Clinical Chemistry 50: 537-544, 2004. First published January 6, 2004; 10.1373/clinchem.2003.019653
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2003.019653v1
50/3/537    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (8)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Poller, L.
Right arrow Articles by Jespersen, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Poller, L.
Right arrow Articles by Jespersen, J.
Related Collections
Right arrow Laboratory Management
Right arrow Hemostasis and Thrombosis
(Clinical Chemistry. 2004;50:537-544.)
© 2004 American Association for Clinical Chemistry, Inc.


Hemostasis and Thrombosis

European Concerted Action on Anticoagulation. Quality Assessment of the CoaguChek Mini and TAS PT-NC Point-of-Care Whole-Blood Prothrombin Time Monitors

Leon Poller1,1,a, Michelle Keown1, Nikhil Chauhan1, Anton M.H.P. van den Besselaar2,1, Armando Tripodi3,1, Caroline Shiach4,1 and Jorgen Jespersen5,1

1 European Concerted Action on Anticoagulation Central Facility, School of Biological Sciences, The University of Manchester, Manchester, United Kingdom. 2 Haemostasis and Thrombosis Research Centre, Leiden University Medical Center, Leiden, The Netherlands. 3 A Bianchi Bonomi, Haemophilia and Thrombosis Centre, IRCCS Maggiore Hospital, University of Milan, Milan, Italy. 4 Department of Haematology, Manchester Royal Infirmary, Oxford Road, Manchester, United Kingdom. 5 Department for Thrombosis Research, University of Southern Denmark and Department of Clinical Biochemistry, Ribe County Hospital, Esbjerg, Denmark.

aAddress correspondence to this author at: ECAA Central Facility, School of Biological Sciences, The University of Manchester, Manchester M13 9PT, United Kingdom. Fax 44-161-275-5316; e-mail ecaa{at}man.ac.uk.

Background: International Normalized Ratios (INRs) for prothrombin time obtained with the CoaguChek Mini and TAS (RapidPointCoag) PT-NC systems are markedly different and also differ from the "true" INR. There is therefore a need for local quality assessment (QA) of the two systems.

Methods: A set of 60 lyophilized artificially depleted and 60 lyophilized coumarin plasmas were tested at 10 centers on both point-of-care testing monitors. Subsets of three and five plasmas were selected as QA plasmas and compared with the remaining 55 to assess the relative ability of the systems to characterize performance at the individual centers. The incidence of aberrant results (outliers; >15% deviation from the true INR) was also recorded. The expected incidence with the QA plasmas was calculated and compared.

Results: On both systems, INR with the common sets of 55 lyophilized plasmas varied considerably between centers. With the TAS PT-NC, subsets of five and three European Concerted Action on Anticoagulation (ECAA) artificially depleted plasmas gave good correlation with the 55 plasmas, but the coumarin plasmas performed less well. With the CoaguChek Mini, correlation was good with sets of five artificially depleted QA plasmas and reasonable with three but was less satisfactory with the coumarin plasmas. Outliers were detected with both types of plasmas on both test systems but with variable success.

Conclusions: With the TAS PT-NC, three ECAA artificially depleted lyophilized plasmas provided reliable QA, but five lyophilized coumarin plasmas were required. With the CoaguChek Mini, five artificially depleted plasmas gave reliable QA but coumarin plasmas gave poorer results. ECAA QA plasmas provide a local system for checking INRs obtained with monitors of both types.




The following articles in journals at HighWire Press have cited this article:


Home page
Eur Heart JHome page
R. De Caterina, S. Husted, L. Wallentin, G. Agnelli, F. Bachmann, C. Baigent, J. Jespersen, S. D. Kristensen, G. Montalescot, A. Siegbahn, et al.
Anticoagulants in heart disease: current status and perspectives
Eur. Heart J., April 10, 2007; (2007) ehl492v1.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
L. Poller, M. Keown, S. A. Ibrahim, F. J.M. van der Meer, A. M.H.P. van den Besselaar, A. Tripodi, J. Jespersen, European Action on Anticoagulation, P. Meijer, C. Kluft, et al.
Quality Assessment of CoaguChek Point-of-Care Prothrombin Time Monitors: Comparison of the European Community-Approved Procedure and Conventional External Quality Assessment.
Clin. Chem., October 1, 2006; 52(10): 1843 - 1847.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Association for Clinical Chemistry.