Clinical Chemistry Siemens Point of Care - Urinalysis
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 43: 180-181, 1997;
This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (14)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zuccaro, P.
Right arrow Articles by Pacifici, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zuccaro, P.
Right arrow Articles by Pacifici, R.
Related Collections
Right arrow Drug Monitoring and Toxicology
(Clinical Chemistry. 1997;43:180-181.)
© 1997 American Association for Clinical Chemistry, Inc.


Technical Briefs

Interference of Nicotine Metabolites in Cotinine Determination by RIA

Piergiorgio Zuccaroa, Simona Pichini, Ilaria Altieri, Mirella Rosa, Manuela Pellegrini and Roberta Pacifici

Clin. Biochem. Dept., Istituto Superiore di Sanità, V.le Regina Elena 299, 00161 Rome, Italy
a author for correspondence: fax ++ 39 6 4461961

Cotinine (COT), a major metabolite of nicotine (NIC), has been used as a biomarker in many studies of active and passive smoking (1)(2)(3)(4). Methods of analysis for COT in biological fluids include gas chromatography, gas chromatography–mass spectrometry, HPLC, HPLC–mass spectrometry, and immunoassays (5)(6)(7)(8)(9)(10). In particular, the RIA developed for COT and NIC by Langone and Van Vunakis (11) was the method reported by the International Agency for Research on Cancer (IARC) for determination of these analytes in several biological matrices (12)(13).

In the description of the assay (11), no mention was made about cross-reactivity of anti-NIC and anti-COT antibodies with trans-3'-hydroxycotinine (THOC) and cotinine glucuronide (COT-G). Indeed, these two compounds were found to be the most abundant metabolites of NIC in urine of smokers (14). Other studies, however, have investigated the cross-reactivity of the anti-COT antiserum with THOC and other metabolites in an ELISA (15).

The objective of this study was to investigate the cross-reactivity of the anti-COT and anti-NIC antisera with THOC and COT-G in the RIA (11)(12)(13). We also used urine samples from active and passive smokers to compare data from the RIA with data obtained by HPLC.

The rabbit antiserum, (-)[3H]COT, and (-)[3H]NIC were supplied by H. Van Vunakis (Brandeis University, Waltham, MA). The detectable range of measurement from the calibration curve was 0.5–50 µg/L for NIC and 0.2–20 µg/L for COT. The cross-reactivities of the anti-COT and anti-NIC antibodies with NIC metabolites different from THOC and COT-G were reported as <5%. In addition, urine samples of smokers were analyzed for COT and THOC with an HPLC method described by Zuccaro et al. (16). In brief, the method used reversed-phase chromatography with ultraviolet detection (254 nm) to measure NIC metabolites in urine samples that had undergone solid-phase extraction before chromatography. The limit of quantification with this method was 10 µg/L for NIC and 5 µg/L each for COT and THOC, and the assay showed good reproducibility, intra- and interday CVs being <4% for various concentrations of the analytes.

Calibrators for NIC, COT, THOC, and COT-G were prepared at several concentrations in Tris buffer (pH 7.4) and were used in the RIA to calculate inhibition curves by comparison with the calibration curves for COT and NIC. Duplicate or triplicate assays were performed on different days. The relative cross-reactivity was determined as calculated by Abraham (17). In particular, the percent of cross-reaction was calculated from the percent ratio between the concentration (µg/L) of COT (or NIC) and that of the other metabolites required to displace 50% of the (-)[3H]COT [or (-)[3H]NIC] bound to the antiserum.

Stock solutions of NIC, COT, and THOC were prepared in methanol, stored at <0 °C, and used with appropriate dilutions for chromatographic analyses. We also obtained urine samples from 13 smokers and 6 smoke-exposed nonsmokers, stored these at -20 °C, and used aliquots of these samples for both RIA and HPLC analyses. In particular, aliquots used for the RIA were diluted (from 1:50 to 1:400) so as to fall within the range of measurement reported for the assay.

In addition, we added known quantities of COT and THOC to blank urines obtained from nonsmokers who had not been exposed to environmental tobacco smoke. We analyzed these samples by RIA and HPLC to verify the results obtained for the smokers and the smoke-exposed nonsmokers.

The relative cross-reactivities of NIC, COT, THOC, and COT-G with the anti-COT and anti-NIC antisera are reported in Table 1 . Results obtained for NIC and COT confirmed the data in the literature (11). Further, we observed no cross-reactivity of THOC and COT-G at increasing concentrations with anti-NIC antiserum, nor of COT-G with anti-COT antiserum. However, the cross-reactivity of THOC with anti-COT antiserum at 50% inhibition was 34%, high enough to lead to an overestimation of COT in the presence of THOC—as confirmed by the comparison between HPLC and RIA values of COT in blank urine samples with added COT and THOC and in samples from smokers and smoke-exposed nonsmokers (Table 2 ). Moreover, the HPLC and RIA values of blank samples supplemented with similar quantities of THOC and COT correlated highly: r = 0.98 (P = 0.0003) for RIA vs HPLC values for COT, and r = 0.99 (P = 0.0002) for RIA COT vs HPLC COT plus THOC. For samples from the smokers and the exposed nonsmokers, RIA vs HPLC values for COT (r = 0.8, P = 0.00002) and RIA COT vs HPLC COT plus THOC (r = 0.8, P = 0.00001) still correlated, even though the RIA results for high values of THOC differed from the true concentrations of COT and THOC (as measured by HPLC) (Table 2 , subjects 7, 8, 10).


View this table:
[in this window]
[in a new window]
 
Table 1. Relative cross-reactivity of anti-NIC and anti-COT antibodies with NIC metabolites.


View this table:
[in this window]
[in a new window]
 
Table 2. COT and THOC concentrations (µg/L) measured by HPLC and RIA in supplemented urine and in urine from smokers and exposed nonsmokers.

In the recent years, COT has been used in epidemiological screenings as a biomarker to discriminate between active and passive smokers and to quantify the exposure to environmental tobacco smoke (2). Discrimination between active and passive smokers is reasonably easy, the mean concentrations of COT in the former group being as much as 10 times those in the latter. Much more difficult is differentiation between light smokers and highly exposed passive smokers, or between exposed passive smokers and nonexposed nonsmokers; in these subjects the COT values are low and may overlap, approaching cutoff values. For this situation, accuracy and precision of the measurements need to be improved, e.g., by adjusting urinary COT for the urinary creatinine concentration (18) or by using a more sensitive and specific method of detection such as isotope dilution liquid chromatography–tandem mass spectrometry (19) or a monoclonal antibody immunoassay tested for cross-reactivity with THOC.

Indeed, although cross-reactivity of THOC for COT antiserum might be useful from an epidemiological point of view (by indirectly increasing the sensitivity of the COT RIA), it represents an analytical bias, which should be indicated in reports of the characteristics of the assay. In any case, one must take into account the method of COT analysis when choosing the cutoff value to discriminate between exposed and nonexposed nonsmokers, to be able to correctly compare results obtained with methods based on different principles.

Finally, in the present study, we determined the cross-reactivity of THOC by assaying its racemic form, whereas the naturally occurring metabolite is (-)THOC; cross-reactivity of the natural metabolite with anti-COT antiserum, therefore, which is stereospecific (11), can be higher than values reported here.


References

  1. Jarvis M, Tunstall-Pedoe H, Feyerabend C, Vesey C, Salloojee Y. Biochemical markers of smoke absorption and self-reported exposure to passive smoking. J Epidemiol Community Health 1984;38:335-339. [Abstract/Free Full Text]
  2. Wall MA, Johnson J, Jacob P, Benowitz NL. Cotinine in the serum, saliva, and urine of nonsmokers, passive smokers, and active smokers. Am J Public Health 1988;78:699-701. [Abstract/Free Full Text]
  3. Cummings KM, Markello SJ, Mahoney M, Bhargava AK, McElroy PD, Marshall JR. Measurement of current exposure to environmental tobacco smoke. Arch Environ Health 1990;45:74-79. [Web of Science][Medline] [Order article via Infotrieve]
  4. Watts RR, Langone JJ, Knight GJ, Lewtas J. Cotinine Analytical Workshop Report: consideration of analytical methods for determining cotinine in human body fluids as a measure of passive exposure to tobacco smoke. Environ Health Perspect 1990;84:173-182. [Web of Science][Medline] [Order article via Infotrieve]
  5. Feyerabend C, Russell MAH. A rapid gas–liquid chromatographic method for the determination of cotinine and nicotine in biological fluids. J Pharm Pharmacol 1990;42:450-452. [Web of Science][Medline] [Order article via Infotrieve]
  6. Daenens P, Larulle Callewaert K, De Schepper P, Galeazzi R, Van Rossum J. Determination of cotinine in biological fluids by capillary gas chromatography–mass spectrometry–selected ion monitoring. J Chromatogr 1985;342:79-87. [Web of Science][Medline] [Order article via Infotrieve]
  7. Pichini S, Altieri I, Pacifici R, Rosa M, Zuccaro P. Elimination of caffeine interference in high performance liquid chromatographic determination of cotinine in human plasma. J Chromatogr 1991;568:267-269. [Web of Science][Medline] [Order article via Infotrieve]
  8. Pacifici R, Pichini S, Altieri I, Rosa M, Bacosi A, Caronna A, Zuccaro P. Determination of nicotine and two major metabolites in serum by high-performance liquid chromatography, and high-performance liquid chromatography–particle beam mass spectrometry. J Chromatogr 1993;612:209-213. [Web of Science][Medline] [Order article via Infotrieve]
  9. Langone JJ, Bjercke RJ. Idiotype–anti-idiotype hapten immunoassays: assay for cotinine. Anal Biochem 1989;182:187-192. [Web of Science][Medline] [Order article via Infotrieve]
  10. Benkirane S, Nicolas A, Galteau MM, Siest G. Highly sensitive immunoassays for the determination of cotinine in serum and saliva. Comparison between RIA and an avidin–biotin ELISA. Eur J Clin Chem Clin Biochem 1991;29:405-410. [Web of Science][Medline] [Order article via Infotrieve]
  11. Langone JJ, Van Vunakis H. Radioimmunoassay of nicotine, cotinine, and gamma-(3-pyridyl)-gamma-oxo-N-methylbutyramide. Methods Enzymol 1982;84:628-640. [Web of Science][Medline] [Order article via Infotrieve]
  12. Van Vunakis H, Gijka HB, Langone JJ. Radioimmunoassay for nicotine and cotinine. O'Neil IK Brunnemann KD Dodet B Hoffmann D eds. Environmental carcinogens—methods of analysis and exposure measurement 1987;Vol. 9:317-330 International Agency for Research on Cancer Lyon. .
  13. Van Vunakis H, Gijka HB, Langone JJ. Radioimmunoassay for nicotine and cotinine. Seifert B van de Wiel HJ Dodet B O'Neill IK eds. Environmental carcinogens—methods of analysis and exposure measurement 1993;Vol. 12:293-299 International Agency for Research on Cancer Lyon. .
  14. Byrd GD, Chang K, Greene JM, deBethizy JD. Evidence for urinary excretion of glucuronide conjugates of nicotine, cotinine, and trans-3'-hydroxycotinine in smokers. Drug Metab Dispos 1991;20:192-197. [Abstract]
  15. Schepers G, Walk RA. Cotinine determination by immunoassays may be influenced by other nicotine metabolites. Arch Toxicol 1988;62:395-397. [Web of Science][Medline] [Order article via Infotrieve]
  16. Zuccaro P, Altieri I, Rosa M, Passa AR, Pichini S, Pacifici R. Solid-phase extraction of nicotine and its metabolites for high-performance liquid chromatographic determination in urine. J Chromatogr 1995;668:187-188. [Medline] [Order article via Infotrieve]
  17. Abraham GE. Solid-phase radioimmunoassay of estradiol-17ß. J Clin Endocrinol Metab 1969;29:866-870. [Free Full Text]
  18. Thompson SG, Barlow RD, Wald NJ, Van Vunakis H. How should urinary cotinine concentrations be adjusted for urinary creatinine concentration?. Clin Chim Acta 1990;187:289-296. [Web of Science][Medline] [Order article via Infotrieve]
  19. Preliminary data. Exposure of persons aged >=4 years to tobacco smoke—United States, 1988–1991. MMWR 1993;42:37–9..



The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
T. R. Gray, R. Magri, D. M. Shakleya, and M. A. Huestis
Meconium Nicotine and Metabolites by Liquid Chromatography-Tandem Mass Spectrometry: Differentiation of Passive and Nonexposure and Correlation with Neonatal Outcome Measures
Clin. Chem., December 1, 2008; 54(12): 2018 - 2027.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
P. Jatlow, S. McKee, and S. S. O'Malley
Correction of Urine Cotinine Concentrations for Creatinine Excretion: Is It Useful?
Clin. Chem., November 1, 2003; 49(11): 1932 - 1934.
[Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (14)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zuccaro, P.
Right arrow Articles by Pacifici, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zuccaro, P.
Right arrow Articles by Pacifici, R.
Related Collections
Right arrow Drug Monitoring and Toxicology


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS