Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 53: 1401-1407, 2007. First published June 22, 2007; 10.1373/clinchem.2007.087510
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2007.087510v1
53/8/1401    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sjöholm, M. I. L.
Right arrow Articles by Carlson, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sjöholm, M. I. L.
Right arrow Articles by Carlson, J.
Related Collections
Right arrow Molecular Diagnostics and Genetics
(Clinical Chemistry. 2007;53:1401-1407.)
© 2007 American Association for Clinical Chemistry, Inc.


Molecular Diagnostics and Genetics

Assessing Quality and Functionality of DNA from Fresh and Archival Dried Blood Spots and Recommendations for Quality Control Guidelines

Malin Ida Linnea Sjöholm1,2,3, Joakim Dillner1,3 and Joyce Carlson1,2,a

1 The Swedish National Biobanking Program, Lund University, Malmö University Hospital, Malmö, Sweden.
Departments of2 Clinical Chemistry and 3 Medical Microbiology, Lund University, Malmö University Hospital, Malmö, Sweden.

aAddress correspondence to this author at: Department of Clinical Chemistry, University Hospital MAS, Entrance 71, 20502 Malmö, Sweden. Fax 46-40-33; e-mail Joyce.Carlson{at}med.lu.se.


   Abstract
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 
Background: Dried blood spots (DBS) are a convenient and inexpensive method for biobanking. Although many countries have established population-based DBS biobanks from neonatal screening programs, the quality and usefulness of DNA from DBS have not been extensively assessed.

Methods: We compared 4 common DNA extraction methods (Qiagen, EZNA, Chelex 100, and alkaline lysis) in a pilot study using fresh DBS with known lymphocyte count. We assessed suitability for multiple displacement amplification (MDA) and subsequent single-nucleotide polymorphism (SNP) analyses. We selected the EZNA method for DNA extraction from archival samples up to 27 years old, stored at room temperature or –20 °C, and SNP analyses were performed after MDA.

Results: Extraction using alkaline lysis failed in most tests, and Chelex 100 was unsuccessful in real-time PCR, whereas the EZNA and Qiagen methods were successful by all evaluated quality indices. DNA extraction by EZNA, MDA, and SNP analyses were successful for the archival samples stored at –20 °C.

Conclusion: Routine protocols for evaluation of the quality and functional integrity of DNA based on DNA yield, DNA size, and quantification of amplifiable DNA allow use of sufficient template for MDA and successful SNP analyses from both primary DBS extract and MDA product. A single 3-mm disc can yield sufficient DNA for several thousand SNP analyses. DNA from DBS is thus suitable for genetic epidemiology studies.


   Introduction
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 
Current efforts in molecular oncology and genetic epidemiology increasingly rely on cohorts with available biobanks of DNA-containing samples as the study base. Use of dried blood spots (DBS)1 is a convenient and inexpensive method for biobanking commonly used in low-resource settings as well as a backup strategy for conventional biobanks. DBS sampling has been in routine use for many decades, resulting in many large existing DBS biobanks with long follow-up, corresponding to large numbers of prospectively occurring disease endpoints. The largest DBS-based biobanks have been established for population-based neonatal screening programs for inborn errors of metabolism, notably phenylketonuria (PKU) screening first described by Guthrie and Susi (1) in 1963. Sweden has a national PKU registry in which DBS samples from all newborn infants in Sweden have been stored since 1975. The Swedish PKU registry now contains DBS samples from 3 million individuals, virtually the entire population of Sweden <30 years of age (2). An enormous opportunity for genetic epidemiology has been opened in Sweden by the routine documentation of broad informed consent (3) for medical research on samples collected in routine healthcare (4). A similar possibility has been opened in Denmark by legislation that allows biobank-based medical research unless donors have objected in a nationwide informed dissent registry (5).

The use of DBS extracts for both population genetic (2)(6)(7)(8)(9)(10) and protein (11)(12) studies is not new, but quality standards for optimizing DNA extraction, whole genome amplification, and single-nucleotide polymorphism (SNP) analyses from these precious samples are lacking. The use of whole genome amplification dramatically enhances the possibilities for large-scale studies on limited amounts of sample. Whereas older PCR-based whole genome amplification methods (13)(14) have had limited success, isothermal multiple displacement amplification (MDA) reagent sets using the Phi 29 DNA polymerase (15)(16) are now commercially available and routinely used by biobanks and geneticists.

Here, we evaluated the effect of storage time and temperature on the quality of DNA in DBS and the minimum template amount necessary to ensure biallelic representation after MDA. We describe a protocol that can optimize DNA extraction, MDA, and subsequent SNP analyses and should allow several thousand successful SNP analyses from small DBS punches stored for >20 years; we also describe quality control guidelines.


   Materials and Methods
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 
pilot study
DNA extraction.
We used the QIAamp DNA MiniKit (Qiagen) blood and body fluid spin protocol on 4 anonymized fresh EDTA whole blood samples with known lymphocyte cell counts to serve as a reference for subsequent SNP analyses. Samples were obtained from the Clinical Chemistry Laboratory, University Hospital, Malmö, Sweden. We applied 100-µL aliquots of the blood samples to marked circles, 14 mm in diameter, on filter paper (Schleicher & Schüll 2992) and punched 6-mm diameter discs from each dried filter, with careful cleaning of the punch between samples to prevent contamination. One disc from each sample was then subjected to each of the following DNA extraction methods.

DNA size and concentration.
We measured the concentration of double-strand DNA in primary DBS extract and whole blood by use of the PicoGreen dsDNA Quantification Kit (Molecular Probes) on a FLUOstar Optima plate reader (BMG LABTECH GmbH). We measured total DNA concentration using the OliGreen ssDNA Quantification Kit (Molecular Probes). Yield is expressed as percentage of theoretical DNA content calculated as 7 pg DNA per cell.

The size of extracted DNA fragments was visualized after electrophoresis in a 8 g/L agarose gel (SeaKem, Cambrex BioScience) in TBE buffer (0.09 mol/L Tris, 0.09 mol/L boric acid, 1 mmol/L EDTA) stained with 0.4 g/L ethidium bromide (Applichem GmbH) and compared to the size of a mixture of 2 markers (#SM0191 and GeneRuler 50 bp DNA Ladder, MBI Fermentas).

We analyzed a dilution series from 10 µL to 1 x 10–4 µL primary DBS extract in a 20-µL real-time PCR assay followed by end-point allelic discrimination using reagents designed for a robust F22 [coagulation factor II (thrombin)] g.20210G>A (dbSNP (19) rs1799963) TaqMan MGB assay on a 7900 HT Sequence Detection System (instrument and all TaqMan SNP genotyping assay reagents from Applied Biosystems).

MDA.
We subjected serial dilutions containing from 5 to 0.05 ng (based on PicoGreen quantification) primary DBS extract to MDA using the GenomiPhi Kit. Each aliquot was evaporated to dryness at 37 °C in a 96-well plate before addition of GenomiPhi reagents. After enzyme inactivation, the MDA products were diluted 10-fold with TE buffer (1 mmol/L EDTA, 10 mmol/L Tris-HCl, pH 8.0) and solubilized at 4 °C for at least 6 h. The quantity, by real-time PCR, and size of the MDA product were evaluated as above.

TaqMan MGB SNP analyses.
We performed analyses of the high frequency SNPs MTHFR [5,10-methylenetetrahydrofolate reductase (NADPH)] c.677C>T (rs1801133), MTHFR c.1298A>C (rs1801131), and APOE (apolipoprotein E) c.334T>C (rs429358) on the 7900 HT using 2-µL undiluted extracts from whole blood, DBS, or a 100-fold dilution of MDA product in 6-µL reactions. All assays are accredited by SWEDAC for routine diagnostic testing and were performed with internal controls having wild-type/wild-type, wild-type/mutant, and mutant/mutant genotypes in each assay batch.

We used the VIC:6-carboxyfluorescein (FAM) ratio of fluorescence from ~2200 samples previously analyzed with the same assays for the MTHFR SNPs in our laboratory as criteria for genotype determination. MDA samples were accepted as homozygotes if the FAM:VIC ratio was within 3 SD of the reference homozygous mean ratio and as heterozygotes if the ratio was outside 4 SD of the reference homozygous mean ratio.

Because no such reference data using the same APOE reagents and protocol were available, we confirmed APOE genotypes of samples that were not automatically determined by the 7900 HT software with restriction fragment length polymorphism as described by Hixson and Vernier (20).

Mass spectrometry SNP analyses.
We analyzed a panel of 254 SNP assays on a MALDI-TOF mass spectrometer (SEQUENOM MassArray) using iPLEX reagents and protocol (SEQUENOM) and primer sets (Metabion) previously validated on in-house samples and 10 ng whole blood DNA or MDA product of DBS as PCR template if available.

archival dbs
We obtained anonymous punched discs, 3 mm in diameter, from 10 samples stored for 3 months at –20 °C (Schleicher & Schüll 903), 10 samples stored for ~22 years (obtained 1980–1989) at –20 °C, and 10 samples stored for ~26 years (obtained 1979–1981) at room temperature (both Schleicher & Schüll 2992) from the Danish National PKU Biobank (State Serum Institute). DNA was extracted from a single disc of each sample with the EZNA method and eluted in 50 µL buffer. The 22-year-old samples were extracted in duplicate, 1 disc according to the protocol and a 2nd disc with the proteolysis time increased to 24 h. Five of the 26-year-old samples were extracted in duplicate with increased proteolysis time, and 5 samples had 1 disc extracted according to the protocol and a 2nd disc extracted with the increased proteolysis time.

We measured the DNA concentration by use of real-time PCR and visualized the size of DNA fragments as described above.

Ten microliters of the primary DBS extract from the 3-month-old samples and 5 ng or 20 µL of the primary DBS extract from both duplicates of the 22- and 26-year-old samples were evaporated to dryness at 37 °C. We subjected the pellet to MDA followed by measurement of the DNA concentration by real-time PCR using 2 µL 100-fold diluted MDA product in a 6-µL reaction and the 3 TaqMan SNPs as described above, using primary DBS extract and 100-fold diluted MDA product. All samples were analyzed on a panel of 101 mass spectrometry (MS) SNP assays using 10 ng MDA product as template if available.


   Results
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 
pilot study
Size and concentration of DNA.
Standard DNA minipreps from 200 µL of 4 fresh EDTA-whole blood samples (4.6 to 21.8 x 109 lymphocytes/L) yielded 4 to 20 µg double-stranded DNA (dsDNA) [mean (SD) 58% (4.7%) of theoretical yield]. The apparent size of eluted DNA was 21 kb (Fig. 1 , lane 1).


Figure 1
View larger version (86K):
[in this window]
[in a new window]

 
Figure 1. Pilot study: fragment size of DNA from whole blood, DBS, and MDA products of DBS.

Lane M: high molecular marker; lane 1: 2 µL DNA extracted from whole blood (262 ng); one-third of DNA from the DBS extracted by lane 2: Qiagen (220 ng); lane 3: EZNA (135 ng); lane 4: Chelex 100 (225 ng); and lane 5: alkaline lysis (9.4 ng) methods; 10 µL of MDA products of DNA from DBS extracted by lane 6: Qiagen (114 ng); lane 7: EZNA (114 ng); lane 8: Chelex 100 (138 ng); and lane 9: alkaline lysis (0 ng) methods.

The mean DNA yields from 6-mm DBS discs as measured by PicoGreen fluorescence were 14% (67–306 ng), 12% (62–178 ng), 8% (31–134 ng), and 1% (4–8 ng) using the Qiagen, EZNA, Chelex 100, and alkaline lysis methods, respectively. Quantification by real-time PCR gave similar results for samples isolated with the EZNA and Qiagen methods (Fig. 2 ). Extraction with Chelex 100 resulted in small amounts of functional, real-time PCR amplifiable DNA (Fig. 2 ), and a 20% Chelex 100 concentration did not improve the yield of functional DNA (not shown). DNA extracted by alkaline lysis failed consistently in real-time PCR assays. Optimal template dilution of primary DBS extracts from the EZNA and Qiagen methods was typically 20- to 2000-fold in real-time PCR assays. Only data within the linear range were used to calculate DNA concentrations (Fig. 3 ). OliGreen fluorescence data agreed poorly with the PicoGreen and real-time PCR data regardless of extraction method (Fig. 2 ).


Figure 2
View larger version (15K):
[in this window]
[in a new window]

 
Figure 2. Pilot study: yield of DNA from a 6-mm DBS disc.

Mean percentage of theoretical DNA content of 4 samples, analyzed in duplicate by PicoGreen and OliGreen fluorescence or by real-time PCR in a dilution series.


Figure 3
View larger version (14K):
[in this window]
[in a new window]

 
Figure 3. Pilot study: DNA quantification by real-time PCR of a typical DBS sample extracted by Qiagen, EZNA, and Chelex 100 methods.

The apparent size of DBS DNA extracted with the Qiagen and EZNA methods was 21 kb, and >21 kb with the Chelex 100 method. The alkaline lysis method produced insufficient DNA to be visible on gel electrophoresis (Fig. 1Up , lanes 2–5).

MDA.
We used dilution series of DNA (5 to 0.05 ng) from 3 DBS samples as templates for MDA and measured the DNA concentration of the MDA product by use of real-time PCR. Results are presented in Table 1 . The majority of DNA fragments after MDA, using 5 ng template DNA, appeared to be 21 to 3.5 kb in length (Fig. 1Up , lanes 6–8). Repeated attempts with MDA of alkaline lysis-extracted samples consistently failed to produce any measurable amount of functional DNA (Fig. 1Up , lane 9).


View this table:
[in this window]
[in a new window]

 
Table 1. Pilot study: DNA yields and TaqMan SNP results from MDA products of 2 typical DBS samples according to template.

SNP analyses.
To evaluate the minimal amount of template DNA in the MDA reaction necessary to retain biallelic representation, we compared results of the TaqMan analyses (Table 1Up ) and a panel of 254 SNPs analyzed by MS (Table 2 ) on QIAamp MiniKit-preps of 3 whole blood samples to those of MDA products from the dilution series of DBS DNA from the same samples. Identical TaqMan results were obtained if >0.15 ng MDA template had been used, except for 1 sample extracted by the Qiagen method for which allelic dropout was seen when ≤0.5 ng was used. Using <0.15 ng as MDA template resulted in failed amplification or failed or irreproducible SNP analyses in all samples (Table 1Up ).


View this table:
[in this window]
[in a new window]

 
Table 2. MS SNP results of whole blood DNA and MDA products of DBS samples according to template.

The success rate in the MS SNP analyses was 98.0% for DNA from whole blood and 97.9% for MDA product using 5 ng template of DBS DNA extracted with the EZNA method. No allelic dropout was seen in the MDA product from these EZNA-extracted DBS samples. Corresponding rates for MDA products were 97.2% after Qiagen and Chelex 100 extractions. The success rates decreased when lower amounts of template DNA were used in the MDA reaction. Although most genotyping failures were due to missing values, allelic dropout was seen in a small percentage of the samples (Table 2Up ).

archival dbs
Discs of 3 mm diameter were used from all archival DBS. The mean (SD; range) DNA yield from 1 disc was 12.7 (7.1; 5.3–30.4) ng for the 3-month-old samples, 33.8 (9.8; 20.8–48.5) ng for the 22-year-old samples stored at –20 °C, and 24.5 (16.3; 8.0–66.9) ng for the 26-year-old samples stored at room temperature, the latter 2 extracted after proteolysis for 24 h. The mean (SD; range) DNA yield was 17.2 (20.9; 3.0–82.7) ng for the 22- and 26-year-old samples combined, extracted according to the original EZNA protocol, compared with 28.3 (14.6; 8.04–66.9) ng for the 22- and 26-year old samples combined, extracted after proteolysis for 24 h.

The degree of fragmentation of DNA extracted from archival DBS increased with increasing age of the samples (Fig. 4 , lanes 1–3). TaqMan SNP analyses were successful on all archival samples, using primary DBS extract as template.


Figure 4
View larger version (81K):
[in this window]
[in a new window]

 
Figure 4. Fragment size of DNA extracted from archival DBS and MDA products of archival DBS.

Lane M: high molecular marker; lane 1: DNA extracted from 3-month-old DBS (120 ng); lane 2: 22-year-old DBS (127 ng); and lane 3: 26-year-old DBS (112 ng). Lane 4: MDA products of DBS extracted from 3-month-old; lane 5: 22-year-old; and lane 6: 26-year-old samples (all 150 ng).

Although several samples, irrespective of age, produced insufficient DNA for 5 ng to be used as MDA template, the use of duplicates for the 22- and 26-year-old samples provided at least 1 MDA reaction per sample donor with ≥5 ng template DNA. MDA was successful on the 3-month-old samples, with a mean (SD) yield of 11 620 (4624) ng, and the 22-year-old samples, with a mean yield of 6383 (2872) ng. MDA on the 26-year-old samples resulted in a mean yield of 17 (14) ng when measured by real-time PCR. Using PicoGreen for measuring concentration of the 26-year-old samples suggested a mean yield of 5000 (1591) ng. The majority of fragments after MDA appeared to be 21 to 3.5 kb in length regardless of storage length or temperature (Fig. 4Up , lanes 4–6).

In the TaqMan analyses, 3 of the 26-year-old samples showed allelic dropout when comparing the genotypes determined using the MDA products of 5 ng DBS DNA to those determined using the primary DBS extract; the genotypes were identical for all other archival samples.

We analyzed all archival samples for a panel of 101 SNPs by MS. The concordance rate for the 3-month-old samples was 97.5%, between 2 aliquots of the MDA reactions. The success rate was 97.5% for the 22-year-old samples and 84.7% for the 26-year-old samples. Success rates of the 22- and 26-year-old samples were calculated from samples where ≥5 ng template DNA had been used in the MDA reaction. The discrepancy rate was 0.1% between duplicate aliquots of the MDA products for the 3-month-old samples, and 0.1% and 10.3% between MDA products from duplicate extracted discs from the DBS for the 22- and 26-year-old samples, respectively (Table 2Up ). When including genotyping results from the samples with <5 ng MDA template, the discrepancy rates between 2 discs of the DBS were 0.4% and 12.7% for the 22- and 26-year-old samples, respectively.


   Discussion
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 
Archival DBS samples stored at –20 °C performed equally well as freshly prepared DBS samples in the TaqMan analyses. In the MS SNP analyses, the 22-year-old DBS samples performed as well as the 3-month-old DBS samples and nearly as well as freshly prepared DBS samples. Missing values were only slightly more common in the DNA from these archival samples, and we found a small percentage (0.1%) of discrepancies between duplicate aliquots of the MDA products of the 3-month-old and between MDA products from duplicate extracted discs from the DBS of the 22-year-old samples, compared with the fresh samples extracted with the EZNA method. Although DNA yields from the archival DBS, using the original EZNA protocol, appeared similar, fragmentation of the DNA increased and performance in SNP analyses after MDA decreased with increasing storage time and temperature. The 26-year-old samples showed discrepancies between the primary DBS extract and the MDA product of the same DNA in the TaqMan analyses and the highest percentage of missing values and discrepancies between MDA products from duplicate extracted discs from the DBS in the MS SNP analyses. These samples also performed poorly in real-time PCR after MDA, and the amount of MDA product was estimated by PicoGreen fluorescence. This overall poor performance could be due to the low molecular weight of the DNA extracted from these samples, probably caused by degradation of the DNA during room temperature storage as previously suggested (21). A larger amount of template from these samples could be used in MDA reactions to compensate for the degradation. Unfortunately, the small amounts of DNA yielded from the DBS did not allow for enrichment of large fragments or for repeated MDA reactions in our study. The PicoGreen assay is not optimal for MDA products, as even nontemplate controls sometimes produce considerable dsDNA owing to primer-on-primer amplification products. Nonetheless, the apparent success rate in MS SNP analyses of nearly 85% for the 26-year-old samples indicates that considerable amplification must have occurred during the MDA reaction, which was confirmed by gel analysis.

Maintenance of biallelic representation in SNP assays required the use of a minimum of 5 ng DNA as template in the MDA reaction, similar to our findings in a previous study (22). This could be routinely obtained from the archival samples if the duration of the proteolysis step in the EZNA extraction method was increased.

If routine protocols using a minimum of 5 ng intact DNA as MDA template and 2 or 10 ng MDA product in TaqMan or MS SNP analyses, respectively, are followed, a 3-mm archival DBS disc should be sufficient for ~7000 TaqMan SNP analyses or ~39 000 (28 assays/multiplex) or ~56 000 (40 assays/multiplex) MS SNP assays (assuming an ~16 ng DNA yield per 3-mm disc and ~4700 ng yield per MDA reaction). The yield of 1 MDA reaction would also be more than sufficient for most whole-genome scan platforms.

The Qiagen, EZNA, and Chelex 100 methods all generated DNA from DBS of sufficient quality to perform well in SNP analyses after MDA, contrary to reports of previous studies in which DBS DNA were found inappropriate for MDA (21). Although very small amounts of template DNA were greatly amplified by MDA, generating enough DNA for a large number of SNP assays, allelic dropout increased with decreasing amounts of MDA template.

The fact that the Chelex 100-extracted DNA was quantifiable using PicoGreen and was a suitable target for MDA indicates that this method extracted substantial amounts of DNA, but the extracts contained impurities that inhibited real-time PCR. The high molecular weight of the DNA in the Chelex 100 extract could indicate that this method produces more intact DNA than the other methods. An alternative interpretation could be that the sample impurities that were clearly visible in the gel-well might have caused clogging and delayed the DNA in entering the gel.

The agreement of results of PicoGreen fluorescence and real-time PCR quantification indicate the presence of intact DNA with little inhibition in the Qiagen and EZNA primary DBS extracts. OliGreen consistently overestimated the DNA content of extracts and is not recommended. The DNA yields from DBS are altogether too low to allow reliable quantification by ultraviolet Abs 260/280.

When genotyping high-quality DNA, the samples usually separate into neat, tight clusters according to genotype in the 7900 HT scattergram, with little variation in the FAM:VIC fluorescence ratios. Allelic discrimination of MDA products of heterozygous samples was more difficult, with greater variation in fluorescent ratios. The reference material was therefore used as an objective method to confirm the genotype of these samples.

In summary, for optimal DNA analyses from DBS, we recommend storage of DBS at –20 °C to prevent degradation of DNA, prolonged proteolysis steps during DNA extraction for optimal yield, the use of >5 ng intact DNA as MDA template, and solubilization of MDA product by 10-fold dilution with TE buffer for at least 6 h. Our recommendations for quality control guidelines include (a) quality-assured storage and documentation of samples before analysis, (b) tracking of sample identity throughout all processes, and (c) DNA extraction by a validated method. Validation includes (a) evaluation of fragment size on agarose gel electrophoresis, (b) quantification of dsDNA by PicoGreen fluorescence and comparison with real-time PCR in more than 1 dilution to reveal inhibitors and to confirm the presence of intact functional human DNA, and (c) performance of MDA on extracted DNA and evaluation of the product by real-time PCR. Using these guidelines, archival DBS samples can provide sufficient DNA for successful large-scale genetic epidemiological studies.


   Acknowledgments
 
Grant/funding support: This study has been supported by the Swedish National Biobanking Program, financed by the Knut and Alice Wallenberg Foundation and by the EU 6th Framework Grant CCPRB (Cancer Control Using Population-Based Registries and Biobanks), Principal Investigator, Joakim Dillner.

Financial disclosures: None declared.

Acknowledgments: We thank Bent Norgaard-Pedersen at Statens Seruminstitute, Copenhagen, Denmark, for kindly providing the archival DBS samples; Christer Halldén for kindly providing the panel of MS SNP assays; and Maria Sterner and Liselotte Hall for preparing the spectroCHIPs and running the MassArray.


   Footnotes
 
1 Nonstandard abbreviations: DBS, dried blood spots; PKU, phenylketonuria; MDA, multiple displacement amplification; SNP, single-nucleotide polymorphism; FAM, 6-carboxyfluorescein; MS, mass spectrometry; dsDNA, double-stranded DNA.

2 Human genes: F2, coagulation factor II (thrombin); MTHFR, 5,10-methylenetetrahydrofolate reductase (NADPH); APOE, apolipoprotein E.


   References
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
 

  1. Guthrie R, Susi A. A simple phenylalanine method for detecting phenylketonuria in large populations of newborn infants. Pediatrics 1963;32:338-343.[Abstract/Free Full Text]
  2. Hannelius U, Lindgren CM, Melén E, Malmberg A, von Dobeln U, Kere J. Phenylketonuria screening registry as a resource for population genetic studies. J Med Genet 2005;42:e60.[Abstract/Free Full Text]
  3. Hansson MG, Dillner J, Bartram CR, Carlson JA, Helgesson G. Should donors be allowed to give broad consent to future biobank research?. Lancet Oncol 2006;7:266-269.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  4. Dillner J. [The new biobank law accepted: a unique chance of improvement]. Lakartidningen 2002;99:2774-2776.[Medline] [Order article via Infotrieve]
  5. Dillner J. [The survey of Danish biobanks suggests a "drop-out" registry]. Lakartidningen 2002;99:4384-4385.[Medline] [Order article via Infotrieve]
  6. Borras E, Coutelle C, Rosell A, Fernandez-Muixi F, Broch M, Crosas B, et al. Genetic polymorphism of alcohol dehydrogenase in Europeans: the ADH2*2 allele decreases the risk for alcoholism and is associated with ADH3*1. Hepatology 2000;31:984-989.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  7. Fitness J, Dixit N, Webster D, Torresani T, Pergolizzi R, Speiser PW, Day DJ. Genotyping of CYP21, linked chromosome 6p markers, and a sex-specific gene in neonatal screening for congenital adrenal hyperplasia. J Clin Endocrinol Metab 1999;84:960-966.[Abstract/Free Full Text]
  8. Lin Z, Suzow JG, Fontaine JM, Naylor EW. A high throughput beta-globin genotyping method by multiplexed melting temperature analysis. Mol Genet Metab 2004;81:237-243.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  9. Mitterer G, Bodamer O, Harwanegg C, Maurer W, Mueller MW, Schmidt WM. Microarray-based detection of mannose-binding lectin 2 (MBL2) polymorphisms in a routine clinical setting. Genet Test 2005;9:6-13.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  10. Zhong XB, Leng L, Beitin A, Chen R, McDonald C, Hsiao B, et al. Simultaneous detection of microsatellite repeats and SNPs in the macrophage migration inhibitory factor (MIF) gene by thin-film biosensor chips and application to rural field studies. Nucleic Acids Res 2005;33:e121.[Abstract/Free Full Text]
  11. Lorey F, Cunningham G, Vichinsky EP, Lubin BH, Witkowska HE, Matsunaga A, et al. Universal newborn screening for Hb H disease in California. Genet Test 2001;5:93-100.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  12. Hoffman BR, Yu H, Diamandis EP. Assay of prostate-specific antigen from whole blood spotted on filter paper and application to prostate cancer screening. Clin Chem 1996;42:536-544.[Abstract/Free Full Text]
  13. Cheung VG, Nelson SF. Whole genome amplification using a degenerate oligonucleotide primer allows hundreds of genotypes to be performed on less than one nanogram of genomic DNA. Proc Natl Acad Sci U S A 1996;93:14676-14679.[Abstract/Free Full Text]
  14. Kittler R, Stoneking M, Kayser M. A whole genome amplification method to generate long fragments from low quantities of genomic DNA. Anal Biochem 2002;300:237-244.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  15. Dean FB, Hosono S, Fang L, Wu X, Faruqi AF, Bray-Ward P, et al. Comprehensive human genome amplification using multiple displacement amplification. Proc Natl Acad Sci U S A 2002;99:5261-5266.[Abstract/Free Full Text]
  16. Lage JM, Leamon JH, Pejovic T, Hamann S, Lacey M, Dillon D, et al. Whole genome analysis of genetic alterations in small DNA samples using hyperbranched strand displacement amplification and array-CGH. Genome Res 2003;13:294-307.[Abstract/Free Full Text]
  17. AmershamBiosciences. GenomiPhi DNA Amplification Kit, Instructions. http://www.amershambiosciences.com (accessed October 2005)..
  18. AmershamBiosciences. Whole genome amplification from blood cards. http://www.amershambiosciences.com (accessed October 2005)..
  19. NCBI. Entrez SNP Single Nucleotide Polymorphism. http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=snp (accessed February 2007)..
  20. Hixson JE, Vernier DT. Restriction isotyping of human apolipoprotein E by gene amplification and cleavage with HhaI. J Lipid Res 1990;31:545-548.[Abstract]
  21. Park JW, Beaty TH, Boyce P, Scott AF, McIntosh I. Comparing whole-genome amplification methods and sources of biological samples for single-nucleotide polymorphism genotyping. Clin Chem 2005;51:1520-1523.[Free Full Text]
  22. Sjoholm MI, Hoffmann G, Lindgren S, Dillner J, Carlson J. Comparison of archival plasma and formalin-fixed paraffin-embedded tissue for genotyping in hepatocellular carcinoma. Cancer Epidemiol Biomarkers Prev 2005;14:251-255.[Abstract/Free Full Text]



The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
S. A. Bustin, V. Benes, J. A. Garson, J. Hellemans, J. Huggett, M. Kubista, R. Mueller, T. Nolan, M. W. Pfaffl, G. L. Shipley, et al.
The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments
Clin. Chem., April 1, 2009; 55(4): 611 - 622.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Microbiol.Home page
M. I. L. Sjoholm, J. Dillner, and J. Carlson
Multiplex Detection of Human Herpesviruses from Archival Specimens by Using Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry
J. Clin. Microbiol., February 1, 2008; 46(2): 540 - 545.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2007.087510v1
53/8/1401    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sjöholm, M. I. L.
Right arrow Articles by Carlson, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sjöholm, M. I. L.
Right arrow Articles by Carlson, J.
Related Collections
Right arrow Molecular Diagnostics and Genetics


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS