Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 54: 1158-1165, 2008. First published May 16, 2008; 10.1373/clinchem.2007.101733
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Supplemental Data
Right arrow All Versions of this Article:
clinchem.2007.101733v1
54/7/1158    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Whitfield, J. B.
Right arrow Articles by Montgomery, G. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Whitfield, J. B.
Right arrow Articles by Montgomery, G. W.
Related Collections
Right arrow Proteomics and Protein Markers
(Clinical Chemistry. 2008;54:1158-1165.)
© 2008 American Association for Clinical Chemistry, Inc.


Proteomics and Protein Markers

Measuring Carbohydrate-Deficient Transferrin by Direct Immunoassay: Factors Affecting Diagnostic Sensitivity for Excessive Alcohol Intake

John B. Whitfield1,2,a, Veronica Dy2, Pamela A.F. Madden3, Andrew C. Heath3, Nicholas G. Martin1 and Grant W. Montgomery1

1 Genetic Epidemiology Unit, Queensland Institute of Medical Research, Brisbane, Australia; 2 Biochemistry Department, Royal Prince Alfred Hospital, Sydney, Australia; 3 Midwest Alcoholism Research Center, Washington University, St. Louis, MO.

aAddress correspondence to this author at: Genetic Epidemiology Unit, Queensland Institute of Medical Research, PO Royal Brisbane Hospital, Queensland 4029, Australia. Fax 61-7-3362-0101; e-mail John.Whitfield{at}qimr.edu.au.

Background: Carbohydrate-deficient transferrin (CDT) is a marker of alcohol intake that is used for detecting or monitoring alcohol-use disorders. The introduction of a new direct immunoassay for CDT justifies reevaluation of test performance and reexamination of factors affecting test diagnostic sensitivity and specificity.

Methods: Individuals enrolled in twin/family studies of alcohol use and dependence provided blood samples and information on recent alcohol use. Serum CDT concentration was measured in 2 088 people with the N Latex CDT (Dade Behring) method, and CDT percentage (CDT%) was calculated as the proportion of the total transferrin concentration measured with Roche reagents.

Results: Diagnostic sensitivity was low, both for comparisons of men who reported an alcohol intake of >28 drinks/week vs those who consumed ≤28 drinks/week (28% sensitivity) and for women who consumed >14 drinks/week vs those who consumed ≤14 drinks/week (18% sensitivity), at cutoff values that yielded a 95% specificity. Body mass index, variables associated with metabolic syndrome, and smoking had notable effects on the probability of an abnormal CDT result with excessive alcohol use. Diagnostic sensitivity was greater in men of normal weight (43%) than in obese men (10%) and greater in male smokers (38%) than in male nonsmokers (21%). In women, diagnostic sensitivities were ≤20%, even for those of normal weight and for smokers.

Conclusions: CDT is a poor marker of excessive alcohol intake in both women and men who are overweight or obese. It is also less useful in nonsmokers than in smokers. The diagnostic performance of the direct immunoassay and the effects of obesity and smoking are similar to those reported with previous anion-exchange immunoassay methods.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the American Association for Clinical Chemistry.