Clinical Chemistry 55: 578-580, 2009; 10.1373/clinchem.2008.112946
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Simons, S. A.
Right arrow Articles by Hoofnagle, A. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Simons, S. A.
Right arrow Articles by Hoofnagle, A. N.
(Clinical Chemistry. 2009;55:578-580.)
© 2009 American Association for Clinical Chemistry, Inc.


Clinical Case Study

Two Cases with Unusual Vancomycin Measurements

Stacey A. Simons, Alejandro R. Molinelli, Kimia Sobhani, Petrie M. Rainey and Andrew N. Hoofnaglea

1 Department of Laboratory Medicine, University of Washington Medical Center, Seattle, WA

aAddress correspondence to this author at: University of Washington Medical Center Department of Laboratory Medicine, 1959 NE Pacific Street, Box 357110, Seattle, WA 98195. Fax (206)598-6189; e-mail ahoof{at}u.washington.edu.


CASE

Patient A was a 68-year-old woman with a history of lymphoplasmacytic lymphoma who presented after several weeks of mucosal bleeding. On admission, her cancer involved 95% of bone marrow cells. She was pancytopenic and febrile (38.3 °C). Leukocyte count was 0.39 x 103/µL (neutrophils, 0.03 x 103/µL), hematocrit 25%, platelet count 21 x 103/µL, relative serum viscosity 2.3 (reference interval, 1.4–1.8), blood urea nitrogen 6.4 mmol/L (18 mg/dL), creatinine 62 µmol/L (0.7 mg/dL), and estimated glomerular filtration rate >60 mL/min/1.73 m2. She had an IgM{kappa} monoclonal component of 42.8 g/L. This patient was started on vancomycin 1 g intravenously (IV) every 12 h, ceftazidime 2 g IV every 8 h, and a course of chemotherapy. On day 3 after the beginning of antibiotic treatment, a trough specimen was collected for measurement of vancomycin. The concentration, measured with a Beckman Coulter Synchron competitive turbidimetric immunoassay, was <0.1 mg/L. The result, which was incompatible with ongoing vancomycin therapy, signaled a problem to the technologist. No analytical issues were evident upon review of calibration, controls, and results for other chemistry tests performed on the same specimen. In an attempt to resolve an apparent falsely low result, a 1:1 mix of the specimen was made with the Beckman liquid comprehensive control serum (level 3, 30.4 mg/L) and demonstrated near complete recovery (result of mix after adjusting for dilution, 28.6 mg/L). However, a 1:1 mix with pooled patient serum containing vancomycin (11 mg/L) led to only 15% recovery (result of mix after adjustment for dilution, 1.7 mg/L). The specimen was subsequently sent to another laboratory, where a vancomycin concentration of 9.8 mg/L was measured by use of a competitive enzyme-linked immunoassay (Emit, Olympus).

Patient B was a 64 year-old woman with a history of non-Hodgkin lymphoma admitted for stem cell transplantation. Her hospital course included acute renal failure, mental status changes, and disseminated intravascular coagulation. Leukocyte count was 2.18 x 103/µL (neutrophils 1.79 x 103/µL), hematocrit 28%, platelet count 7 x 103/µL, blood urea nitrogen 23 mmol/L (64 mg/dL), creatinine 160 mmol/L (1.8 mg/dL), and estimated glomerular filtration rate of 22 mL/min/1.73 m2. She had an IgM{lambda} monoclonal component of 10.0 g/L, with decreased normal gammaglobulins. This patient was started on vancomycin 750 mg IV every 24 h and imipenim-cilastatin 250 mg IV every 8 h for fever of unknown origin (38.2 °C). On day 2, a vancomycin trough specimen was collected just before administration of the second dose. The result was suppressed by the analyzer, which reported "reaction rate high," i.e., faster than would be seen even in the absence of vancomycin. Calibration, controls, and the day’s vancomycin test results were reviewed and showed no problems. The inappropriate reaction rate repeated with dilution, and also occurred with analysis of 2 other specimens from patient B. The specimen was subsequently sent to another laboratory, where a vancomycin concentration of 6.9 mg/L was measured with a competitive enzyme-linked immunoassay (Emit, Ortho-Clinical).


DISCUSSION

what might have caused the problems in measuring vancomycin observed in these two patients?
Vancomycin was initially measured with a particle-enhanced turbidimetric inhibition immunoassay. Free vancomycin present in the patient’s specimen competes with particle-bound vancomycin for drug-specific antibody binding sites, thereby inhibiting antibody-mediated particle aggregation. The rate and amount of particle aggregation are inversely proportional to the amount of vancomycin present in the patient’s specimen.

Both patients had high concentrations of monoclonal immunoglobulins, also called paraproteins, in their serum, which, as noted by the manufacturer, may potentially interfere. Paraproteins can promote aggregation via nonspecific mechanisms (aggregation not mediated by antivancomycin antibodies), which can lead to falsely low results, as seen for patient A, or error codes indicating aggregation rates that exceed those expected even in the absence of vancomycin, as seen for patient B.

When unexpectedly low drug concentrations or abnormally high reaction rates are detected, one can test for the presence of a nonspecific aggregator by mixing the specimen with an equal amount of a serum pool with a known vancomycin concentration. The measurement of a concentration that is substantially less than the mean of the 2 specimens suggests the presence of a nonspecific aggregator. After mixing the specimen from patient A with an equal volume of patient pool containing vancomycin, the apparent concentration was far less than expected. It is important to note that when a 1:1 mix was prepared using the manufacturer’s control (30.4 mg/L) instead of the patient pool, near complete recovery was observed. This result was most likely due to a matrix effect attributable to ethylene glycol in the Beckman control, which, we hypothesize, inhibits nonspecific aggregation, but does not affect antibody-mediated aggregation. Under less suspicious circumstances, the second mix might have been misinterpreted as confirmation of a subtherapeutic concentration, leaving the presence of a nonspecific aggregator undetected.

The specimens from both patients were subsequently measured by using assays that did not depend on particle aggregation and yielded concentrations that were not only consistent with the patients’ renal function and dosing regimens, but were also within the traditional target range of 5–10 mg/L for trough specimens. We also attempted to separate the interference from the patient samples by using ultrafiltration with a 100-kDa molecular weight cutoff filter. For both patient samples, filtration enabled detection of vancomycin in the patient samples and in 1:1 mixes, with the patient pool containing vancomycin (data not shown). This result provides strong evidence for a high–molecular-weight nonspecific aggregator in the patient samples, consistent with the IgM paraprotein in each sample.

what other laboratory tests might demonstrate interferences for these patients?
Paraproteins can cause interference in other clinical assays through a few common mechanisms: production of turbidity in the specimen during the course of reaction or analysis, binding of the paraprotein to a component of the assay system, or binding of the paraprotein to the analyte itself. However, paraprotein interference is relatively uncommon. IgM proteins are the largest and most polyvalent immunoglobulins (molecular weight 900 kDa). As a result, IgM paraproteins cause most reported interferences with chemistry assays, although IgM gammopathies occur least frequently (1).

Paraprotein interference has been documented with glucose, bilirubin (both total and direct), HDL (2), {gamma}-glutamyltransferase, urea, ferritin (1), and many other assays. The 2 incidents we describe appear to be the first reported cases of paraproteinemia interference with a vancomycin assay.

Most clinical assays are formulated to avoid interference by monoclonal immunoglobulins. In addition, most analyzers have software options that can detect anomalous reaction kinetics (e.g., the "reaction rate high" flag that occurred with the sample from patient B) (1). Specimens that do not follow normal reaction patterns can be identified, diluted, and retested. Dilution of patient specimens containing increased concentrations of aggregated paraproteins will often either completely or partially eliminate this type of interference (3). However, even with these protective mechanisms in place, such interferences may not be detected.

Less commonly, a paraprotein may bind the analyte being assayed or a component of the assay system. For example, if the paraprotein preferentially binds to any assay component (e.g., enzymes or antibodies that are part of an assay reaction scheme, or even the test analyte itself), falsely increased or decreased test results can occur (4). This type of interference will not usually be detected by anomalous reaction kinetics but rather when the unexpected result does not fit with the patient’s clinical picture.

Another potential source of assay interference with higher concentrations of IgM is increased specimen viscosity, particularly associated with Waldenström macroglobulinemia. On refrigeration these specimens can become gel-like, and inadequate warming may lead to pipetting errors (5). If the laboratory is aware of the patient’s condition, this temperature-dependent viscosity problem can be avoided.

what are the recommendations for monitoring vancomycin?
Vancomycin is a glycopeptide antibiotic that inhibits cell-wall synthesis and is primarily prescribed for patients with gram-positive infections. Vancomycin is not metabolized, but undergoes renal elimination with a clearance rate that approximates the glomerular filtration rate. As with other therapeutic drug monitoring, serum vancomycin measurements can be used to ensure effective dosing and to prevent toxic drug concentrations.

Despite decades of vancomycin use, there remains considerable debate regarding its toxicity and the necessity of measuring serum concentrations to prevent toxicity. This debate most likely stems from a paucity of studies that relate treatment outcome to serum concentrations in patients without confounding factors such as concurrent aminoglycoside antibiotic therapy. Current guidelines suggest that monitoring of serum concentrations is usually unnecessary in patients with normal renal function and uncomplicated infections being treated with standard doses of vancomycin. Monitoring of trough concentrations is suggested for patients receiving prolonged IV treatment, patients receiving other nephrotoxic drugs, patients who are morbidly obese, patients with an altered volume of distribution, and patients with unpredictable or impaired renal function (6). The traditional target range for trough concentrations is 5–10 mg/L, but recent guidelines have suggested a target trough range of 15–20 mg/L for complicated and hospital-acquired infections (7). There is currently a general consensus that monitoring of peak concentrations is of little benefit (6)(8). In the cases we report, because patient A had normal renal function, monitoring vancomycin was probably not indicated. This conclusion is supported by the finding of a trough concentration within the traditional target range.

patient follow-up
The team caring for patient A opted to wait for results from the outside laboratory rather than make immediate changes to the dosing regimen. Because renal function was normal, no additional testing was requested once the normal results from the outside laboratory were received. In contrast, the team caring for patient B discontinued the drug before the next dose owing to her tenuous renal status. Each case highlights the issues that may be seen with monoclonal gammopathies and the importance of policies to prevent the inappropriate release of inaccurate results.

POINTS TO REMEMBER


Acknowledgments

Author Contributions: All authors confirmed they have contributed to the intellectual content of this paper and have met the following 3 requirements: (a) significant contributions to the conception and design, acquisition of data, or analysis and interpretation of data; (b) drafting or revising the article for intellectual content; and (c) final approval of the published article.

Authors’ Disclosures of Potential Conflicts of Interest: No authors declared any potential conflicts of interest.

Role of Sponsor: The funding organizations played no role in the design of study, choice of enrolled patients, review and interpretation of data, or preparation or approval of manuscript.


References

  1. Bakker AJ, Mücke M. Gammopathy interference in clinical chemistry assays: mechanisms, detection and prevention. Clin Chem Lab Med 2007;45:1240-1243.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]
  2. Yang Y, Howanitz PJ, Howanitz JH, Gorfajn H, Wong K. Paraproteins are a common cause of interferences with automated chemistry methods. Arch Pathol Lab Med 2008;132:217-223.[Web of Science][Medline] [Order article via Infotrieve]
  3. Attaelmannan M, Levinson SS. Understanding and identifying monoclonal gammopathies. Clin Chem 2000;46:1230-1238.[Abstract/Free Full Text]
  4. Yamada K, Yagihashi A, Ishii S, Tanemura K, Kida T, Watanabe N, Niitsu Y. Interference with nephelometric assay of C-reactive protein and antistreptolysin-O by monoclonal IgM-kappa from a myeloma patient [Letter]. Clin Chem 1997;43:2435a-2437a.
  5. Jaleel A, Owen BA, Manske MK, Katzmann JA, Kyle RA, Abraham RS. Bence Jones cryoglobulinuria: characterization of a urinary kappa light chain cryoglobulin [Letter]. Clin Chem 2006;52:1435-1436.[Free Full Text]
  6. Hammett-Stabler CA, Johns T. Laboratory guidelines for monitoring of antimicrobial drugs. National Academy of Clinical Biochemistry. Clin Chem 1998;44:1129-1140.[Abstract/Free Full Text]
  7. . American Thoracic Society, Infectious Disease Society of America. Guidelines for the management of adults with hospital-acquired, ventilator-associated, and healthcare-associated pneumonia. Am J Respir Crit Care Med 2005;171:388-416.[Free Full Text]
  8. Ryback MJ. The pharmacokinetic and pharmacodynamic properties of vancomycin. Clin Infect Dis 2006;42(1 Supp):S35-S39.[CrossRef][Web of Science][Medline] [Order article via Infotrieve]




This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Simons, S. A.
Right arrow Articles by Hoofnagle, A. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Simons, S. A.
Right arrow Articles by Hoofnagle, A. N.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS