Clinical Chemistry 53: 766-772, 2007. First published March 1, 2007; 10.1373/clinchem.2006.077180
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow All Versions of this Article:
clinchem.2006.077180v1
53/4/766    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (92)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Levey, A. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Levey, A. S.
Related Collections
Right arrow Laboratory Management
Right arrow General Clinical Chemistry
Right arrow Other Areas of Clinical Chemistry
(Clinical Chemistry. 2007;53:766-772.)
© 2007 American Association for Clinical Chemistry, Inc.


Other Areas of Clinical Chemistry

Expressing the Modification of Diet in Renal Disease Study Equation for Estimating Glomerular Filtration Rate with Standardized Serum Creatinine Values

Andrew S. Levey1, Josef Coresh2, Tom Greene3, Jane Marsh2, Lesley A. Stevens1,a, John W. Kusek4, Frederick Van Lente5 for Chronic Kidney Disease Epidemiology Collaboration

1 Division of Nephrology, Tufts-New England Medical Center, Boston, MA.
2 Johns Hopkins Medical Institutions, Baltimore, MD.
3 Department of Quantitative Health Sciences, Cleveland Clinic Foundation, Cleveland, OH.
4 National Institute of Diabetes, Digestive and Kidney Diseases, Bethesda, MD.
5 Department of Clinical Pathology, Cleveland Clinic Foundation, Cleveland, OH.

aAddress correspondence to this author at: Division of Nephrology, Tufts-New England Medical Center, 750 Washington St., Box 391, Boston, MA 02111. Fax 617-636-8329; e-mail lstevens1{at}tufts-nemc.org.


   Abstract
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 
Purpose: We sought to reexpress the 4-variable Modification of Diet in Renal Disease (MDRD) Study equation for estimation of glomerular filtration rate (GFR) using serum creatinine (Scr) standardized to reference methods.

Methods: Serum specimens included creatinine reference materials prepared by the College of American Pathologists (CAP), traceable to primary reference material at the NIST, with assigned values traceable to isotope dilution mass spectrometry (IDMS), a calibration panel prepared by the Cleveland Clinic Research Laboratory (CCRL), and frozen samples from the MDRD Study. Split specimens were measured at the CCRL using the Roche enzymatic and Beckman CX3 kinetic alkaline picrate assays.

Results: Roche enzymatic assay results on CAP samples were comparable to IDMS-assigned values. Beckman CX3 assay results in 2004–2005 were significantly higher than but highly correlated with simultaneous Roche enzymatic assay results (r2 = 0.9994 on 40 CCRL samples) and showed minimal but significant upward drift from Beckman CX3 assay results during the MDRD Study in 1989–1991 (r2 = 0.9987 in 253 samples). Combining these factors, standardized Scr = 0.95 x original MDRD Study Scr. The reexpressed 4-variable MDRD Study equation for Scr (mg/dL) is GFR = 175 x standardized Scr–1.154 x age–0.203 x 1.212 (if black) x 0.742 (if female), and for Scr (µmol/L) is GFR = 30849x standardized Scr–1.154 x age–0.203 x 1.212 (if black) x 0.742 (if female) [GFR in mL · min–1 · (1.73 m2)–1].

Conclusion: When the calibration of Scr methods is traceable to the Scr reference system, GFR should be estimated using the MDRD Study equation that has been reexpressed for standardized Scr.


   Introduction
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 
To facilitate detection, evaluation, and management of chronic kidney disease (CKD),1 guidelines recommend that clinical laboratories compute and report estimated glomerular filtration rate (GFR) using estimating equations such as that derived from the Modification of Diet in Renal Disease (MDRD) Study. Many clinical laboratories have begun this practice (1)(2)(3)(4)(5)(6). Proper use of GFR estimating equations requires a known calibration of the serum creatinine (Scr) assays (7)(8). Calibration to a single standardized Scr based on gold standard methods has been widely recommended (3)(8)(9). The College of American Pathologists (CAP) has prepared fresh-frozen Scr reference materials, traceable to a primary reference material at the NIST, with assigned values based on isotope dilution mass spectrometry (IDMS), for use as trueness controls to verify the traceability of results from routine methods (10)(11).

To date, the relationship of the MDRD Study creatinine assay to standardized creatinine was unknown, although results of smaller studies suggested the CX3 rate Jaffe assay had a small positive bias compared with an IDMS reference method (10)(11). The purposes of this report are to describe procedures for calibrating the Scr assay at the Cleveland Clinic Research Laboratory (CCRL) where the MDRD Study samples were measured and to reexpress the 4-variable (modified) MDRD Study equation (6) for use with standardized Scr.


   Materials and Methods
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 
study design
Chronic Kidney Disease Epidemiology Collaboration is a research group sponsored by the National Institute of Diabetes, Digestive and Kidney Diseases to develop and validate improved estimating equations for GFR by pooling data from research studies and clinical populations. Pooling data requires calibration of Scr assays of collaborating laboratories to creatinine assays currently used at the CCRL. The reference standard method for measurement of Scr, IDMS, is extremely labor intensive, allowing assay of only very few samples. Therefore, we followed recommendations to establish a calibration hierarchy (12). The hierarchy starts with a primary calibrator that materializes the SI units used for expression of creatinine measurements, i.e., the NIST SRM 914a. This primary calibrator is used to directly calibrate the gas chromatography and liquid chromatography (LC) IDMS reference methods. From that point on, all subsequent calibrations or validations of the calibration status of lower-order methods are done via split-sample comparisons at CCRL (Fig. 1 ). First, CAP Creatinine Accuracy Calibration Verification/Linearity Survey LN24 (LN24) samples were used as trueness controls to verify that the calibration of the Roche enzymatic method was traceable to LC-IDMS and correctly implemented in the CCRL. Second, values measured with the Roche enzymatic assay on a calibration panel of 40 native pooled sera prepared by the CCRL were compared with values assigned using the Beckman CX3 assay, the assay that was used during the MDRD Study and is currently in use in the CCRL. Third, with frozen samples from the MDRD Study, the Beckman CX3 assay was adjusted for drift over the past decade. The study was approved by the institutional review boards of all participating institutions.


Figure 1
View larger version (8K):
[in this window]
[in a new window]

 
Figure 1. Steps and results of calibration of the MDRD Study samples to creatinine reference materials.

Stepwise progression by which the Beckman Synchron CX3 (CX3) instrument used at the time of the MDRD Study (CX3 in 1989–1991) was compared with creatinine reference standards measured using IDMS technology. CAP samples with IDMS-assigned values were measured on the Roche enzymatic method and showed equivalence. The CCRL calibration panel was then measured on the Roche instrument and the CX3 machine in 2005. This showed a regression slope of 0.906. Frozen samples from the MDRD study (n = 253) were reassayed in 2004 on the CX3 instrument. This showed a regression slope of 1.046. Multiplication of slopes (1.00 · 0.906 · 1.046) yielded a calibration factor relationship of the original MDRD Study creatinine values to IDMS-traceable reference material of 0.95.

reference samples from cap
CAP 2004 LN24 samples 01 through 07 were prepared from a female-only donor pool, so the creatinine value would be slightly lower than a mixed-sex pool (10)(11)(13). Sample 02 is the base female serum pool. Sample 07 had reagent-grade creatinine added to bring the creatinine to ~352 µmol/L (4 mg/dL). Samples 03 through 06 were prepared by gravimetric admixing of samples 02 and 07. Sample 01 was prepared from sample 02 by gravimetric dilution with 0.01 mol/L phosphate buffered saline [prepared by adding one packet of Sigma P-3813 phosphate-buffered saline, pH 7.4, to 1 L of deionized water (personal communication, Mary Zimmer, January 22, 2007)].

Creatinine concentrations in samples LN24-02 and LN24-07 were value-assigned by the NIST using an LC-IDMS method. NIST-assigned values for samples 02 and 07 were 65.032 and 353.32 µmol/L (0.7390 and 4.0150 mg/dL), respectively. The creatinine values in the other pools were computed based on the known admixtures.

calibration panel
We developed a calibration panel of pooled human sera to establish the calibration relationship between the CX3 (2004) and Roche enzymatic methods across the range of Scr for use in patient samples. The calibration panel was developed at the CCRL from pooled patient sera from the Cleveland Clinic. The calibration panel included 40 reference sera (20 aliquots of 1.0 mL each frozen at –70 °C) pooled from at least 10 mixed-sex donors known to have Scr values covering the full range of 177 to 442 µmol/L (0.5 to 5.0 mg/dL).

Briefly, serum pools were constructed by combining within 2 h of collection excess clear serum obtained from apparently healthy patients and patients with CKD as soon as routine testing was completed. Sera were refrigerated and combined according to the creatinine concentration to achieve a final pool volume of ≥25 mL. The serum pools were mixed by gentle inversion and filtered; their combined creatinine concentrations were measured, and then serum was apportioned into separate 1.0 mL aliquots and frozen at –70 °C. A set of 20 aliquots was thawed and analyzed in triplicate in 3 separate runs on the same day. This process was repeated on a 2nd set of 20 aliquots on a subsequent day. Each sample was analyzed with the Roche enzymatic and CX3 assays after verification that the methods were and remained within internal quality control limits. The runs also included a CAP sample C-02 from the 2003 C mailing (11) prepared according to Clinical and Laboratory Standards Institute 37A (14) as a validated reference material for each 20 pooled specimens. Runs were deemed acceptable if the concentration value for this material remained within 1 SD of the peer method mean.

Assigned values for the calibration panel were based on the Roche enzymatic assay. This method was selected because it is free from most interferences and its calibration is traceable to IDMS (15). In addition, as shown later, this method was verified to recover values assigned by NIST to the CAP trueness controls.

stored samples from the mdrd study
Samples from the MDRD Study were fresh frozen at –70 °C without thawing until 2004. The MDRD Study equation was derived using samples from the 1st baseline visit (B0) during 1989–1991. The 253 samples used in the current study were from the 3rd baseline visit (B3, ~3 months later) and selected sequentially from the serum repository.

creatinine assays at the cleveland clinic foundation research laboratory
The Roche enzymatic assays were performed on a Roche/Hitachi P module automated analyzer with Creatinine Plus enzymatic assay reagents. The enzymatic method is based on the determination of sarcosine after conversion of creatinine with creatininase, creatinase, and sarcosine oxidase. This assay demonstrated CVs of 1.8% and 2.0% at creatinine values of 518 and 78.7 µmol/L (5.86 and 0.89 mg/dL), respectively, in 2004 (n = 194) and 1.1% and 1.6% at creatinine values of 340 and 88.4 µmol/L (3.84 and 1.00 mg/dL), respectively, in 2005 (n = 409).

The Beckman modified kinetic rate alkaline picrate (Jaffe) reaction was performed with the Beckman Synchron CX3 method during the MDRD Study and in 2004. Measurement of the picrate-creatinine complex formation was taken at 520 and 560 nm at 25.6 s after sample introduction. The Beckman CX3 demonstrated CVs of 2.6% and 5.6% at creatinine values of 571 and 78.7 µmol/L (6.46 and 0.89 mg/dL), respectively, in 2004 (n = 390) and 2.4% and 3.8% at creatinine values of 359 and 93.7 µmol/L (4.06 and 1.06 mg/dL), respectively, in 2005 (n = 165).

CAP proficiency test results (n = 25, 2004 C01 to 2005 C10) for these 2 methods at the CCRL demonstrated a mean percentage bias to the peer method target mean of 1.01% (range, 3.46%–5.11%) and 1.79% (range, 2.09%–9.49%) for the Modular P and CX3, respectively. All results were within acceptance criteria. The range of creatinine values for these challenges was 61.9 to 663 µmol/L (0.7 to 7.5 mg/dL).

computations
The mean values of repeated measurements were used for all computations. Linear regression slopes and intercepts were obtained for each comparison of assays. Intercepts that were very small and nonsignificant (P >0.05) were dropped from the regression. The final calibration relationship was obtained by combining point estimates for slopes and intercepts into a single new equation. The final creatinine calibration factor was rounded to 2 significant digits. The SE for the final calibration factor was computed with the delta method (16). Ordinary least-squares regressions were used instead of errors-in-variables regressions because correlations were >0.993. These extremely high correlations indicated the measurement error variance was a very small fraction of the total variance in this calibration setting, at which samples spanned a wide range of creatinine values and assays were averaged across repeated measurements. The final creatinine calibration factor was then incorporated into the constant in the MDRD Study GFR estimating equation.


   Results
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 
standardization of scr assays
Use of CAP sample for verification of traceability of Roche enzymatic assay to IDMS.
Results of assays of the LN24 survey materials on the Roche enzymatic assay are shown in Table 1 . The Roche assay recovered the NIST-assigned values for the LN24 trueness controls, confirming that the Roche method was calibrated to be traceable to IDMS. Assays of the LN24 survey materials in 2004 and 2005 showed nearly identical regression parameters (Fig. 2 ). For all samples combined, the intercept (SE) was –3.01 (0.88) µmol/L [–0.035 (0.01) mg/dL; P = 0.02], and the slope was 1.00 (0.004), r2 = 0.9999. Assay results for samples 01 to 07 were all within 6% of the LN24 survey assigned values [with all values >88 µmol/L (1.0 mg/dL) assaying within 2%]; Statistically, the data suggest that 3.01 µmol/L (0.035 mg/dL) could be subtracted from the Roche enzymatic assay to get the best comparability to NIST-assigned values. Because this difference is small and its inclusion would complicate calculations and the final equation, however, this difference was omitted, and the Roche enzymatic values were used without correction to assign reference values.


View this table:
[in this window]
[in a new window]

 
Table 1. Scr concentration in LN24 survey samples measured by Roche enzymatic assay.1


Figure 2
View larger version (17K):
[in this window]
[in a new window]

 
Figure 2. Roche enzymatic (enz.) assay vs NIST-assigned creatinine values using LC-IDMS on CAP LN24 survey samples.

Linear regression intercept –3.01 µmol/L (–0.035 mg/dL), SE 0.88 µmol/L (0.01 mg/dL); slope 1.00, SE 0.004; r2 = 0.9999).

Standardization of Beckman Synchron CX3 method to Roche enzymatic assay using the CCRL calibration panel.
The Beckman Synchron CX3 and Roche enzymatic methods were highly correlated (Fig. 3 ). The regression of the Roche enzymatic on the Beckman Synchron CX3 method showed a slope (SE) of 0.915 (0.009) and intercept of –2.30 (2.21) µmol/L [–0.026 (0.025) mg/dL]. The P value for the intercept was 0.31. After the small and nonsignificant intercept was dropped, the slope (SE) was 0.906 (0.004; r2 = 0.996).


Figure 3
View larger version (13K):
[in this window]
[in a new window]

 
Figure 3. Roche enzymatic (enz.) vs Beckman Synchron CX3 assays using calibration panel.

(A), intercept set to zero since it was not significant; slope 0.906, SE 0.004, r2 = 0.9994. (B), Bland–Altman plot.

Adjustment of Beckman Synchron CX3 for drift over time by re-assay of MDRD Study samples.
Analysis of 253 frozen MDRD Study samples in 2004 revealed a change over the past decade (Fig. 4 ). The regression showed a slope of 1.037 (0.008) and intercept of 2.53 (2.12) µmol/L [0.029 (0.024) mg/dL], with an intercept P value of 0.23. After the small and nonsignificant intercept value was dropped, slope was 1.046 (0.0024), r2 = 0.9986.


Figure 4
View larger version (14K):
[in this window]
[in a new window]

 
Figure 4. Results for Beckman Synchron CX3 assays performed at the Cleveland Clinic Research Laboratory with MDRD Study samples during 2004 vs during the MDRD Study.

(A), intercept set to zero since it was not significant, slope 1.046, SE 0.002, r2 = 0.9870. (B), Bland–Altman Plot.

computation of the idms-traceable calibration factors and reexpression of the mdrd study equation
The general method for calibrating the CCRL assays to the IDMS assay at NIST is given in Table 2 , equation 1. For all 3 comparisons, intercepts for the regression were taken to be zero, so the final calibration was derived by multiplication of regression slopes (1.0 · 0.906 · 1.046 = 0.95; Fig. 1Up ). The SE of this correction factor, calculated with the delta method and assuming the Roche enzymatic method to be equivalent to the gold standard method, was 0.005. The published MDRD Study equation (Table 2 , equation 2) was reexpressed by substitution of equation 1 for the term Scr (Table 2 , equation 3). Sensitivity analyses retaining intercepts and retaining additional significant digits to the final calibration factors to compute estimated GFR did not show clinically meaningful differences (see the Data Supplement that accompanies the online version of this article at http://www.clinchem.org/content/vol53/issue4).


View this table:
[in this window]
[in a new window]

 
Table 2. Summary of equations for use of standardized Scr assays.1


   Discussion
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 
Variability among clinical laboratories in calibration of Scr assays is an important limitation in the use of GFR estimating equations. Variation in calibration introduces error in GFR estimates, especially at high GFRs (17), and may account in part for the recent reports of widely varying performance of the MDRD Study equation in populations with higher GFRs (18)(19)(20)(21)(22)(23)(24)(25)(26)(27)(28)(29)(30)(31)(32)(33)(34)(35)(36)(37)(38). In particular, the bias at high GFR levels appears greater among studies in which the Scr assay was not calibrated (18). This source of error can be overcome by recalibration of the clinical laboratory creatinine assay to the creatinine assay values of the research laboratory in which the estimating equation was developed. Calibration of clinical laboratory assay values obtained at a specific research laboratory is not practical for widespread implementation of reporting GFR estimates, however.

The National Kidney Disease Education Program (NKDEP) has initiated a creatinine standardization program to improve and normalize Scr results used in estimating equations (8). After creatinine reference materials that are traceable to higher order reference standards are developed, a proficiency testing system will be used to enable ongoing monitoring of calibration among clinical laboratories. This process is expected to be completed by 2008. Reexpression of the MDRD Study equation based on standardized assays will enable implementation of reporting estimated GFR in clinical practice using calibrated Scr assays, thereby overcoming this limitation to the current use of GFR estimating equations.

Using the 2004 CAP LN24-A survey samples, we found the Roche enzymatic assay is comparable to IDMS across a range of Scr values from ~0.5 to 4.0 mg/dL. Note that CAP LN24 survey samples were used as recommended for trueness control, validating the Roche assay, rather than as calibration materials (8). Using the CCRL calibration panel and adjusting the Beckman CX3 assay for drift since the MDRD Study, we calibrated the Scr assay at the MDRD Study laboratory and reexpressed the 4-variable MDRD Study equation for use with creatinine methods traceable to an IDMS reference measurement procedure (8).

Based on the Roche method’s performance in the CAP LN24, creatinine results from the Roche enzymatic method were considered to be traceable to IDMS values. These results have consistently showed the Roche enzymatic method to give results in agreement with IDMS target values. The LN24 samples were verified by the NKDEP Laboratory Working Group to have results that were commutable with those for native clinical samples for the Roche enzymatic creatinine method (personal communication, Greg Miller, December 12, 2006). From a practical perspective, the CAP LN24 is the only material currently available for use as a trueness control and is reasonable to use for a clinical laboratory verification.

These methods may not fully account for measurement error. Our study design includes a 2-step approach to IDMS-traceable calibration of the MDRD Study samples, using combined results from 2 regressions based on split samples rather than results of a single regression based on reassay of original MDRD Study specimens on the Roche enzymatic assay. Nonetheless, our approach is robust. First, the CCRL calibration panel was prepared with rigorous techniques, and the MDRD Study stored samples were collected at the same time as the samples used to develop the equation. Second, several factors make multiplication of the regression slopes a maximum likelihood estimator with high efficiency. The 2 regressions have extremely high correlations (r2 = 0.987 and 0.994), making the loss of efficiency very small. These extremely high correlations over a wide range of creatinine show the linear relationship between the different assays. The SEs for all comparisons performed in this study were minute. Omission of the intercepts is justified by their small magnitude and absence of a statistically or clinically meaningful effect on GFR estimates in sensitivity analyses. The final IDMS-traceable calibration factor of 0.95, relating original MDRD Study Scr measures to standardized creatinine, is our best approximation. Regardless of study design, storage effects on specimens are possible, but the small difference between results on thawed MDRD Study specimens assayed a decade later and CAP samples assayed a year later suggests that any storage effects are small.

The 2003 CAP survey of 5624 clinical laboratories, using a fresh-frozen serum reference material with an assigned value of 79.38 µmol/L (0.902 mg/dL) by IDMS, showed a range of method-dependent bias across laboratories from an underestimate of 5.28 µmol/L (0.06 mg/dL) to an overestimate of 27.28 µmol/L (0.31 mg/dL) (10). This finding suggests that in many laboratories, standardization of Scr assays will lead to decreased reported Scr concentrations, requiring redefinition of the reference range. Without reexpression of estimating equations, lower reported values for Scr would increase GFR estimates. Reexpression of the MDRD Study equation according to the standardized assay enables consistent interpretation of estimated GFR by use of this equation. Use of other GFR estimating equations will require reexpression of the equations with standardized Scr. The effect of standardization of Scr assays on urine creatinine results has not been studied. Thus, it is not possible at this time to determine the effect of standardization on measurements and estimates of creatinine clearance.

Creatinine calibration is only 1 limitation of the current estimating equations. Despite calibration, performance of the MDRD Study equation in populations with higher GFRs appears worse than in populations with lower GFRs. Possible reasons for decreased accuracy include reduced creatinine generation attributable to loss of muscle mass or decreased protein intake, especially in elderly and chronically ill persons, greater measurement error and biological variation in GFR at higher GFR levels, and limitations of generalizing equations developed in populations with CKD to populations without CKD (38). The Chronic Kidney Disease Epidemiology Collaboration is addressing these issues by use of pooled analysis of individual patient data and IDMS-traceable calibration of stored specimens by standardized methods.

NKDEP currently suggests that laboratories should report estimated GFR using the original 4-variable MDRD Study equation (Table 2Up , equation 2), even without IDMS-traceable calibration of Scr assays, recognizing lesser accuracy, especially at levels of GFR >60 mL · min–1 · (1.73 m2)–1 (17). With the availability of appropriate IDMS-traceable calibrator materials from NIST (SRM 967) and trueness control materials from the CAP (LN24 Survey), clinical laboratories can establish and maintain IDMS-traceable calibrated Scr assays and use reexpressed estimating equations, such as the 4-variable MDRD Study equation, to report GFR estimates (Table 2Up , equation 3). Data presented here and in the 2003 CAP survey suggest the Roche enzymatic method meets these criteria. Until improved equations are developed, it may be appropriate to report a specific numeric result only for estimated GFR <60 mL · min–1 · (1.73 m2)–1, as is recommended by current guidelines (4). Although differentiating higher estimates may be useful in research studies, higher values can be reported as ">60 mL · min–1 · (1.73 m2)–1" for clinical reports.


   Acknowledgments
 
We acknowledge assistance from John Eckfeldt, PhD, and Jillian Celi. This study was supported by grants UO1 DK 053869, UO1 DK 067651, and UO1 DK 35073. Presented in abstract form at the Annual Meeting of the American Society of Nephrology in Philadelphia on November 11, 2005. Chronic Kidney Disease Epidemiology Collaboration investigators include the following: from Tufts-New England Medical Center, Andrew S. Levey, MD, Lesley A. Stevens, MD, MS, Christopher H. Schmid, PhD, and Lucy Zhang, MS; from Cleveland Clinic Foundation, Tom Greene, PhD, Frederick VanLente, PhD, and Liang Li, PhD, from John Hopkins University, Josef Coresh, MD, PhD, MHS, Jane Marsh, PhD, Brad Astor, PhD, MPH, and Elizabeth Selvin, PhD MPH; from University of Pennsylvania, Harold I. Feldman, MD, MSCE, and J. Richard Landis, PhD; and from the National Institute of Diabetes and Digestive and Kidney Diseases, John W. Kusek, PhD, Paul W. Eggers, PhD, Thomas H. Hostetter, MD, and Josephine P. Briggs, MD.


   Footnotes
 
1 Nonstandard abbreviations: CKD, chronic kidney disease; GFR, glomerular filtration rate; MDRD, Modification of Diet in Renal Disease; Scr, serum creatinine; CAP, College of American Pathologists; IDMS, isotope dilution mass spectrometry; CCRL, Cleveland Clinic Research Laboratory; LC, liquid chromatography; LN24, Creatinine Accuracy Calibration Verification/Linearity Survey LN24; NKDEP, National Kidney Disease Education Program.


   References
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 

  1. Levey AS, Coresh J, Balk E, Kausz AT, Levin A, Steffes MW, et al. National Kidney Foundation practice guidelines for chronic kidney disease: evaluation, classification, and stratification. Ann Intern Med 2003;139:137-147.[Abstract/Free Full Text]
  2. . National Kidney Foundation. K/DOQI clinical practice guidelines for chronic kidney disease: evaluation, classification, and stratification. Am J Kidney Dis 2002;39(Suppl 1):S1-S266.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  3. Levey AS, Eckardt KU, Tsukamoto Y, Levin A, Coresh J, Rossert J, et al. Definition and classification of chronic kidney disease: a position statement from Kidney Disease: Improving Global Outcomes (KDIGO). Kidney Int 2005;67:2089-2100.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  4. National Kidney Disease Education Program. Creatinine Standardization Program. http://www.nkdep.nih.gov/labprofessionals/index.htm (accessed February 9, 2006)..
  5. Levey AS, Bosch JP, Lewis JB, Greene T, Rogers N, Roth D. A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Ann Intern Med 1999;130:461-470.[Abstract/Free Full Text]
  6. Levey AS, Greene T, Kusek J, Beck G. A simplified equation to predict glomerular filtration rate from serum creatinine [Abstract]. J Am Soc Nephrol 2000;11:155A.
  7. Coresh J, Astor B, McQuillan G, Kusek J, Greene T, Van Lente F, et al. Calibration and random variation of the serum creatinine assay as critical elements of using equations to estimate the glomerular filtration rate. Am J Kidney Dis 2002;39:920-929.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  8. Myers G, Miller W, Coresh J, Fleming J, Greenberg N, Greene T, et al. Recommendations for improving serum creatinine measurement: a report from the laboratory working group of the National Kidney Disease Education Program. Clin Chem 2006;52:5-18.[Abstract/Free Full Text]
  9. Mathew TH, . Australasian Creatinine Consensus Working Group. Chronic kidney disease and automatic reporting of estimated glomerular filtration rate: a position statement. Med J Aust 2005;183:138-141.[Web of Science][Medline] [Order article via Infotrieve]
  10. Miller W, Myers G, Ashwood E, Killeen A, Wang E, Thienpont L, et al. Creatinine measurement: state of the art in accuracy and interlaboratory harmonization. Arch Pathol Lab Med 2005;129:297-304.[Web of Science][Medline] [Order article via Infotrieve]
  11. Miller G, Eckfeldt J. A Creatinine Accuracy Calibration Verification Participant Summary. College of American Pathologists 2005;:1-2.
  12. ISO Guide 17511. In vitro diagnostic medical devices: measurement of quantities in biological samples: metrological traceability of values assigned to calibrators and control materials 2003:1-23 International Organization for Standardization Geneva. .
  13. Miller WG. Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes. Clin Chim Acta 2003;327:25-37.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  14. . NCCLS. Preparation and validation of commutable frozen human serum pools as secondary reference materials for cholesterol measurement procedures: approved guideline 1999:1-8 NCCLS NCCLS document C37-A. Wayne, PA. .
  15. . Roche Diagnostics. Creatinine Plus [Package Insert] :1-4 Roche Diagnostics Indianapolis, IN. .
  16. Cox C. Delta method. Armitage P Colton T eds. Encyclopedia of Biostatistics 1998;Vol. 2:1125-1127 Wiley New York. .
  17. Murthy K, Stevens LA, Stark PC, Levey AS. Variation in serum creatinine assay calibration: a practical application to glomerular filtration rate estimation. Kidney Int 2005;68:1884-1887.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  18. Stevens LA, Levey AS. Clinical implications for estimating equations for glomerular filtration rate [Editorial]. Ann Intern Med 2004;141:959-961.[Free Full Text]
  19. Poggio E, Wang X, Greene T, Van Lente F, Hall P. Performance of the MDRD and Cockcroft-Gault equations in the estimation of glomerular filtration rate in health and in chronic kidney disease. J Am Soc Nephrol 2005;16:459-466.[Abstract/Free Full Text]
  20. Lewis J, Agodoa L, Cheek D, Greene T, Middleton J, O’Connor D, et al. Comparison of cross-sectional renal function measurements in African-Americans with hypertensive nephrosclerosis and of primary formulas to estimate glomerular filtration rate. Am J Kidney Dis 2001;38:744-753.[Web of Science][Medline] [Order article via Infotrieve]
  21. Rule A, Larson T, Bergstralh E, Slezak J, Jacobsen S, Cosio F. Using serum creatinine to estimate glomerular filtration rate: accuracy in good health and in chronic kidney disease. Ann Intern Med 2004;141:929-937.[Abstract/Free Full Text]
  22. Gonwa T, Jennings L, Mai M, Stark P, Levey A, Klintmalm G. Estimation of glomerular filtration rates before and after orthotopic liver transplantation: evaluation of current equations. Liver Trans 2004;10:301-309.[CrossRef]
  23. Froissart M, Rossert J, Jacquot C, Paillard M, Houillier P. Predictive performance of the MDRD and Cockcroft-Gault equations for estimating renal function. J Am Soc Nephrol 2005;16:763-773.[Abstract/Free Full Text]
  24. Hallan S, Asberg A, Lindberg M, Johnsen H. Validation of the Modification of Diet in Renal Disease Formula for estimating GFR with special emphasis on calibration of the serum creatinine assay. Am J Kidney Dis 2004;44:84-93.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  25. Lin J, Knight E, Hogan ML, Singh A. A comparison of prediction equations for estimating glomerular filtration rate in adults without kidney disease. J Am Soc Nephrol 2003;14:2573-2580.[Abstract/Free Full Text]
  26. Bostom A, Kronenberg F, Ritz E. Predictive performance of renal function equations for patients with chronic kidney disease and normal serum creatinine levels. J Am Soc Nephrol 2002;13:2140-2144.[Abstract/Free Full Text]
  27. Zuo L, Ma Y, Wang M, Zhou Y, Xu G, Wang H. Application of glomerular filtration rate estimating equations in Chinese patients with chronic kidney disease. Am J Kidney Dis 2005;45:463-472.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  28. Gaspari F, Ferrari S, Stucchi N, Centemeri E, Carrara F, Pellegrino M, et al. Performance of different prediction equations for estimating renal function in kidney transplantation. Am J Transplant 2004;4:1826-1835.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  29. Lamb E, Webb M, Simpson D, Coakley A, Newman D, O’Riordan S. Estimation of glomerular filtration rate in older patients with chronic renal insufficiency: is the modification of diet in renal disease formula an improvement?. J Am Geriatr Soc 2003;51:1012-1017.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  30. Vervoort G, Willems H, Wetzels J. Assessment of glomerular filtration rate in healthy subjects and normoalbuminuric diabetic patients: validity of a new (MDRD) prediction equation. Nephrol Dial Transplant 2002;17:1909-1913.[Abstract/Free Full Text]
  31. Skluzacek P, Szewc R, Nolan C, Riley D, Lee S, Pergola P. Prediction of GFR in liver transplant candidates. Am J Kidney Dis 2003;42:1169-1176.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  32. Ibrahim H, Mondress M, Tello A, Fan Y, Koopmeiners J, Thomas W. An alternative formula to the Cockcroft-Gault and the Modification of Diet in Renal Diseases formulas in predicting GFR in individuals with type 1 diabetes. J Am Soc Nephrol 2005;16:1051-1060.[Abstract/Free Full Text]
  33. Rigalleau V, Lasseur C, Perlemoine C, Barthe N, Raffaitin C, Liu C, et al. Estimation of glomerular filtration rate in diabetic subjects: Cockcroft formula or Modification of Diet in Renal Disease study equation?. Diabetes Care 2005;28:838-843.[Abstract/Free Full Text]
  34. Poge U, Gerhardt T, Palmedo H, Klehr H-U, Sauerbruch T, Woitas RP. MDRD equations for estimation of GFR in renal transplant recipients. Am J Transplant 2005;5:1306-1311.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  35. Grubb A, Bjork J, Lindstrom V, Sterner G, Bondesson P, Nyman U. A cystatin C-based formula without anthropometric variables estimates glomerular filtration rate better than creatinine clearance using the Cockcroft-Gault formula. Scand J Clin Lab Invest 2005;65:153-162.[Web of Science][Medline] [Order article via Infotrieve]
  36. Fehrman-Ekholm I, Skeppholm L. Renal function in the elderly (>70 years old) measured by means of iohexol clearance, serum creatinine, serum urea and estimated clearance. Scand J Clin Lab Invest 2005;38:73-77.
  37. Coresh J, Stevens LA. Kidney function estimating equations: where do we stand?. Curr Opin Nephrol Hyper 2006;15:276-284.[Web of Science][Medline] [Order article via Infotrieve]
  38. Stevens LA, Coresh J, Greene T, Levey AS. Assessing kidney function: measured and estimated glomerular filtration rate. New Eng J Med 2006;354:2473-2483.[Free Full Text]



The following articles in journals at HighWire Press have cited this article:


Home page
Am J Clin PatholHome page
N. L. Korpi-Steiner, E. E. Williamson, and B. S. Karon
Comparison of Three Whole Blood Creatinine Methods for Estimation of Glomerular Filtration Rate Before Radiographic Contrast Administration
Am J Clin Pathol, December 1, 2009; 132(6): 920 - 926.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
A. Haase-Fielitz, R. Bellomo, P. Devarajan, M. Bennett, D. Story, G. Matalanis, U. Frei, D. Dragun, and M. Haase
The predictive performance of plasma neutrophil gelatinase-associated lipocalin (NGAL) increases with grade of acute kidney injury
Nephrol. Dial. Transplant., November 1, 2009; 24(11): 3349 - 3354.
[Abstract] [Full Text] [PDF]


Home page
Ann Clin BiochemHome page
D P Bathia, D R Carless, K Viswanathan, A S Hall, and J H Barth
Serum 99th centile values for two heart-type fatty acid binding protein assays
Ann Clin Biochem, November 1, 2009; 46(6): 464 - 467.
[Abstract] [Full Text] [PDF]


Home page
Circ Cardiovasc ImagingHome page
M. H. Al-Mallah, R. Hachamovitch, S. Dorbala, and M. F. Di Carli
Incremental Prognostic Value of Myocardial Perfusion Imaging in Patients Referred to Stress Single-Photon Emission Computed Tomography With Renal Dysfunction
Circ Cardiovasc Imaging, November 1, 2009; 2(6): 429 - 436.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
D. Tsinalis and G. T. Thiel
An easy to calculate equation to estimate GFR based on inulin clearance
Nephrol. Dial. Transplant., October 1, 2009; 24(10): 3055 - 3061.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
C. Widera, R. Horn-Wichmann, T. Kempf, K. Bethmann, B. Fiedler, S. Sharma, R. Lichtinghagen, H. Leitolf, B. Ivandic, H. A. Katus, et al.
Circulating Concentrations of Follistatin-Like 1 in Healthy Individuals and Patients with Acute Coronary Syndrome as Assessed by an Immunoluminometric Sandwich Assay
Clin. Chem., October 1, 2009; 55(10): 1794 - 1800.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Soc. Nephrol.Home page
B. C. Astor, A. S. Levey, L. A. Stevens, F. Van Lente, E. Selvin, and J. Coresh
Method of Glomerular Filtration Rate Estimation Affects Prediction of Mortality Risk
J. Am. Soc. Nephrol., October 1, 2009; 20(10): 2214 - 2222.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
L. A. Stevens, C. H. Schmid, Y. Zhang, J. Coresh, J. Manzi, R. Landis, O. Bakoush, G. Contreras, S. Genuth, G. B. Klintmalm, et al.
Development and validation of GFR-estimating equations using diabetes, transplant and weight
Nephrol. Dial. Transplant., September 30, 2009; (2009) gfp510v1.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
K. E. Ensrud, B. C. Taylor, M. L. Paudel, J. A. Cauley, P. M. Cawthon, S. R. Cummings, H. A. Fink, E. Barrett-Connor, J. M. Zmuda, J. M. Shikany, et al.
Serum 25-Hydroxyvitamin D Levels and Rate of Hip Bone Loss in Older Men
J. Clin. Endocrinol. Metab., August 1, 2009; 94(8): 2773 - 2780.
[Abstract] [Full Text] [PDF]


Home page
Antimicrob. Agents Chemother.Home page
N. Perrottet, C. Csajka, M. Pascual, O. Manuel, F. Lamoth, P. Meylan, J. D. Aubert, J. P. Venetz, P. Soccal, L. A. Decosterd, et al.
Population Pharmacokinetics of Ganciclovir in Solid-Organ Transplant Recipients Receiving Oral Valganciclovir
Antimicrob. Agents Chemother., July 1, 2009; 53(7): 3017 - 3023.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
P. O. Collinson, O. Clifford-Mobley, D. Gaze, F. Boa, and R. Senior
Assay Imprecision and 99th-Percentile Reference Value of a High-Sensitivity Cardiac Troponin I Assay
Clin. Chem., July 1, 2009; 55(7): 1433 - 1434.
[Full Text] [PDF]


Home page
J. Am. Soc. Nephrol.Home page
A. Haase-Fielitz, M. Haase, R. Bellomo, G. Lambert, G. Matalanis, D. Story, L. Doolan, B. Buxton, G. Gutteridge, F. C. Luft, et al.
Decreased Catecholamine Degradation Associates with Shock and Kidney Injury after Cardiac Surgery
J. Am. Soc. Nephrol., June 1, 2009; 20(6): 1393 - 1403.
[Abstract] [Full Text] [PDF]


Home page
ANN INTERN MEDHome page
A. S. Levey, L. A. Stevens, C. H. Schmid, Y. Zhang, A. F. Castro III, H. I. Feldman, J. W. Kusek, P. Eggers, F. Van Lente, T. Greene, et al.
A New Equation to Estimate Glomerular Filtration Rate
Ann Intern Med, May 5, 2009; 150(9): 604 - 612.
[Abstract] [Full Text] [PDF]


Home page
CJASNHome page
R. J. Glassock and C. G. Winearls
eGFR: Readjusting Its Rating
Clin. J. Am. Soc. Nephrol., May 1, 2009; 4(5): 867 - 869.
[Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
R. Xu, L. Zhang, P. Zhang, F. Wang, L. Zuo, and H. Wang
Comparison of the prevalence of chronic kidney disease among different ethnicities: Beijing CKD survey and American NHANES
Nephrol. Dial. Transplant., April 1, 2009; 24(4): 1220 - 1226.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
F. Pizzarelli, F. Lauretani, S. Bandinelli, G. B. Windham, A. M. Corsi, S. V. Giannelli, L. Ferrucci, and J. M. Guralnik
Predictivity of survival according to different equations for estimating renal function in community-dwelling elderly subjects
Nephrol. Dial. Transplant., April 1, 2009; 24(4): 1197 - 1205.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
J. R. Delanghe
How to estimate GFR in children
Nephrol. Dial. Transplant., March 1, 2009; 24(3): 714 - 716.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
C. M. Cobbaert, H. Baadenhuijsen, and C. W. Weykamp
Prime Time for Enzymatic Creatinine Methods in Pediatrics
Clin. Chem., March 1, 2009; 55(3): 549 - 558.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
W. G. Miller
Estimating Equations for Glomerular Filtration Rate in Children: Laboratory Considerations
Clin. Chem., March 1, 2009; 55(3): 402 - 403.
[Full Text] [PDF]


Home page
Am J EpidemiolHome page
N. A. Zakai, L. A. McClure, R. Prineas, G. Howard, W. McClellan, C. E. Holmes, B. B. Newsome, D. G. Warnock, P. Audhya, and M. Cushman
Correlates of Anemia in American Blacks and Whites: The REGARDS Renal Ancillary Study
Am. J. Epidemiol., February 1, 2009; 169(3): 355 - 364.
[Abstract] [Full Text] [PDF]


Home page
HypertensionHome page
H. Kobori, A. B. Alper Jr, R. Shenava, A. Katsurada, T. Saito, N. Ohashi, M. Urushihara, K. Miyata, R. Satou, L. L. Hamm, et al.
Urinary Angiotensinogen as a Novel Biomarker of the Intrarenal Renin-Angiotensin System Status in Hypertensive Patients
Hypertension, February 1, 2009; 53(2): 344 - 350.
[Abstract] [Full Text] [PDF]


Home page
Annals of Clinical & Laboratory ScienceHome page
S. Badiou, S. Bariolet, A.-M. Dupuy, A. Sultan, A. Avignon, and J.-P. Cristol
A New DiaSys Colorimetric Assay for Plasma Homocysteine: Application in Diabetic Patients
Ann. Clin. Lab. Sci., January 1, 2009; 39(3): 233 - 240.
[Abstract] [Full Text] [PDF]


Home page
Age AgeingHome page
G. Lippi, G. Targher, G. L. Salvagno, M. Montagnana, and G. C. Guidi
Detecting of chronic kidney disease in older people by the MDRD and MCQ formulas
Age Ageing, November 1, 2008; 37(6): 722 - 722.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. G. Shellock and A. Spinazzi
MRI Safety Update 2008: Part 1, MRI Contrast Agents and Nephrogenic Systemic Fibrosis
Am. J. Roentgenol., October 1, 2008; 191(4): 1129 - 1139.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
E. Crowe, D. Halpin, P. Stevens, and on behalf of the Guideline Development Group
Early identification and management of chronic kidney disease: summary of NICE guidance
BMJ, September 29, 2008; 337(sep29_1): a1530 - a1530.
[Full Text]


Home page
Nephrol Dial TransplantHome page
M. Chonchol, G. Lippi, M. Montagnana, M. Muggeo, and G. Targher
Association of inflammation with anaemia in patients with chronic kidney disease not requiring chronic dialysis
Nephrol. Dial. Transplant., September 1, 2008; 23(9): 2879 - 2883.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
A. Stavroulopoulos, O. Sahota, I. Qamar, C. J. Porter, M. J.D. Cassidy, and S. D. Roe
Presence of chronic kidney disease stages 3 and 4 in patients with low trauma fracture
Nephrol. Dial. Transplant., August 1, 2008; 23(8): 2710 - 2711.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
H. E. van Deventer, J. A. George, J. E. Paiker, P. J. Becker, and I. J. Katz
Estimating Glomerular Filtration Rate in Black South Africans by Use of the Modification of Diet in Renal Disease and Cockcroft-Gault Equations
Clin. Chem., July 1, 2008; 54(7): 1197 - 1202.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
J. Coresh, L. A. Stevens, and A. S. Levey
Chronic kidney disease is common: What do we do next?
Nephrol. Dial. Transplant., April 1, 2008; 23(4): 1122 - 1125.
[Full Text] [PDF]


Home page
CJASNHome page
B. G. Jaar, R. Khatib, L. Plantinga, L. E. Boulware, and N. R. Powe
Principles of Screening for Chronic Kidney Disease
Clin. J. Am. Soc. Nephrol., March 1, 2008; 3(2): 601 - 609.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
F. Ceriotti, J. C. Boyd, G. Klein, J. Henny, J. Queralto, V. Kairisto, M. Panteghini, and on behalf of the IFCC Committee on Reference Inter
Reference Intervals for Serum Creatinine Concentrations: Assessment of Available Data for Global Application
Clin. Chem., March 1, 2008; 54(3): 559 - 566.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
P. Delanaye, E. Cavalier, and J. M. Krzesinski
Determining Prevalence of Chronic Kidney Disease Using Estimated Glomerular Filtration Rate
JAMA, February 13, 2008; 299(6): 631 - 631.
[Full Text] [PDF]


Home page
JAMAHome page
J. Coresh, L. A. Stevens, and A. S. Levey
Determining Prevalence of Chronic Kidney Disease Using Estimated Glomerular Filtration Rate--Reply
JAMA, February 13, 2008; 299(6): 631 - 632.
[Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
M. P. Quinn, A. Rainey, K. J. Cairns, A. H. Marshall, G. Savage, F. Kee, A. Peter Maxwell, E. Reaney, and D. G. Fogarty
The practical implications of using standardized estimation equations in calculating the prevalence of chronic kidney disease
Nephrol. Dial. Transplant., February 1, 2008; 23(2): 542 - 548.
[Abstract] [Full Text] [PDF]


Home page
QJMHome page
P.D. Giles, P.B. Rylance, and D.C. Crothers
New results from the Modification of Diet in Renal Disease study: the importance of clinical outcomes in test strategies for early chronic kidney disease
QJM, February 1, 2008; 101(2): 155 - 158.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
D. M. Parry
Use of Single-Value Protein Compensation of the Jaffe Creatinine Assay Contributes to Clinically Significant Inaccuracy in Results
Clin. Chem., January 1, 2008; 54(1): 215 - 216.
[Full Text] [PDF]


Home page
JAMAHome page
J. Coresh, E. Selvin, L. A. Stevens, J. Manzi, J. W. Kusek, P. Eggers, F. Van Lente, and A. S. Levey
Prevalence of Chronic Kidney Disease in the United States
JAMA, November 7, 2007; 298(17): 2038 - 2047.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
F. Artunc and T. Risler
Serum erythropoietin concentrations and responses to anaemia in patients with or without chronic kidney disease
Nephrol. Dial. Transplant., October 1, 2007; 22(10): 2900 - 2908.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Soc. Nephrol.Home page
L. A. Stevens, J. Coresh, H. I. Feldman, T. Greene, J. P. Lash, R. G. Nelson, M. Rahman, A. E. Deysher, Y. Zhang, C. H. Schmid, et al.
Evaluation of the Modification of Diet in Renal Disease Study Equation in a Large Diverse Population
J. Am. Soc. Nephrol., October 1, 2007; 18(10): 2749 - 2757.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow All Versions of this Article:
clinchem.2006.077180v1
53/4/766    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (92)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Levey, A. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Levey, A. S.
Related Collections
Right arrow Laboratory Management
Right arrow General Clinical Chemistry
Right arrow Other Areas of Clinical Chemistry


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS