Background: The aim of this study was to compare the clinical performance of 2 sensitive cTnI assays with 10% CV imprecision below the 99th percentile upper reference limit.
Methods: We measured cardiac troponin and N-terminal pro-brain natriuretic peptide (NT-proBNP) concentrations in a random sample of the Global Use of Strategies To Open Occluded Coronary Arteries (GUSTO) IV cohort (n = 1251). Outcome data of 1-year mortality and the composite endpoint DMI [death and/or myocardial infarction (MI) within 30 days] were available in all patients. The 99th percentile of a healthy population was estimated from the Sweden Women and Men and Ischemic Heart Disease (SWISCH) cohort (n = 442). We measured cardiac troponin I (cTnI) using the Access AccuTnI (Beckman Coulter) and Centaur TnI Ultra (Siemens Healthcare Diagnostics) and NT-proBNP using the Elecsys 2010 (Roche Diagnostics).
Results: Applying the 10% CV cutoff, the sensitivity of the Access AccuTnI assay in identifying DMI and death was higher than that of the Centaur TnI Ultra (P = 0.02 and P < 0.001), and the AccuTnI assay also identified more patients at risk (P < 0.001) and with poor outcome. Applying the 99th percentile cutoffs, AccuTnI identified more patients at risk than the Centaur TnI (P < 0.001) and with significant differences in outcome. Significantly more patients with cardiac troponins below the cutoffs as measured by Centaur TnI had increased NT-proBNP concentrations (P < 0.001) compared with AccuTnI.
Conclusions: The AccuTnI assay identified more patients at risk than the Centaur cTnI Ultra assay. Our results demonstrate the clinical potential of high-sensitivity cardiac troponin assays for the identification of patients at risk of dying from cardiovascular disease.
The following articles in journals at HighWire Press have cited this article:
![]() |
T. Keller, T. Zeller, D. Peetz, S. Tzikas, A. Roth, E. Czyz, C. Bickel, S. Baldus, A. Warnholtz, M. Frohlich, et al. Sensitive Troponin I Assay in Early Diagnosis of Acute Myocardial Infarction N. Engl. J. Med., August 27, 2009; 361(9): 868 - 877. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Kuhn, T. Addona, H. Keshishian, M. Burgess, D.R. Mani, R. T. Lee, M. S. Sabatine, R. E. Gerszten, and S. A. Carr Developing Multiplexed Assays for Troponin I and Interleukin-33 in Plasma by Peptide Immunoaffinity Enrichment and Targeted Mass Spectrometry Clin. Chem., June 1, 2009; 55(6): 1108 - 1117. [Abstract] [Full Text] [PDF] |
||||