Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 0: 200302268, 2003; 10.1373/clinchem.2003.022681
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
clinchem.2003.022681v1
49/12/2056    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, B.-L.
Right arrow Articles by Ong, C.-N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, B.-L.
Right arrow Articles by Ong, C.-N.

Received on June 25, 2003
Accepted on September 9, 2003

Automation and Analytical Techniques

Simultaneous Determination of Tocotrienols, Tocopherols, Retinol, and Major Carotenoids in Human Plasma

Bee-Lan Lee 1, Ai-Li New 1, Choon-Nam Ong 1*

1 Department of Community, Occupational and Family Medicine, Faculty of Medicine, National University of Singapore, Singapore 117597

* To whom correspondence should be addressed. E-mail: cofongcn{at}nus.edu.sg.

Background: Epidemiologic evidence suggests that the concentrations of antioxidant vitamins in human plasma may play an important role in numerous chronic diseases, such as cancer and cardiovascular disease. However, methods for simultaneous measurement of these antioxidants are scarce. We developed and validated a new HPLC method for simultaneous determination of these vitamers in human plasma that uses a novel column-switching approach.

Methods: The new method uses liquid-liquid extraction and isocratic separation with two monomeric C18 columns maintained at 35 and 4 °C coupled with ultraviolet-visible and fluorometric detection. This method could separate 14 vitamers and 3 internal standards within 27 min. No additional modifier was required; the mobile phase was acetonitrile-methanol (65:35 by volume), and the flow rate was 1 mL/min.

Results: For photodiode array detection, the detection limits (signal-to-noise ratio >3) were 0.02 mg/L for {beta}-carotene, lutein, zeaxanthin, and canthaxanthin; 0.01 mg/L for all-trans-retinol, {beta}-cryptoxanthin, {alpha}-carotene, and lycopene; and 0.1 mg/L for all tocopherols and tocotrienols. The detection limit was at least 25-fold lower (0.004 mg/L) when fluorometry was used for measurement of {delta}-, {gamma}-, and {alpha}-tocotrienol and {delta}-tocopherol compared with ultraviolet detection. The recovery and imprecision of the assay were generally >90% and <10%, respectively.

Conclusions: This new method separates a wide range of fat-soluble antioxidant vitamins in human plasma, including six carotenoids, three isoforms of tocotrienols and tocopherols ({delta}-, {gamma}-, and {alpha}-), and all-trans-retinol. The overall findings suggest that our method is faster, more sensitive, and more comprehensive than existing methods.© 2003 American Association for Clinical Chemistry




The following articles in journals at HighWire Press have cited this article:


Home page
JNCI J Natl Cancer InstHome page
J.-M. Yuan, Y.-T. Gao, C.-N. Ong, R. K. Ross, and M. C. Yu
Prediagnostic level of serum retinol in relation to reduced risk of hepatocellular carcinoma.
J Natl Cancer Inst, April 5, 2006; 98(7): 482 - 490.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Copyright © 2003 by the American Association for Clinical Chemistry.