this Technical Brief at http://www.clinchem.org/content/vol51/issue1/). Before we developed this algorithm, we defined several initial postulates. The first postulate was that comments should be added to the result only when the amounts of analytically relevant or clinically interferents were significant. We decided to tolerate a deviation of ± 10% from the initial value for most analytes, in concordance with published recommendations (7). However, for some analytes this cutoff point is too high in view of their clinical significance. For this reason, we set the maximum tolerable deviation attributable to interference in assays for sodium and chloride at 5% to avoid wrong interpretation resulting from pseudohyponatremia or pseudohypochloremia (11). The second postulate was that the source of hemolysis initially be considered the result of inappropriate preanalytical conditions (in vitro hemolysis). The third postulate was that the presence of increased lipid concentrations in any patient sample should be detected and that this finding should be communicated to the clinician, followed by lipid removal by centrifugation or treatment with LipoClear® (12). The final postulate was that the workload for laboratorians should be as low as possible.

The developed algorithm has a fully open character and covers different processing layers: detection, automated notification of technicians and physicians, comment reporting, validation, and possible sample rejection. The transparency of the procedure is a great advantage because ongoing research results for interference effects can easily be implemented in the algorithm (e.g., results of the harmonization study). Processing of serum interference is done automatically for selection of chemistries for which interference testing is necessary, for interference detection, for application of decision rules, and for addition of comments to the report (see below). Further (manual) actions depend, of course, on the strategy chosen by the clinical laboratory in agreement with the clinicians.

The algorithm was implemented in two steps: The decision rules and actions to be taken were introduced first, and the algorithm was subsequently implemented in the laboratory information system (LIS), allowing complete automation of both detection and processing. The effectiveness of the algorithm was studied retrospectively.

In our laboratory, the algorithm was written in a specific LIS-dependent language, Mips Internal Site Programming Language (MISPL®). The LIS in use is General Laboratory Information Management System (GLIMS), Ver. 5.5H01 (MIPS). The underlying database is Progress, Ver. 9.1c/d, and the operating system is IBM Unix, Ver. 5.2.0. A graphical representation of the architecture of the algorithm is shown in Fig. 1 . Processing occurs if serum indices indicate significant interference and depends on the extent of analytical error (see Table 2 in the online Data Supplement). If interference is present below a specific critical concentration, the result will be automatically accompanied by a warning comment to alert the clinician. If the index is above this critical concentration, the result is flagged, and the technician is informed by the LIS that the result cannot be reported to the clinician (see Tables 3 and 4 in the online Data Supplement). Principally, rejection of a sample always includes an extra validation step by the technician. An audit trail is generated automatically for every result. To test the performance of the algorithm, we collected laboratory data retrospectively from the LIS for relevant time periods of 12 months before, during, and after introduction of automated detection of serum indices (Table 1 ).



View larger version (8K):
[in this window]
[in a new window]
 
Figure 1. Algorithm for the automated processing of serum indices.

H-index, hemolysis index; I-index, icterus index; L-index, lipemia index.


View this table:
[in this window]
[in a new window]
 
Table 1. Recorded clinically and analytically relevant serum indices causing interference in the analysis of 28 different analyses measured on a clinical chemistry analyzer.

If a patient suffers from intravascular hemolysis, a specific attribute in the LIS can be linked temporarily or permanently to that patient, giving, if desired, specific comments and thereby bypassing the detection and unnecessary flagging for in vitro hemolysis. The occurrence of intravascular hemolysis in a patient is likely if a second ordered sample from that patient shows the same extent of hemolysis.

To determine whether the unacceptable result rate attributable to endogenous interference improved over time, we performed a retrospective analysis to study the effect of the stepwise introduction of systematic detection and the subsequent automatic rule-based algorithm for the actions to be taken on behalf of the clinician (correction of result by adding a comment to the report) or patient (redraw of specimen).

In the year 2000, interference was still detected by visual inspection, and the processing of the finding (e.g., sample rejection, correction, addition of a comment to the report) was a manual action taken by the technician handling the specimen. If the correct action was taken, it was recorded in the LIS. Automated spectrophotometric detection of interference by the chemistry analyzer, as well as decision rules for the systematic, although manual, handling of specimens based on tolerance tables for clinically relevant interference, were introduced in the first half of 2001. In July 2002, the algorithm for completely automated decision-making by the LIS for the processing of serum interference was introduced, and all reported actions were automatically archived in the LIS.

We retrospectively examined the (relative) numbers of samples with clinically relevant serum interferences over three 1-year periods (2000, 2001–2002, and 2002–2003). We traced back the reporting of analytically or clinically relevant serum interference in the LIS for all analytes for each 1-year period. The total number of analyses for each 1-year period for which the algorithm would have been applicable (first two periods) or was applied (last period) and the number of reported incidents of relevant serum interference as recorded in the LIS are shown in Table 1Up .

Introduction of spectrophotometric detection of serum indices and decision rules to be carried out manually increased the detection rate of relevant hemolysis 6.04-fold. After introduction of the algorithm in the LIS, the detection rate for relevant serum interference was 69.37-fold higher than in the first 1-year period. For icteric samples, a large increase in reported interference was observed: whereas the occurrence of icterus in the sample was not reported at all in the first period, during the second 1-year period, 0.05% of specimens were reported as significantly icteric, causing deviations in the assay results. This number was increased 10-fold (0.54%) in the third period.

Interestingly, only one case of lipemia was reported in the first period and none in the second period. Apparently, automated spectrophotometric detection together with written instructions in the second 1-year period did not lead to adequate reporting to the clinician. In the third year, 1012-fold more cases of clinically relevant lipemia were reported than in the first year. It should be pointed out here that the evaluation performed and the observed quality improvement depend on the validity of the automated procedure.

Summarizing, we believe that this algorithm can be used as a blueprint for processing of test results in general. Every test result is now evaluated automatically in real time against predetermined tolerance limits for the extent of interfering substances, and the algorithm is designed as an almost technician-independent method. We encourage cooperation in this project, and copies of the MISPL algorithm and tolerance tables can be obtained free of charge from the corresponding author.


Acknowledgments

We are indebted to G. Steen (Bronovo Hospital, The Hague, The Netherlands), C.H.H. Schoenmakers (Elkerliek Hospital, Helmond, The Netherlands), and J.M.H.M. Punt and P. Agricola (Gooi-Noord Hospital, Blaricum, The Netherlands) for providing interference data from the three Dutch hospitals.


References

  1. Plebani M, Carraro P. Mistakes in a stat laboratory: types and frequency. Clin Chem 1997;43:1348-1351.[Abstract/Free Full Text]
  2. Witte DL, VanNess SA, Angstadt DS, Pennell BJ. Errors, mistakes, blunders, outliers, or unacceptable results: how many?. Clin Chem 1997;43:1352-1356.[Abstract/Free Full Text]
  3. Kroll MH, Elin RJ. Interferences with clinical laboratory analyses. Clin Chem 1994;40:1996-2005.[Abstract]
  4. Behrendt H. Chemistry of erythrocytes 1957:227 Charles C Thomas Springfield, IL. .
  5. Caraway WT. Chemical and diagnostic specificity of laboratory tests. Am J Clin Pathol 1962;37:445-464.[ISI][Medline] [Order article via Infotrieve]
  6. Jay DW, Provasek D. Characterization and mathematical correction of hemolysis interference in selected Hitachi 717 assays. Clin Chem 1993;39:1804-1810.[Abstract]
  7. Sonntag O, Glick MR. Serum-Index und Interferogramm - Ein neuer Weg zur Prüfung und Darstellung von Interferenzen durch Serumchromogene. Lab Med 1989;13:77-81.
  8. Young DS. Effect of drugs on clinical laboratory tests 1990:2200 AACC Washington, DC. .
  9. Glick MR, Ryder KW, Jackson SA. Graphical comparisons of interference in clinical chemistry. Clin Chem 1986;32:470-475.[Abstract/Free Full Text]
  10. Comités Scientifiques des Sociétés, Commission ‘alidation de techniques’: Protocole d’étude de l’influence de la bilirubine, de l’hémoglobine et de la turbidité des spécimens. Ann Biol Clin 1986;44:686-745.
  11. Weisberg LS. Pseudohyponatremia: a reappraisal. Am J Med 1989;86:315-318.[CrossRef][ISI][Medline] [Order article via Infotrieve]
  12. Brady J, O’Leary N. Interference due to lipaemia in routine photometric analysis-survey of an underrated problem. Ann Clin Biochem 1994;31:281-8.



The following articles in journals at HighWire Press have cited this article:


Home page
Ann Clin BiochemHome page
D. Darby and C. Broomhead
Interference with serum indices measurement, but not chemical analysis, on the Roche Modular by Patent Blue V
Ann Clin Biochem, May 1, 2008; 45(3): 289 - 292.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
B. Mensel, U. Wenzel, M. Roser, J. Ludemann, and M. Nauck
Considerably Reduced Centrifugation Time without Increased Hemolysis: Evaluation of the New BD Vacutainer(R) SSTTMII Advance
Clin. Chem., April 1, 2007; 53(4): 794 - 795.
[Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (7)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vermeer, H. J.
Right arrow Articles by de Jonge, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vermeer, H. J.
Right arrow Articles by de Jonge, N.
Related Collections
Right arrow Laboratory Management
Right arrow General Clinical Chemistry
Right arrow Automation and Analytical Techniques


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS