Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 51: 1612-1618, 2005. First published July 21, 2005; 10.1373/clinchem.2004.046599
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Data Supplement
Right arrow All Versions of this Article:
clinchem.2004.046599v1
51/9/1612    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Web of Science (2)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gromek, K.
Right arrow Articles by Kaczorowski, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gromek, K.
Right arrow Articles by Kaczorowski, T.
Related Collections
Right arrow Molecular Diagnostics and Genetics
(Clinical Chemistry. 2005;51:1612-1618.)
© 2005 American Association for Clinical Chemistry, Inc.


Molecular Diagnostics and Genetics

DNA Sequencing by Indexer Walking

Katarzyna Gromek1 and Tadeusz Kaczorowskia,1

1 Department of Microbiology, University of Gdansk, Gdansk, Poland.

aAddress correspondence to this author at: Department of Microbiology, University of Gdask, Gdask 80-822, Kladki 24, Poland. Fax 48-58-320-2031; e-mail kaczorow{at}biotech.univ.gda.pl.

Background: There is a need for DNA sequencing methods that are faster, more accurate, and less expensive than existing techniques. Here we present a new method for DNA analysis by means of indexer walking.

Methods: For DNA sequencing by indexer walking, we ligated double-stranded synthetic oligonucleotides (indexers) to DNA fragments that were produced by type IIS restriction endonucleases, which generate nonidentical 4-nucleotide 5' overhangs. The subsequent amplification (30 thermal cycles) of indexed DNA provided a template for automated DNA sequencing with fluorescent dideoxy terminators. The data gathered in the first sequencing reaction permitted further movement into the unknown nucleotide sequence by digestion of analyzed DNA with selected type IIS restriction endonuclease followed by ligation of the next indexer. A library of presynthesized indexers consisting of 256 oligonucleotides was used for bidirectional analysis of DNA molecules and provided universal primers for sequencing.

Results: The proposed protocol was successfully applied to sequencing of cryptic plasmids isolated from pathogenic strains of Escherichia coli. The overall error rate for base-calling was 0.5%, with a mean read length of 550 nucleotides. Approximately 1000 nucleotides of high-quality sequence could be obtained per day from a single clone.

Conclusions: Indexer walking can be used as a low-cost procedure for nucleotide sequence determination of DNA molecules, such as natural plasmids, cDNA clones, and longer DNA fragments. It can also serve as an alternative method for gap filling at the final stage of genome sequencing projects.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the American Association for Clinical Chemistry.