| Abstract |
|---|
|
|
|---|
Methods: We measured cardiac troponin I (cTnI) on admission and 6–24 h after admission (follow-up) in plasma specimens from 371 consecutive patients. The end point was the first of cardiac event or death within 60 days. We estimated survival curves using the Kaplan-Meier method and compared groups with the log rank statistic.
Results: MI was established in 49 patients (13%). Clinical sensitivities and specificities for MI based on the 99th percentile (0.04 µg/L) were 74% and 84%, respectively, on admission and 94% and 81% at follow-up. ROC curves showed significantly higher accuracy for MI in the follow-up specimen compared with admission (P = 0.001). Overall there were 2 cardiac deaths, 1 noncardiac death, 49 MIs, 7 coronary artery bypass grafts, and 36 percutaneous coronary interventions in 59 patients during follow-up. The event rate in those with cTnI <0.006 µg/L was significantly lower than in groups with cTnI 0.006–0.04 µg/L, >0.04–0.10 µg/L, or >0.10 µg/L (2.8% vs 11.1%, 24.1%, 55.1%, respectively; P <0.0001). Relative risks for the increasing cTnI cutoff groups were 3.9 (95% CI 1.2–13), 8.9 (2.4–34), and 25 (7.3–82) after adjustment for age, diabetes, history of hypertension, previous MI, and estimated glomerular filtration rate.
Conclusions: The TnI-Ultra assay is a sensitive, early diagnostic biomarker for MI and an independent predictor of adverse events at any measurable cTnI in patients with symptoms of acute coronary syndrome.
| Introduction |
|---|
|
|
|---|
| Materials and Methods |
|---|
|
|
|---|
Plasma was initially stored refrigerated at –4 °C, and then frozen at –80 °C within 48–72 h. We measured cTnI by use of the second-generation Bayer (now Siemens) Advia Centaur TnI-Ultra assay following manufacturers guidelines. cTnI values used for diagnostic and risk assessment calculations were those designated by the manufacturers claims in their FDA-cleared package insert as the LoD of 0.006 µg/L and the 99th percentile reference value of 0.040 µg/L. Assay total imprecision was reported by Siemens to be 10% at 0.03 µg/L. Total imprecision in the study laboratory was 3.5% for our lowest quality control material, mean 0.26 µg/L over 19 days.
We obtained patient demographics and determination of clinical diagnoses from chart review after patient enrollment into the study. Record review included up-to-date medical history of previous medical conditions and was carried out blinded to biomarker results. Criteria for acute MI were defined along the European Society of Cardiology/American College of Cardiology redefinition of myocardial infarction guidelines(1). This was based on evidence of myocardial necrosis in a clinical setting consistent with myocardial ischemia at presentation. A diagnosis of MI was made based on detection of an increase of cTnI (Dade Behring Dimension or Stratus CS as used by Hennepin in their laboratories) above the 99th percentile reference value (<0.1 µg/L; total imprecision 12% at 0.2 µg/L) with at least one of the following: symptoms of ischemia, new ST-T changes on ECG, development of Q waves on ECG, or imaging evidence of new loss of viable myocardium.
We performed chart reviews or telephone follow-up interviews to determine clinical outcomes over 60 days (without knowledge of the cTnI finding). Follow-up information was not available for 10 patients, who are excluded from further analysis. The primary end point for this study was a combined end point: first cardiac event (MI, percutaneous coronary intervention [PCI], coronary artery bypass graft [CABG]) or death within 60 days. Exposure was computed from date of blood draw until date of first event, with censoring at time of last contact if <60 days. Cumulative event rates were estimated using the Kaplan-Meier method and compared using the log rank statistic. We estimated relative risks (RRs) and 95% CIs using Cox proportional hazards models. Statistical significance was accepted at the 0.05 level, and all statistical tests were 2 sided. Statistical analyses were performed with MedCalc 9.3.0.0 (www.medcalc.be) and SPSS for Windows version 11.5 (SPSS).
| Results |
|---|
|
|
|---|
|
MI was established in 49 patients (13.2%) during initial hospitalization. Clinical sensitivities and specificities based on the 99th percentile (0.04 µg /L) were 74% and 84%, respectively, at baseline and 94% and 81% at follow-up (10 h median time to follow-up sample; Table 2
). A higher diagnostic accuracy for MI was observed with the follow-up specimen vs the baseline sample as evidenced by a higher area under the ROC (area under curve [AUC] 0.957 vs 0.860, P = 0.001; Fig. 1
). Using the LoD concentration cutoff (
0.006 µg/L) as the diagnostic threshold increased sensitivity for both baseline and follow-up samples to >95% but reduced specificity to <35%. For comparison, at the 99th percentile–derived cutoff of 0.1 µg/L as determined for the first-generation Bayer Centaur assay, sensitivities were lower at both baseline (55%) and follow-up (86%) sampling compared with the 99th percentile cutoff, whereas specificities were >90%. Based on the Dade cTnI <0.1 µg/L 99th percentile value used at the hospital lab, the clinical sensitivity was 58% (CI 43% to 72%) and specificity was 89% (CI 85% to 92%) for the baseline sample (n = 359). For the follow-up specimen (n = 346), the sensitivity was 96% (CI 85% to 99%) and specificity was 87% (CI 83% to 91%). The area under the ROC was significantly higher at baseline for Siemens cTnI vs Dade cTnI (0.86 vs 0.77, P = 0.01; n = 359) but not at follow-up (0.97 vs 0.96, P = 0.58; n = 346). Further examination of cTnI sensitivities and specificities broken down for samplings in the 6- to 12-h range (n = 249) and 12- to 18-h range (n = 106) demonstrated the following sensitivities and specificities: 6- to 12-h sensitivity, Siemens 90%, Dade 86%; 6- to 12-h specificity, Siemens 83%, Dade 92%; 12- to 18-h sensitivity, Siemens 100%, Dade 100%; 12- to 18-h specificity, Siemens 79%, Dade 87%. As there were only 12 draws in the 18+ h group, no data are provided.
|
|
Increasing 60-day event rates (cardiac event and death) were observed with increasing cTnI concentrations (Table 3
, Fig. 2
). The 60-day event rate was significantly lower in the <LoD group (2.8%) than in either the intermediate group (11.1%) (P = 0.01) or the increased cTnI (>99th percentile) group (42%) (P <0.0001). In the 89 patients with cTnI concentration above the 99th percentile cutoff (0.04 µg/L), patients with a concentration up to 0.1 µg/L (n = 38) had a 60-day event rate of 24% vs 55% for patients (n = 51) with a concentration >0.10 µg/L (P = 0.004). Compared with the <LoD cTnI group, the relative risk of an event was 3.9 (CI 1.2–13) in the intermediate group and 8.9 (2.4–34) in the >99th percentile group and 24.5 (7.3–82) in the >0.10 µg/L group after adjustment for age, eGFR, diabetes, history of hypertension, and previous MI. Table 3
also demonstrates the 60-day event rate for MI and cardiac death alone. Similar significant RRs are shown at all cutoff concentrations examined, and ranged from 3.3 at <0.006 µg/L to 34.9 at >0.10 µg/L (P <0.001). No MIs were related to PCI or CABG procedures for outcomes assessment.
|
|
Of the 3 deaths that occurred, none were in patients with a cTnI below the LoD. One death occurred in a patient with a concentration below the 99th percentile cutoff, and the other 2 above 0.010 µg/L.
| Discussion |
|---|
|
|
|---|
0.04 µg/L. This is a substantial improvement compared to first-generation cTnI and cTnT assays, including Bayers initial first-generation cTnI assay, which demonstrated clinical sensitivities of 3% to 33% that were not different from sensitivities for creatine kinase MB assays(9)(10)(11). Further, our findings demonstrated a 94% sensitivity in the 6- to 24-h follow-up sample, again a substantial improvement compared with first-generation cTn assays, which showed substantially lower sensitivities of 50% to 92% in specimens collected 6–24 h after baseline(9)(10)(11). Surprisingly few published studies have clearly demonstrated this improvement in diagnosing MI using second-generation cTnI assays. Our data add to the evidence-based literature supporting reliable triage capabilities based on the use of the second-generation Siemens assay. The improved sensitivity that coincides with lowering the diagnostic cutoff to the 99th percentile value comes with a specificity trade-off, however. Because first-generation cTn assays were not as robust analytically, cutoff concentrations based on higher WHO (ROC-derived cutoff optimized for clinical sensitivity and specificity) biomarker criteria demonstrated clinical specificities >90%(12). The clinical specificity of 84% in the present study at baseline using the analytically sensitive second-generation Siemens assay demonstrates that other pathology mechanisms besides ischemic MI were responsible for myocardial injury. It is now well described that increases in cardiac troponin occur in the absence of overt ischemic heart disease(1)(12). Although 6 of 10 patients who had increased cTnI in the current study did not have an MI, prognostic value is still added with this biomarker information; the clinician must frame the results accordingly with the patients clinical presentation. These non-MI cTnI increases, therefore, do not represent false-positive findings, although these do occur rarely(13). To aid the clinician in determining the etiology of an increased cTnI in a questionable MI clinical presentation, a temporal, rising pattern of cTnI also assists in the diagnosis of MI(1)(2). Increased cTnI concentrations that do not change over time are very unlikely due to an MI(3)(12)(14). These observations are consistent with recent guidelines on the use of cardiac troponin in the initial evaluation of ACS(1)(2). Our observations also demonstrate that the Siemens cTnI assay showed a significantly greater ROC AUC (0.86) compared with the Dade cTnI at baseline (0.77), but not after 6 h in follow-up specimens. We note, as a potential limitation, the modest number of patients studied.
Our findings using the second-generation Siemens Ultra assay complement a recent risk stratification study from Sweden, which demonstrated using the second-generation Beckman cTnI assay that any detectable cTnI was a predictor of coronary artery disease and mortality in 70-year-old men with and without known cardiovascular disease(15). Their findings demonstrated greater risk of adverse events in the group of patients with measurable but normal values compared with the cTnI values less then the LoD, comparable to our findings with the Siemens Ultra assay. Whereas similar findings have been described in patients with high-risk unstable angina and non-ST elevation myocardial infarction(9)(15), our findings are the first to describe risk stratification to rule out MI using this second-generation assay in a heterogeneous nonselected patient group presenting with symptoms suggestive of acute coronary syndrome. We have based our outcomes analysis on the initial plasma sampling, before clinical diagnosis. Thus, including the initial diagnosis for the 49 MI patients in our risk stratification may be considered a study limitation.
Previous risk stratification data were published for the first-generation Bayer assay(16)(17). But the reader must understand that absolute concentrations between the first- and second-generation Bayer/Siemens assays cannot be compared, as different antibodies and calibrators were used in the 2 assays. The first-generation cTnI assay that used the Bayer ACS:180 analyzer had both poor low-end concentration analytical sensitivity and poor low-end precision. Outcomes were initially stratified based on a cTnI concentration of 0.1 µg/L, which was the respective 99th percentile value for this first-generation Bayer assay, a value 2.5-fold higher than the second-generation Siemens Ultra assay 99th percentile (0.04 µg/L) used in the current study. The LoD of this first-generation assay was 0.03 µg/L, 5-fold higher than the Ultra assay LoD (0.006 µg/L) of the present study. Risk stratification using the first-generation assay was demonstrated in the TACTICS TIMI-18 (Treat Angina with Aggrastat and Determine Cost of Therapy with an Invasive or Conservative Strategy—Thrombolysis in Myocardial Infarction) trial, with cTnI increases >0.1 µg/L identifying high-risk patients who derived clinical benefit from early invasive strategy(6). We speculate that, given the increased incidence of 60-day events in patients with detectable TnI levels by the second-generation Ultra assay, the number of patients in TACTICS TIMI-18 who would have been identified as benefiting from invasive therapy might have been greater with use of the second-generation assay.
In conclusion, we demonstrate acceptable clinical sensitivity for detection of MI using the 99th percentile reference value, with increasing sensitivity over time after presentation. Further, our data add to the growing evidence that with improved, analytically robust cTn assays with low LoDs, any measurable cTnI implies a higher risk than cTnI concentrations below an assays LoD. We believe that this biomarker will assist in early and improved patient triage, management, and outcomes.
| Acknowledgments |
|---|
Financial Disclosures: F.S.A. has received grant funding from Abbott Laboratories, Siemens (Bayer, Dade-Behring, DPC), Mitsubishi Kagaku Iatron, Ortho-Clinical Diagnostics, bioMerieux, Response Biomedical, Roche Laboratories, Radiometer Medical, BioRad, Biosite, and Wyeth Pharmaceuticals; has consulted for Abbott Laboratories, Ortho-Clinical Diagnostics, Sensera, and InterMune; and has served on the following scientific and medical advisory boards: Abbott Laboratories, Biosite, Beckman Coulter, and Sensera.
| Footnotes |
|---|
| References |
|---|
|
|
|---|
The following articles in journals at HighWire Press have cited this article:
![]() |
F. S. Apple A New Season for Cardiac Troponin Assays: It's Time to Keep a Scorecard Clin. Chem., July 1, 2009; 55(7): 1303 - 1306. [Full Text] [PDF] |
||||
![]() |
T. Reichlin, W. Hochholzer, C. Stelzig, K. Laule, H. Freidank, N. G. Morgenthaler, A. Bergmann, M. Potocki, M. Noveanu, T. Breidthardt, et al. Incremental value of copeptin for rapid rule out of acute myocardial infarction. J. Am. Coll. Cardiol., June 30, 2009; 54(1): 60 - 68. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. S. Apple, L. A. Pearce, S. W. Smith, J. M. Kaczmarek, and M. M. Murakami Role of Monitoring Changes in Sensitive Cardiac Troponin I Assay Results for Early Diagnosis of Myocardial Infarction and Prediction of Risk of Adverse Events Clin. Chem., May 1, 2009; 55(5): 930 - 937. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. S. Jaffe and F. S. Apple Refining Our Criteria: A Critical Challenge Am J Clin Pathol, January 1, 2009; 131(1): 11 - 13. [Full Text] [PDF] |
||||
![]() |
K. M. Eggers, A. S. Jaffe, L. Lind, P. Venge, and B. Lindahl Value of Cardiac Troponin I Cutoff Concentrations below the 99th Percentile for Clinical Decision-Making Clin. Chem., January 1, 2009; 55(1): 85 - 92. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. S. Apple, S. W. Smith, L. A. Pearce, and M. M. Murakami Assessment of the Multiple-Biomarker Approach for Diagnosis of Myocardial Infarction in Patients Presenting with Symptoms Suggestive of Acute Coronary Syndrome Clin. Chem., January 1, 2009; 55(1): 93 - 100. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Venge, S. James, L. Jansson, and B. Lindahl Clinical Performance of Two Highly Sensitive Cardiac Troponin I Assays Clin. Chem., January 1, 2009; 55(1): 109 - 116. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. A. Dawson, G. P. Whyte, M. A. Black, H. Jones, N. Hopkins, D. Oxborough, D. Gaze, R. E. Shave, M. Wilson, K. P. George, et al. Changes in vascular and cardiac function after prolonged strenuous exercise in humans J Appl Physiol, November 1, 2008; 105(5): 1562 - 1568. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |